H. Kim

H. Kim

Auto-generated profile, based on publicly available information

H. Kim

Radiation Monitoring Devices, Inc., Watertown, MA, Canada

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2025 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MSM. S. Squillante
M. S. Squillante
MBM. J. Breen
M. J. Breen
JCJ. F. Christian
J. F. Christian
AKA. Kargar
A. Kargar
YOY. Ogorodnik
Y. Ogorodnik
CSC. Scott
C. Scott
The detector that converts X-ray intensity into a digitized electronic signal, processed into an image, often limits the performance of modern X-ray imaging systems, whether for medical, research, or industrial applications. Digital radiography (DR) uses the following two types of detectors: 1) indirect detectors, where a scintillating film converts X-rays into an optical signal read by an optical detector, and 2) direct detectors using semiconductors. Semiconductor X-ray detector technology typically uses a silicon wafer, an amorphous selenium (a-Se) film, or a relatively thin cadmium zinc telluride (CZT) crystal bump bonded to a readout platform. Although the use of a-Se and CZT improves the attenuation coefficient beyond that of silicon, a further increase in performance is highly desirable for improved imaging of higher-energy X-rays (greater than 20 keV). This article presents results on thallium bromide (TlBr) films coupled to a read-out integrated circuit (ROIC). TlBr, an attractive material for hard X-ray imaging due to its high atomic number and high density, achieves an image resolution of $20 \mu $ m as a 1 cm ${}^{2} \times 100$ - $\mu $ m-thick columnar film deposited on CMOS ROIC.

12 October 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
ABA.E. Bolotnikov
A.E. Bolotnikov
CBC.A. Brown
C.A. Brown
GCG.A. Carini
G.A. Carini
JCJ. Christian
J. Christian
LCL. Cirignano
L. Cirignano
KSK.S. Shah
K.S. Shah

1 May 2026 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
JCJ. F. Christian
J. F. Christian
MSM. S. Squillante
M. S. Squillante
MBM. J. Breen
M. J. Breen
OMO. Maksimov
O. Maksimov
HKH. Kim
H. Kim
MSM. R. Squillante
M. R. Squillante
This work explores the fabrication and characterization of X-ray imaging devices using a single-crystal TlBr sample (8 mm × 8 mm × 10 mm) and polycrystalline TlBr film (approximately 0.38-mm thick), both bonded to a Libra-1 Complementary Metal-Oxide-Semiconductor (CMOS) readout chip connected to the BrillianSe 1M readout system. The BrillianSe 1M, designed for X-ray radiography by KA Imaging, features a 10 mm × 11 mm readout chip with a 7.8 μm pixel pitch and a 7.8 mm × 7.8 mm active area. The work below describes the characterization of test and imaging devices. The characterization includes current-voltage (IV) curves and impedance spectra, longevity measurements of the X-ray response and leakage current, and imaging characterization with light-emitting diodes (LED) and X-rays. The resistivity of 3x1010 Ω-cm was estimated for a polycrystalline film sample. Following five weeks, the leakage current decreased from 670 to 6.4 nA, while the X-ray photocurrent decreased from 28 to 4 nA. Both the single crystal and polycrystalline imaging devices resolved 0.3-mm-diameter holes in a Tungsten composite mask when irradiated with 90 kVp (100 μA tube current) X-rays. Effects at the interface can be seen with both LED and X-rays. The images provide critical information for optimizing the fabrication process and device longevity.