Meng Wang

Meng Wang

Auto-generated profile, based on publicly available information

Meng Wang

Rensselaer Polytechnic Institute, Troy, NY, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
JZJunbo Zhao
Junbo Zhao
LMLamine Mili
Lamine Mili
MWMeng Wang
Meng Wang
This paper develops a generalized framework that allows us to investigate the vulnerability of the power system nonlinear state estimator to false data injection attacks (FDIAs) from the operator's perspective and to initiate some countermeasures. Unlike most existing FDIA methods, which assume a perfect knowledge of the system measurements and topology by a hacker, we derive and analyze the uncertainties for launching successful FDIAs along with their upper bounds. To effectively defense against an FDIA, we propose a robust detector that checks the measurement statistical consistency using a subset of secure PMU measurements. We first show that if these secure PMU measurements are free of bad data while making the system observable, the FDIA is detectable. We then show that detectability is also ensured if these conditions are relaxed while using alternative redundant measurements from short-term nodal synchrophasor predictions together with the robust Huber M-estimator. Numerical simulation results on the IEEE 30-bus and 118-bus systems demonstrate the effectiveness and robustness of the proposed method.

20 May 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
WLWenting Li
Wenting Li
DDDeepjyoti Deka
Deepjyoti Deka
MCMichael (Misha) Chertkov
Michael (Misha) Chertkov
MWMeng Wang
Meng Wang
Diverse fault types, fast reclosures, and complicated transient states after a fault event make real-time fault location in power grids challenging. Existing localization techniques in this area rely on simplistic assumptions, such as static loads, or require much higher sampling rates or total measurement availability. This paper proposes a faulted line localization method based on a convolutional neural network (CNN) classifier using bus voltages. Unlike prior data-driven methods, the proposed classifier is based on features with physical interpretations that improve the robustness of the location performance. The accuracy of our CNN-based localization tool is demonstrably superior to other machine learning classifiers in the literature. To further improve the location performance, a joint phasor measurement units placement strategy are proposed and validated against other methods. A significant aspect of our methodology is that under very low observability ( ${7\%}$ of buses), the algorithm is still able to localize the faulted line to a small neighborhood with high probability. The performance of our scheme is validated through simulations of faults of various types in the IEEE 39-bus and 68-bus power systems under varying uncertain conditions, system observability, and measurement quality.

25 June 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
YHYingshuai Hao
Yingshuai Hao
MWMeng Wang
Meng Wang
JCJoe H. Chow
Joe H. Chow
EFEvangelos Farantatos
Evangelos Farantatos
MPMahendra Patel
Mahendra Patel
This paper presents a new framework to improve the quality of streaming synchrophasor measurements with the existence of missing data and bad data. The method exploits the low-rank property of the Hankel structure to identify and correct bad data, as well as to estimate and fill in missing data. The method is advantageous compared to existing methods in the literature that only estimate missing data by leveraging the low-rank property of the synchrophasor data observation matrix. The proposed algorithm can efficiently differentiate event data from bad data, even in the existence of simultaneous and consecutive bad data. The algorithm has been verified through numerical experiments on a recorded synchrophasor dataset.

25 October 2022 in IEEE Transactions on Information Forensics and Security
Verified
Journal Article
Closed access
EHEhsan Hallaji
Ehsan Hallaji
Roozbeh Razavi-FarRoozbeh Razavi-Far
Roozbeh Razavi-Far
MWMeng Wang
Meng Wang
Mehrdad SaifMehrdad Saif
Mehrdad Saif
BFBruce Fardanesh
Bruce Fardanesh
This paper presents a novel data-driven framework to aid in system state estimation when the power system is under unobservable false data injection attacks. The proposed framework dynamically detects and classifies false data injection attacks. Then, it retrieves the control signal using the acquired information. This process is accomplished in three main modules, with novel designs, for detection, classification, and control signal retrieval. The detection module monitors historical changes of phasor measurements and captures any deviation pattern caused by an attack on a complex plane. This approach can help to reveal characteristics of the attacks including the direction, magnitude, and ratio of the injected false data. Using this information, the signal retrieval module can easily recover the original control signal and remove the injected false data. Further information regarding the attack type can be obtained through the classifier module. The proposed ensemble learner is compatible with harsh learning conditions including the lack of labeled data, concept drift, concept evolution, recurring classes, and independence to external updates. The proposed novel classifier can dynamically learn from data and classify attacks under all these harsh learning conditions. The introduced framework is evaluated w.r.t. real-world data captured from the Central New York Power System. The obtained results indicate the efficacy and stability of the proposed framework.

23 January 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
WLWenting Li
Wenting Li
MWMeng Wang
Meng Wang
JCJoe H. Chow
Joe H. Chow
This paper proposes a data-driven real-time event identification method based on the measurements of Phasor Measurement Units (PMUs). The central idea is to characterize an event by the low-dimensional subspace spanned by the dominant singular vectors of a data matrix that contains spatial-temporal blocks of PMU data. The subspace representation is robust to system initial conditions and characterizes the system dynamics. A dictionary of subspaces that correspond to different events are established off-line, and an event is identified online with the most similar event in the dictionary through subspace comparison. The compact subspace representation reduces the dictionary size and the computational time of the event identification method. Numerical experiments on both simulated events in an IEEE 68-bus power system and the recorded data in New England validate the proposed method.

8 March 2019 in IEEE Transactions on Signal Processing
Verified
Journal Article
Closed access
SZShuai Zhang
Shuai Zhang
MWMeng Wang
Meng Wang
This paper studies the robust matrix completion (RMC) problem with the objective to recover a low-rank matrix from partial observations that may contain significant errors. If all the observations in one column are erroneous, existing RMC methods can locate the corrupted column at best but cannot recover the actual data in that column. Low-rank Hankel matrices characterize the additional correlations among columns besides the low-rankness and exist in power system monitoring, magnetic resonance imaging (MRI) imaging, and array signal processing. Exploiting the low-rank Hankel property, this paper develops an alternating-projection-based fast algorithm to solve the nonconvex RMC problem. The algorithm converges to the ground-truth low-rank matrix with a linear rate even when all the measurements in a constant fraction of columns are corrupted. The required number of observations is significantly less than the existing bounds for the conventional RMC. Numerical results are reported to evaluate the proposed algorithm.