Alexander Poellinger

Alexander Poellinger

Auto-generated profile, based on publicly available information

Alexander Poellinger

Charité, Universitätsmedizin Berlin, Department of Radiology, Augustenburger Platz 1, 13353 Berlin, Germany

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2011 in Radiology
Verified
Journal Article
Closed access
APAlexander Poellinger
Alexander Poellinger
SBSusen Burock
Susen Burock
DGDirk Grosenick
Dirk Grosenick
AHAxel Hagen
Axel Hagen
LLLutz Lüdemann
Lutz Lüdemann
PSPeter-Michael Schlag
Peter-Michael Schlag
To assess early- and late-fluorescence near-infrared imaging, corresponding to the vascular (early-fluorescence) and extravascular (late-fluorescence) phases of indocyanine green (ICG) enhancement, for breast cancer detection and benign versus malignant breast lesion differentiation. The study was approved by the ethical review board; all participants provided written informed consent. Twenty women with 21 breast lesions were examined with near-infrared imaging before, during, and after intravenous injection of ICG. Absorption and fluorescence projection mammograms were recorded simultaneously on a prototype near-infrared imaging unit. Two blinded readers independently assessed the images and assigned visibility scores to lesions seen on the absorption and absorption-corrected fluorescence mammograms. Imaging results were compared with histopathologic findings. Lesion contrast and diameter on the fluorescence mammograms were measured, and Cohen κ, Mann-Whitney U, and Spearman ρ tests were conducted. The absorption-corrected fluorescence ratio mammograms showed high contrast (contrast value range, 0.25-0.64) between tumors and surrounding breast tissue. Malignant lesions were correctly defined in 11 (reader 1) and 12 (reader 2) of 13 cases, and benign lesions were correctly defined in six (reader 1) and five (reader 2) of eight cases with late-fluorescence imaging. Lesion visibility scores for malignant and benign lesions were significantly different on the fluorescence ratio mammograms (P = .003) but not on the absorption mammograms (P = .206). Mean sensitivity and specificity reached 92% ± 8 (standard error of mean) and 75% ± 16, respectively, for fluorescence ratio imaging compared with 100% ± 0 and 25% ± 16, respectively, for conventional mammography alone. Preliminary data suggest that early- and late-fluorescence ratio imaging after ICG administration can be used to distinguish malignant from benign breast lesions.

31 December 2008 in Academic Radiology
Verified
Journal Article
Closed access
APAlexander Poellinger
Alexander Poellinger
JMJan C. Martin
Jan C. Martin
SPSteven L. Ponder
Steven L. Ponder
TFTorsten Freund
Torsten Freund
BHBernd Hamm
Bernd Hamm
FDFelix Diekmann
Felix Diekmann

1 November 2011 in Investigative Radiology
Verified
Journal Article
Closed access
APAlexander Poellinger
Alexander Poellinger
TPThorsten Persigehl
Thorsten Persigehl
MMMarianne Mahler
Marianne Mahler
MBMalte Bahner
Malte Bahner
SPSteven L. Ponder
Steven L. Ponder
TMThomas Moesta
Thomas Moesta
To evaluate the efficacy of the near-infrared (NIR) dye Omocianine in a placebo-controlled, dose-escalating multicenter trial for the detection of malignant breast lesions by using a NIR imaging system. The study was approved by the ethical review board of Berlin and Münster,, and all participants provided written informed consent. Fifty-two consecutive patients were examined with NIR imaging before, during, and after intravenous injection of Omocianine. Three-dimensional absorption and fluorescence diffuse optical tomography scans were recorded simultaneously on a prototype NIR imaging unit (Computed Tomography Laser Mammography, Imaging Diagnostic Systems, Inc., Ft. Lauderdale, FL). Two readers assessed the images in consensus and assigned visibility scores to lesions seen on the absorption and absorption-corrected fluorescence diffuse optical tomography mammograms. Imaging results were compared with histopathologic findings. To analyze whether lesion detection rate for malignant lesions depended on the size of the lesion, lesions were dichotomized into those measuring less than 20 mm and those measuring 20 mm or more. Moreover, the shortest diameter between the center of the target lesions and the skin was measured on axial optical mammography data. There were a total of 53 target lesions. Histopathologically, 22 target lesions were diagnosed as benign and 31 target lesions as malignant. In the absorption mode, a detection rate of 11.8% for benign and 44.4% for malignant lesions across all dose groups was found. In the fluorescence mode, a detection rate of 17.6% was revealed for benign and 55.6% for malignant lesions across all dose groups. For dose group 0.1 mg/kg, a detection rate of 100% was found for malignant lesions in the fluorescence mode and 71.4% in the absorption mode. Across all dose groups in the fluorescence mode, detection rate for malignant target lesions in breasts smaller than the median axial breast diameter of 12.8 cm was higher with 69.2% than in median diameters ≥ 12.8 cm with 46.2%. Omocianine-enhanced fluorescence optical mammography allowed a better detection of more superficially located lesions, with detection rates for a lesion-skin distance <20 mm of 63.6%, for <30 mm of 47.4% and for ≥ 30 mm of 25%. Malignant target lesions with a diameter ≥ 20 mm were slightly better detected with 61.5% in contrast to suspicious lesions <20 mm with 53.8%. Optimal imaging time points varied strongly among the different target lesions and Omocianine dose groups, with a mean optimal time point for malignant lesions at 188 ± 385 minutes. Preliminary data suggest that fluorescence imaging after Omocianine administration has the potential to detect malignant breast lesions. As our study showed considerable variations in the detection of breast cancer at different fluorophore concentrations ranging from 20% to 100%, future work needs to be done to assess the suitable dose for NIR imaging.

1 May 2012 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
FCFederico Collettini
Federico Collettini
MGMascha Golenia
Mascha Golenia
DSDirk Schnapauff
Dirk Schnapauff
APAlexander Poellinger
Alexander Poellinger
Timm DeneckeTimm Denecke
Timm Denecke
BGBernhard Gebauer
Bernhard Gebauer

9 October 2010 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
CSC. Scheurig-Muenkler
C. Scheurig-Muenkler
APA. Poellinger
A. Poellinger
MWMoritz Wagner
Moritz Wagner
BHB. Hamm
B. Hamm
TKThomas J. Kroencke
Thomas J. Kroencke

27 September 2011 in European Radiology
Verified
Journal Article
Closed access
PDF file
FCF. Collettini
F. Collettini
JMJ. C. Martin
J. C. Martin
FDF. Diekmann
F. Diekmann
EFE. Fallenberg
E. Fallenberg
FEF. Engelken
F. Engelken
APA. Poellinger
A. Poellinger