Pablo Artal

Pablo Artal

Auto-generated profile, based on publicly available information

Pablo Artal

Laboratorio de Óptica, Universidad de Murcia, Murcia, Spain

Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2002 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
PAPablo Artal
Pablo Artal
EBEsther Berrio
Esther Berrio
AGAntonio Guirao
Antonio Guirao
PPPatricia Piers
Patricia Piers
We studied the age dependence of the relative contributions of the aberrations of the cornea and the internal ocular surfaces to the total aberrations of the eye. We measured the wave-front aberration of the eye with a Hartmann–Shack sensor and the aberrations of the anterior corneal surface from the elevation data provided by a corneal topography system. The aberrations of the internal surfaces were obtained by direct subtraction of the ocular and corneal wave-front data. Measurements were obtained for normal healthy subjects with ages ranging from 20 to 70 years. The magnitude of the RMS wave-front aberration (excluding defocus and astigmatism) of the eye increases more than threefold within the age range considered. However, the aberrations of the anterior corneal surface increase only slightly with age. In most of the younger subjects, total ocular aberrations are lower than corneal aberrations, while in the older subjects the reverse condition occurs. Astigmatism, coma, and spherical aberration of the cornea are larger than in the complete eye in younger subjects, whereas the contrary is true for the older subjects. The internal ocular surfaces compensate, at least in part, for the aberrations associated with the cornea in most younger subjects, but this compensation is not present in the older subjects. These results suggest that the degradation of the ocular optics with age can be explained largely by the loss of the balance between the aberrations of the corneal and the internal surfaces.

1 May 2001 in Journal of Vision
Verified
Journal Article
Open access
PDF file
PAPablo Artal
Pablo Artal
AGAntonio Guirao
Antonio Guirao
EBEsther Berrio
Esther Berrio
DWDavid R. Williams
David R. Williams
The objective was to study the relative contribution of the optical aberrations of the cornea and the internal ocular optics (with the crystalline lens as the main component) to overall aberrations in the human eye. Three sets of wave-front aberration data were independently measured in the eyes of young subjects: for the anterior surface of the cornea, the complete eye, and internal ocular optics. The amount of aberration of both the cornea and internal optics was found to be larger than for the complete eye, indicating that the first surface of the cornea and internal optics partially compensate for each other’s aberrations and produce an improved retinal image. This result has a number of practical implications. For example, it shows the limitation of corneal topography as a guide for new refractive procedures and provides a strong endorsement of the value of ocular wave-front sensing for those applications.

15 September 2004 in Optics Letters
Verified
Journal Article
Closed access
PDF file
BHB. Hermann
B. Hermann
EFEnrique Josua Fernández
Enrique Josua Fernández
Angelika UnterhuberAngelika Unterhuber
Angelika Unterhuber
HSH. Sattmann
H. Sattmann
AFA. F. Fercher
A. F. Fercher
PAP. Artal
P. Artal
Merging of ultrahigh-resolution optical coherence tomography (UHR OCT) and adaptive optics (AO), resulting in high axial (3 µm) and improved transverse resolution (5–10 µm) is demonstrated for the first time to our knowledge in in vivo retinal imaging. A compact (300 mm×300 mm) closed-loop AO system, based on a real-time Hartmann–Shack wave-front sensor operating at 30 Hz and a 37-actuator membrane deformable mirror, is interfaced to an UHR OCT system, based on a commercial OCT instrument, employing a compact Ti:sapphire laser with 130-nm bandwidth. Closed-loop correction of both ocular and system aberrations results in a residual uncorrected wave-front rms of 0.1 µm for a 3.68-mm pupil diameter. When this level of correction is achieved, OCT images are obtained under a static mirror configuration. By use of AO, an improvement of the transverse resolution of two to three times, compared with UHR OCT systems used so far, is obtained. A significant signal-to-noise ratio improvement of up to 9 dB in corrected compared with uncorrected OCT tomograms is also achieved.

1 March 2001 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
HHHeidi Hofer
Heidi Hofer
PAPablo Artal
Pablo Artal
BSBen Singer
Ben Singer
JAJuan Luis Aragón
Juan Luis Aragón
DWDavid R. Williams
David R. Williams
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

1 June 2002 in Vision Research
Verified
Journal Article
Closed access
JCJosé Francisco Castejón-Mochón
José Francisco Castejón-Mochón
NLNorberto López-Gil
Norberto López-Gil
ABAntonio Benito
Antonio Benito
PAPablo Artal
Pablo Artal

1 August 2000 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
PPPedro M. Prieto
Pedro M. Prieto
FVFernando Vargas-Martı́n
Fernando Vargas-Martı́n
SGStefan Goelz
Stefan Goelz
PAPablo Artal
Pablo Artal
A description of a Hartmann–Shack sensor to measure the aberrations of the human eye is presented. We performed an analysis of the accuracy and limitations of the sensor using experimental results and computer simulations. We compared the ocular modulation transfer function obtained from simultaneously recorded double-pass and Hartmann–Shack images. The following factors affecting the sensor performance were evaluated: the statistical accuracy, the number of modes used to reconstruct the wave front, the size of the microlenses, and the exposure time.