Maria Angela Franceschini

Maria Angela Franceschini

Auto-generated profile, based on publicly available information

Maria Angela Franceschini

Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, USA

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2021 in Neurophotonics
Verified
Journal Article
Open access
PDF file
MYMeryem A. Yücel
Meryem A. Yücel
ALAlexander V. Lühmann
Alexander V. Lühmann
Felix ScholkmannFelix Scholkmann
Felix Scholkmann
JGJudit Gervain
Judit Gervain
IDIppeita Dan
Ippeita Dan
JBJames Bond
James Bond
Functional near-infrared spectroscopy (fNIRS) is a noninvasive, easy-to-use, and portable brain imaging technology that enables studies of normal brain function and alterations that arise in disease, both in the laboratory as well as in real-world settings.1 – 4 In 1977, Jöbsis used the technique for the first time to noninvasively assess changes in human brain oxygenation due to hyperventilation.5 Since then, the tool has evolved into an established noninvasive brain imaging modality and has been applied to a wide range of different populations and research questions.

1 January 2005 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
YZYiheng Zhang
Yiheng Zhang
DBDana H. Brooks
Dana H. Brooks
MFMaria Angela Franceschini
Maria Angela Franceschini
DBDavid A. Boas
David A. Boas
Diffuse optical imaging is an effective technique for noninvasive functional brain imaging. However, the measurements respond to systemic hemodynamic fluctuations caused by the cardiac cycle, respiration, and blood pressure, which may obscure or overwhelm the desired stimulus-evoked response. Previous work on this problem employed temporal filtering, estimation of systemic effects from background pixels, or modeling of interference signals with predefined basis functions, with some success. However, weak signals are still lost in the interference, and other complementary methods are desirable. We use the spatial behavior of measured baseline signals to identify the interference subspaces. We then project signals components in this subspace out of the stimulation data. In doing so, we assume that systemic interference components will be more global spatially, with higher energy, than the stimulus-evoked signals of interest. Thus, the eigenvectors corresponding to the largest eigenvalues of an appropriate correlation matrix form the basis for an interference subspace. By projecting the data onto the orthogonal nullspace of these eigenvectors, we can obtain more localized response, as reflected in improved contrast-to-noise ratio and correlation coefficient maps.

1 January 1995 in Optical Engineering
Verified
Journal Article
Open access
PDF file
SFSergio Fantini
Sergio Fantini
MFMaria-Angela Franceschini
Maria-Angela Franceschini
JMJohn S. Maier
John S. Maier
SWScott A. Walker
Scott A. Walker
BBBeniamino B. Barbieri
Beniamino B. Barbieri
EGEnrico Gratton
Enrico Gratton
We have designed a multisource frequency-domain spectrometer for the optical study of biological tissues. Eight multiplexed, intensity-modulated LEDs are employed as the light sources. Four of them emit light at a peak wavelength of 715 nm (λ1); the other four, 850 nm (λ2). The frequency of intensity modulation is 120 MHz. This instrument measures the frequency-domain parameters phase, dc intensity, and ac amplitude at the two wavelengths λ1 and λ2 and for different distances between light source and detector. From these frequency-domain raw data, the absolute values of the absorption and reduced scattering coefficients of tissue at λ1 and λ2 are obtained. The oxy- and deoxyhemoglobin concentrations, and hence the hemoglobin saturation, are then analytically derived from the molar extinction coefficients. Acquisition times as short as hundreds of milliseconds provide real-time monitoring of the measured parameters. We performed a systematic test in vitro to quantify the precision and accuracy of the instrument reading. We also report in vivo measurements. This spectrometer can be packaged as a compact portable unit.

20 June 2014 in Neurophotonics
Verified
Journal Article
Open access
PDF file
EBErin Buckley
Erin Buckley
APAshwin B. Parthasarathy
Ashwin B. Parthasarathy
PGP. Ellen Grant
P. Ellen Grant
AYArjun Yodh
Arjun Yodh
MFMaria Angela Franceschini
Maria Angela Franceschini
Diffuse correlation spectroscopy (DCS) is an emerging optical modality used to measure cortical cerebral blood flow. This outlook presents a brief overview of the technology, summarizing the advantages and limitations of the method, and describing its recent applications to animal, adult, and infant cohorts. At last, the paper highlights future applications where DCS may play a pivotal role individualizing patient management and enhancing our understanding of neurovascular coupling, activation, and brain development.

10 June 2003 in Psychophysiology
Verified
Journal Article
Closed access
PDF file
MFMaria Angela Franceschini
Maria Angela Franceschini
SFSergio Fantini
Sergio Fantini
JTJohn H. Thompson
John H. Thompson
JCJoseph P. Culver
Joseph P. Culver
DBDavid A. Boas
David A. Boas

1 January 2006 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MFMaria Angela Franceschini
Maria Angela Franceschini
DJDanny Kalathil Joseph
Danny Kalathil Joseph
THTheodore Huppert
Theodore Huppert
SDSolomon Diamond
Solomon Diamond
DBDavid A. Boas
David A. Boas
Functional optical brain imaging measurements require a fast image acquisition rate and coverage of a large area of the brain. A fast acquisition rate permits simple filtering of faster hemoglobin changes arising from, for example, cardiac pulsation from the relatively slow evoked hemodynamic response to brain activation. A spatial coverage not limited to the activation area but extended to areas not involved with the stimulation allows separation of evoked hemodynamic changes from global systemic oscillations of hemoglobin at similar frequencies, such as Mayer waves and respiration.1 With this purpose in mind, we have developed a fast multichannel optical imaging system with a large number of channels and a parallel acquisition scheme to allow a fast acquisition rate with a sufficiently high signal-to-noise ratio (SNR) to characterize brain activation and the background physiological fluctuations.