Representative Publications

View All Publications
2 November 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZCZhi Chen
Zhi Chen
XPXuejun Pei
Xuejun Pei
MYMin Yang
Min Yang
LPLi Peng
Li Peng
PSPuxin Shi
Puxin Shi
In an islanded inverter-interfaced microgrid, fault current is generally controlled at the same level of normal operation current due to limited capacities of inverters, rendering the conventional overcurrent protection methods impractical. To solve this issue, this paper presents a novel protection strategy, which incorporates flexible control of the inverter and setting of microprocessor-based relay (MBR). Once a short-circuit fault occurs at distribution line, a current limiting strategy combining with hysteresis control and maximum current RMS control (MCRC) is applied for the inverter to limit the fault current within permissible range. In the MCRC mode, a proportional fifth harmonic is injected to the fault current, facilitating the MBRs to identify the fault according to the harmonics components. Additionally, the fault current versus fault impedance droop control is synthesized to make the inverters output larger fault currents when the faults are closer to the inverters, and hence the MBRs can be coordinated with the inverse-time principle. The main advantages of this method are that it does not rely on high magnitude of the fault current to identify the fault, nor need communications among protective devices to ensure the coordination of protections. Experiments have been conducted to demonstrate the feasibility of this method.

6 January 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YXYangxiao Xiang
Yangxiao Xiang
XPXuejun Pei
Xuejun Pei
WZWu Zhou
Wu Zhou
YKYong Kang
Yong Kang
Hai WangHai Wang
Hai Wang
Currently, frequency-domain electromagnetic interference (EMI) modeling has become the most commonly used method for EMI prediction and filter design. However, because of the unpredictability of the ringing effect in the present frequency-domain EMI modeling methods, the precision of the predicted EMI interference source is notably limited, which results in the inaccuracy of the system level EMI prediction. In order to achieve an accurate EMI prediction, this study presents a systematical study on the interference source of a 10 kVA three-phase bridge converter. The precise mathematical models of the common-mode and differential-mode interference source are constructed. Then, the characteristics of the multiple ringing effect, which is an important part of the interference source, are intensively analyzed. Based on the investigation of interference source, an improved interference source synthesis method is proposed. It can quickly and precisely predict the CM and DM interference source with multiple ringing effect, which can be used to achieve accurate frequency domain EMI prediction. Moreover, the multiple ringing effect is extended for IGBT parasitic parameter measuring. Instead of complicated device-level measurement, the grounding capacitance and junction capacitance can be effectively extracted through the ringing frequency measurement.

20 May 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Hai WangHai Wang
Hai Wang
Huai WangHuai Wang
Huai Wang
ZWZhongxu Wang
Zhongxu Wang
YZYi Zhang
Yi Zhang
XPXuejun Pei
Xuejun Pei
YKYong Kang
Yong Kang
This letter proposes a method for the condition monitoring of submodule capacitors in modular multilevel converters (MMCs) without additional circuitry or computationally heavy algorithm. The proposed method leverages the discharging curve of submodule capacitors in connection with its parallel bleeding resistors. It is independent of the MMC control and modulation schemes. Moreover, it potentially does not require thermal and load related calibration for capacitor degradation monitoring. The principle, case study, and proof-of-concept of the proposed method are presented.

12 March 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZCZhi Chen
Zhi Chen
XPXuejun Pei
Xuejun Pei
MYMin Yang
Min Yang
LPLi Peng
Li Peng
In a low-voltage parallel inverter system, the active power, unbalanced power, and harmonic power generally cannot be properly shared among inverters with droop control due to the mismatch of output impedance. To address this issue, this paper proposes a two-stage adaptive virtual resistor (AVR) control scheme. In the first stage, a proportional-integral controller is applied to regulate the active power with the use of a synchronous maximum power bus (SMPB), and the reactive power is adjusted by means of a Q-ω droop controller. In the second stage, all inverters switch to a P-E droop control mode by introducing the AVRs at fundamental positive-sequence, negative-sequence, and harmonic frequencies. Not only can this method eliminate the active power, unbalanced power, and harmonic power-sharing errors, it can also reduce the voltage deviation caused by the droop control. Moreover, the synchronization between inverters can be guaranteed as long as the SMPB is present, without using voltage sensors at the point of common coupling. Simulation and experimental results are provided to verify the feasibility of this method.

24 August 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Hai WangHai Wang
Hai Wang
XPXuejun Pei
Xuejun Pei
YWYuhuan Wu
Yuhuan Wu
YXYangxiao Xiang
Yangxiao Xiang
YKYong Kang
Yong Kang
Series-parallel forward dc-dc converter system is a good option in high-voltage high-power applications. A switch fault, in this converter, should be detected as soon as possible, to avoid further damage and save maintenance cost. In this paper, a new switch fault diagnosis method, which treats output inductor voltages as diagnostic criteria, is proposed for this system. With the proposed method, expensive sensors are needless, since diagnostic signal can be easily acquired by adding a small auxiliary winding into inductor magnetic core. Based on the feature of diagnostic signals in such system, a low-cost diagnostic circuit is designed. The failed module caused by open circuit fault or short circuit fault could be detected within one switching period, allowing for an immediate fault-tolerant action. This method also shows generality for different connections and buck-type isolated topologies. Besides, it works reliably under input-voltage variation and load step, and no misdiagnosis will occur during normal dynamic process. Finally, experimental result verifies the effectiveness of this method. The proposed scheme has a good potential to be applied in real applications for its simplicity and robustness.

13 September 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YXYangxiao Xiang
Yangxiao Xiang
XPXuejun Pei
Xuejun Pei
MWMeijuan Wang
Meijuan Wang
PSPuxin Shi
Puxin Shi
YKYong Kang
Yong Kang
This paper presents an improved H8 power converter for common-mode voltage (CMV) reduction and electromagnetic interference suppression. The proposed H8 converter can realize zero CMV variation when entering and leaving the zero state, which is mainly achieved by both the improvement of the structure and the control strategy. For the system structure, two switches are added on the dc bus to float the ac part of the three-phase converter in the zero state. Besides, additional capacitors are used to realize controllable CMV. For the control strategy, a simple control strategy is proposed for the H8 converter. It can automatically adapt to the flowing orientation of the load current to realize synchronous switching of the power switches, which effectively eliminates the impact of the dead time. Through analysis, simulations, and experiment, a comparison between the proposed H8 converter and the conventional H6 converter is performed. Results validate the effectiveness of the H8 topology.