Zhi Chen

Zhi Chen

Auto-generated profile, based on publicly available information

Zhi Chen

State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Hubei, China

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZCZhi Chen
Zhi Chen
XPXuejun Pei
Xuejun Pei
MYMin Yang
Min Yang
LPLi Peng
Li Peng
PSPuxin Shi
Puxin Shi
In an islanded inverter-interfaced microgrid, fault current is generally controlled at the same level of normal operation current due to limited capacities of inverters, rendering the conventional overcurrent protection methods impractical. To solve this issue, this paper presents a novel protection strategy, which incorporates flexible control of the inverter and setting of microprocessor-based relay (MBR). Once a short-circuit fault occurs at distribution line, a current limiting strategy combining with hysteresis control and maximum current RMS control (MCRC) is applied for the inverter to limit the fault current within permissible range. In the MCRC mode, a proportional fifth harmonic is injected to the fault current, facilitating the MBRs to identify the fault according to the harmonics components. Additionally, the fault current versus fault impedance droop control is synthesized to make the inverters output larger fault currents when the faults are closer to the inverters, and hence the MBRs can be coordinated with the inverse-time principle. The main advantages of this method are that it does not rely on high magnitude of the fault current to identify the fault, nor need communications among protective devices to ensure the coordination of protections. Experiments have been conducted to demonstrate the feasibility of this method.

12 March 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZCZhi Chen
Zhi Chen
XPXuejun Pei
Xuejun Pei
MYMin Yang
Min Yang
LPLi Peng
Li Peng
In a low-voltage parallel inverter system, the active power, unbalanced power, and harmonic power generally cannot be properly shared among inverters with droop control due to the mismatch of output impedance. To address this issue, this paper proposes a two-stage adaptive virtual resistor (AVR) control scheme. In the first stage, a proportional-integral controller is applied to regulate the active power with the use of a synchronous maximum power bus (SMPB), and the reactive power is adjusted by means of a Q-ω droop controller. In the second stage, all inverters switch to a P-E droop control mode by introducing the AVRs at fundamental positive-sequence, negative-sequence, and harmonic frequencies. Not only can this method eliminate the active power, unbalanced power, and harmonic power-sharing errors, it can also reduce the voltage deviation caused by the droop control. Moreover, the synchronization between inverters can be guaranteed as long as the SMPB is present, without using voltage sensors at the point of common coupling. Simulation and experimental results are provided to verify the feasibility of this method.

1 September 2015
Verified
Conference Paper
Closed access
XPXuejun Pei
Xuejun Pei
ZCZhi Chen
Zhi Chen
SWShunchao Wang
Shunchao Wang
YKYong Kang
Yong Kang
Microgrids can provide various economic and environmental benefits but their implementation poses great technical challenges in control, protection and energy management. One of the most important technical aspects in microgrids is distribution system protection. This paper proposes an overcurrent protection strategy for microgrid consisting of only inverter-based distributed generation (IBDG) in islanded operation mode. On the basis of protecting semiconductor devices from damage once a short circuit fault occurs at the distribution line, a “short circuit impedance versus fault current (Z f -I f )” droop mechanism is introduced in the current-limiting controller to imitate the characteristic of power system short circuit current, which benefits the adoption of conventional overcurrent protection principle. Through using the microprocessor-based relay, a two-segment current protection algorithm is applied to guarantee the selectivity, rapidity and reliability of the protection system. The proposed protection method can provide a reference for the future microgrid protection. Experiments have been carried out to verify the feasibility of the proposed scheme.