2 November 2017 in IEEE Transactions on Power Electronics
In an islanded inverter-interfaced microgrid, fault current is generally controlled at the same level of normal operation current due to limited capacities of inverters, rendering the conventional overcurrent protection methods impractical. To solve this issue, this paper presents a novel protection strategy, which incorporates flexible control of the inverter and setting of microprocessor-based relay (MBR). Once a short-circuit fault occurs at distribution line, a current limiting strategy combining with hysteresis control and maximum current RMS control (MCRC) is applied for the inverter to limit the fault current within permissible range. In the MCRC mode, a proportional fifth harmonic is injected to the fault current, facilitating the MBRs to identify the fault according to the harmonics components. Additionally, the fault current versus fault impedance droop control is synthesized to make the inverters output larger fault currents when the faults are closer to the inverters, and hence the MBRs can be coordinated with the inverse-time principle. The main advantages of this method are that it does not rely on high magnitude of the fault current to identify the fault, nor need communications among protective devices to ensure the coordination of protections. Experiments have been conducted to demonstrate the feasibility of this method.
12 March 2018 in IEEE Transactions on Power Electronics
In a low-voltage parallel inverter system, the active power, unbalanced power, and harmonic power generally cannot be properly shared among inverters with droop control due to the mismatch of output impedance. To address this issue, this paper proposes a two-stage adaptive virtual resistor (AVR) control scheme. In the first stage, a proportional-integral controller is applied to regulate the active power with the use of a synchronous maximum power bus (SMPB), and the reactive power is adjusted by means of a Q-ω droop controller. In the second stage, all inverters switch to a P-E droop control mode by introducing the AVRs at fundamental positive-sequence, negative-sequence, and harmonic frequencies. Not only can this method eliminate the active power, unbalanced power, and harmonic power-sharing errors, it can also reduce the voltage deviation caused by the droop control. Moreover, the synchronization between inverters can be guaranteed as long as the SMPB is present, without using voltage sensors at the point of common coupling. Simulation and experimental results are provided to verify the feasibility of this method.