16 January 2013 in International Journal of Reproductive Medicine
Background. This paper presents the literature on biomarkers ofin vitrofertilisation (IVF) outcome, demonstrating the progression of these studies towards metabolite profiling, specifically metabolomics. The need for more, and improved, metabolomics studies in the field of assisted conception is discussed.Methods. Searches were performed on ISI Web of Knowledge SM for literature associated with biomarkers of oocyte and embryo quality, and biomarkers of IVF outcome in embryo culture medium, follicular fluid (FF), and blood plasma in female mammals.Results. Metabolomics in the field of female reproduction is still in its infancy. Metabolomics investigations of embryo culture medium for embryo selection have been the most common, but only within the last five years. Only in 2012 has the first metabolomics investigation of FF for biomarkers of oocyte quality been reported. The only metabolomics studies of human blood plasma in this context have been aimed at identifying women with polycystic ovary syndrome (PCOS).Conclusions. Metabolomics is becoming more established in the field of assisted conception, but the studies performed so far have been preliminary and not all potential applications have yet been explored. With further improved metabolomics studies, the possibility of identifying a method for predicting IVF outcome may become a reality.
20 September 2016 in The Analyst
To enable multiplexed protein analysis through the use of microarrays, reliable molecules capable of specifically binding to a protein of interest with high affinity are required. Further, this specificity and affinity must be retained upon immobilization to the microarray surface. This study investigates the performance of surface bound Affimer proteins, comparing the affinity and specificity of different binders for closely related immunoglobulin molecules using the quartz crystal microbalance with dissipation monitoring (QCM-D). It is demonstrated that the surface bound Affimer proteins are highly specific, differentiating between their target IgG and other closely related IgG subclasses. The binding affinities of the protein aptamers for their target IgG molecules are determined to be in the nanomolar range, comparable to typical antibody–antigen binding affinities. While measurements herein are done using QCM-D, the high specificity and binding affinities of the surface bound Affimer proteins opens applications in a range of microarray biosensors.
21 October 2012 in ISRN Vascular Medicine
SHShervanthi Homer-Vanniasinkam
Shervanthi Homer-Vanniasinkam
The anaerobic threshold (AT) measured by the cardiopulmonary exercise (CPX) test is becoming an established means of identifying patients at high risk of developing cardiac complications perioperatively. The aim of the present study was to investigate the relationship between AT and the plasma metabolic profile of patients undergoing aortic aneurysm repair surgery to see if an alternative or adjunct to the CPX test could be devised. Plasma was obtained from 15 male patients classified (through preoperative CPX tests) as having high (≥11.0 mL kg−1 min−1) or low (<11.0 mL kg−1 min−1) AT before and 1, 2, 24, 48, and 72 hours after elective open aortic aneurysm surgery. Samples were analysed using 1H-NMR spectroscopy coupled with multivariate statistical analysis. Principal components analysis (PCA) and partial least squares discriminant analysis (PLS-DA) distinguished between low- and high-AT patients postoperatively, with high AT patients being more tightly clustered. High AT patients had higher plasma lipid and lower 3-hydroxybutyrate and acetoacetate levels than low AT patients post-operatively. Similar differences were identified preoperatively. 1H-NMR metabolic profiling of plasma has identified molecules whose concentration correlates with AT scores. These may prove a useful biomarker in conjunction with AT in predicting response to major surgical procedures.