Daniela Gasperini

Daniela Gasperini

Auto-generated profile, based on publicly available information

Daniela Gasperini

Scuola Superiore Sant'Anna

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DGDaniela Gasperini
Daniela Gasperini
Filippo CostaFilippo Costa
Filippo Costa
GMGiuliano Manara
Giuliano Manara
Simone GenovesiSimone Genovesi
Simone Genovesi
Pressure sensors are employed in several industrial applications spanning from aerospace to healthcare, but they often require a wired connection between the sensing part and the reader and may result bulky or with a predefined footprint. In this work, a wireless pressure sensor realized with Additive Manufacturing (AM) is presented. The degrees of freedom offered by AM are exploited to design and quickly realize flexible substrates that are employed to transduce pressure into a shift in the frequency response of the sensor. In particular, two different polymers (PLA - Polylactic Acid and TPU - Thermoplastic Polyurethane) are investigated with different infill densities to manufacture the sensing component. The latter is wirelessly coupled with a low-profile reader represented by a high-impedance multiarm coplanar dipole. The sensor calibration curve is mapped by observing the reflection coefficient shift as a function of the variable applied pressure. Measurements assess the best performance for the PLA sensor with low infill density, which exhibits a good level of resolution.


13 May 2026 in Progress in Biomedical Engineering
Verified
Journal Article
Closed access
DGDaniela Gasperini
Daniela Gasperini
FPFrancesco Pierotti
Francesco Pierotti
LPLugi Privitera
Lugi Privitera
CSCatriona M Steele
Catriona M Steele
ABAndrea Bandini
Andrea Bandini
Neurological disorders, such as Parkinson's disease and stroke, often lead to neurogenic dysphagia, a swallowing disorder that compromises nutrition and increases the risk of malnutrition, aspiration of food, and even death. Although instrumental assessments remain the gold standard for evaluating swallowing function, their invasiveness, costs, and reliance on specialized clinical facilities limit their routine use. In this scoping review, we provide an overview of emerging noninvasive wearable devices for assessing and monitoring dysphagia in neurological disorders. We highlight the most widely used sensing technologies, such as accelerometers, microphones, and surface electromyography, alone and in multimodal configurations, discuss their respective strengths and limitations, and outline the main challenges and opportunities for advancing this field. Particular attention is given to the need for standardized protocols, robust clinical validation, and the integration of artificial intelligence to enable scalable and precise assessment. We conclude by discussing how these technologies can be applied in clinical practice to support earlier diagnosis, continuous monitoring, and improved management of swallowing function in individuals with neurological disorders.

21 October 2025 in IEEE Antennas and Propagation Magazine
Verified
Journal Article
Closed access
DGDaniela Gasperini
Daniela Gasperini
Filippo CostaFilippo Costa
Filippo Costa
LDLuca Daniel
Luca Daniel
GMGiuliano Manara
Giuliano Manara
Simone GenovesiSimone Genovesi
Simone Genovesi
Electromagnetic (EM) fields are widely used in several applications where maximizing penetration into the target object is desirable, such as biomedical imaging and sensing. This improvement is often achieved through a matching layer (ML), which can be either a dielectric material or dielectrics patterned with metallic structures. A metasurface ML (MML) represents an improvement over traditional dielectric MLs (DMLs) since it provides better impedance matching, leading to increased field strength within the target and reduced ML thickness. However, designing a MML for near-field EM sources has traditionally relied on time-consuming full-wave simulations. This article introduces a novel analytical approach to designing an MML for arbitrary near-field EM sources, providing a more efficient and effective solution. Three cases are analyzed to assess the reliability of the proposed approach: a short dipole, a small loop, and a patch antenna. The performance of the MML, obtained by an analytical procedure, is preliminarily assessed with full-wave simulations and then experimentally validated. The optimized MML is fabricated using 3D and 2D additive manufacturing (AM) techniques. A comparative analysis across all the considered scenarios confirms the robustness and reliability of the proposed MML design strategy.