12 January 2024 in IEEE Access
The development of wireless systems technologies consists, on the one hand, in new methods of generating a radio signal and, on the other hand, in optimizing the transmission of this signal, for instance, by using modern multiantenna technology. This is particularly visible in cellular systems, especially 5G, where network capacity, link throughput and energy optimization are very important. Changes in technology are followed by the need to adapt methods for measuring the electromagnetic field strength in the vicinity of the base station to new cellular standards, mainly because of the introduction of features that allow for real time change in radiation pattern and power distribution. This paper presents basics of multiantenna systems and beamforming techniques for modern cellular networks and the related consequences of evaluating electromagnetic field distribution in the vicinity of such installations for the purpose of compliance with the applicable radio frequency exposure limits. Measurement methods are presented together with the proposal for the optimized and simplified methodology, which can be used for the in-situ electromagnetic field exposure assessment in the vicinity of base stations with multiantenna systems and the configured maximum transmitted power. The measurement methodology has been verified empirically.
17 December 2025 in IEEE Transactions on Instrumentation and Measurement
The electromagnetic field (EMF) measurements, in the bioelectromagnetics, are usually performed in the near-field. It is shown that the near-field conditions may be expected everywhere. It confirms the authors’ suggestion: the near-field may be expected, whenever we perform measurements. Factors limiting the measurement accuracy are discussed. The first of them is a low class of the EMF standards applied for the meter calibration. A block diagram of a typical meter is presented and the significance of the separate blocks in the accuracy budget is discussed. The measurement accuracy may be limited by the susceptibility of those blocks to the EMF. Problems with the experience of measuring person (-s) are mentioned. An accuracy budget is estimated, indicating an uncertainty (RMSE) of about ±17%, while monochromatic field intensity is measured. A possibility of errors at the level of one order of magnitude may be expected while complex-spatial-time-frequency-spectral-alternated fields are measured. Unlike other studies, this work provides six reproducible test protocols and l to directly evaluate EMF meters used in bioelectromagnetics by verifying the technical data of applied meters and probes as declared by their manufacturers. Errors in biomedical investigations and their role in shaping protection standards are discussed. The standards should be matched to metrological possibilities, regardless of protected field levels. A close cooperation between biomedical investigators and their technical assistance during experiments is suggested.