23 September 2014 in Analytical Chemistry
Demand for highly sensitive, robust diagnostics and environmental monitoring methods has led to extensive research in improving reporter technologies. Inorganic phosphorescent materials exhibiting persistent luminescence are commonly found in electroluminescent displays and glowing paints but are not widely used as reporters in diagnostic assays. Persistent luminescence nanoparticles (PLNPs) offer advantages over conventional photoluminescent probes, including the potential for enhanced sensitivity by collecting time-resolved measurements or images with decreased background autofluorescence while eliminating the need for expensive optical hardware, superior resistance to photobleaching, amenability to quantitation, and facile bioconjugation schemes. We isolated rare-earth doped strontium aluminate PLNPs from larger-particle commercial materials by wet milling and differential sedimentation and water-stabilized the particles by silica encapsulation using a modified Stöber process. Surface treatment with aldehyde silane followed by reductive amination with heterobifunctional amine-poly(ethylene glycol)-carboxyl allowed covalent attachment of proteins to the particles using standard carbodiimide chemistry. NeutrAvidin PLNPs were used in lateral flow assays (LFAs) with biotinylated lysozyme as a model analyte in buffer and monoclonal anti-lysozyme HyHEL-5 antibodies at the test line. Preliminary experiments revealed a limit of detection below 100 pg/mL using the NeutrAvidin PLNPs, which was approximately an order of magnitude more sensitive than colloidal gold.
3 February 2017 in Lab on a Chip
Through their computational power and connectivity, smartphones are poised to rapidly expand telemedicine and transform healthcare by enabling better personal health monitoring and rapid diagnostics. Recently, a variety of platforms have been developed to enable smartphone-based point-of-care testing using imaging-based readout with the smartphone camera as the detector. Fluorescent reporters have been shown to improve the sensitivity of assays over colorimetric labels, but fluorescence readout necessitates incorporating optical hardware into the detection system, adding to the cost and complexity of the device. Here we present a simple, low-cost smartphone-based detection platform for highly sensitive luminescence imaging readout of point-of-care tests run with persistent luminescent phosphors as reporters. The extremely bright and long-lived emission of persistent phosphors allows sensitive analyte detection with a smartphone by a facile time-gated imaging strategy. Phosphors are first briefly excited with the phone's camera flash, followed by switching off the flash, and subsequent imaging of phosphor luminescence with the camera. Using this approach, we demonstrate detection of human chorionic gonadotropin using a lateral flow assay and the smartphone platform with strontium aluminate nanoparticles as reporters, giving a detection limit of ≈45 pg mL−1 (1.2 pM) in buffer. Time-gated imaging on a smartphone can be readily adapted for sensitive and potentially quantitative testing using other point-of-care formats, and is workable with a variety of persistent luminescent materials.
29 September 2008 in Biopolymers
24 March 2022 in ACS Nano
1 August 1999 in Nature Biotechnology