Brian Murphy

Brian Murphy

Auto-generated profile, based on publicly available information

Brian Murphy

Cumulus Neuroscience, Dublin Ireland

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2018 in Journal of Neural Engineering
Verified
Journal Article
Closed access
DYD Young
D Young
FWF Willett
F Willett
WMW D Memberg
W D Memberg
BMB Murphy
B Murphy
BWBenjamin L Walter
Benjamin L Walter
AAA B Ajiboye
A B Ajiboye
Objective . Functional electrical stimulation (FES) is a promising technology for restoring movement to paralyzed limbs. Intracortical brain–computer interfaces (iBCIs) have enabled intuitive control over virtual and robotic movements, and more recently over upper extremity FES neuroprostheses. However, electrical stimulation of muscles creates artifacts in intracortical microelectrode recordings that could degrade iBCI performance. Here, we investigate methods for reducing the cortically recorded artifacts that result from peripheral electrical stimulation. Approach . One participant in the BrainGate2 pilot clinical trial had two intracortical microelectrode arrays placed in the motor cortex, and thirty-six stimulating intramuscular electrodes placed in the muscles of the contralateral limb. We characterized intracortically recorded electrical artifacts during both intramuscular and surface stimulation. We compared the performance of three artifact reduction methods: blanking, common average reference (CAR) and linear regression reference (LRR), which creates channel-specific reference signals, composed of weighted sums of other channels. Main results . Electrical artifacts resulting from surface stimulation were 175 × larger than baseline neural recordings (which were 110 µ V peak-to-peak), while intramuscular stimulation artifacts were only 4 × larger. The artifact waveforms were highly consistent across electrodes within each array. Application of LRR reduced artifact magnitudes to less than 10 µ V and largely preserved the original neural feature values used for decoding. Unmitigated stimulation artifacts decreased iBCI decoding performance, but performance was almost completely recovered using LRR, which outperformed CAR and blanking and extracted useful neural information during stimulation artifact periods. Significance . The LRR method was effective at reducing electrical artifacts resulting from both intramuscular and surface FES, and almost completely restored iBCI decoding performance (>90% recovery for surface stimulation and full recovery for intramuscular stimulation). The results demonstrate that FES-induced artifacts can be easily mitigated in FES + iBCI systems by using LRR for artifact reduction, and suggest that the LRR method may also be useful in other noise reduction applications.

29 January 2019 in Journal of Neural Engineering
Verified
Journal Article
Closed access
DYD Young
D Young
FWF Willett
F Willett
WMW D Memberg
W D Memberg
BMB Murphy
B Murphy
PRP Rezaii
P Rezaii
AAA B Ajiboye
A B Ajiboye
Objective . Brain–computer interfaces (BCIs) are a promising technology for the restoration of function to people with paralysis, especially for controlling coordinated reaching. Typical BCI studies decode Cartesian endpoint velocities as commands, but human arm movements might be better controlled in a joint-based coordinate frame, which may match underlying movement encoding in the motor cortex. A better understanding of BCI controlled reaching by people with paralysis may lead to performance improvements in brain-controlled assistive devices. Approach . Two intracortical BCI participants in the BrainGate2 pilot clinical trial performed a visual 3D endpoint virtual reality reaching task using two decoders: Cartesian and joint velocity. Task performance metrics (i.e. success rate and path efficiency) and single feature and population tuning were compared across the two decoder conditions. The participants also demonstrated the first BCI control of a fourth dimension of reaching, the arm’s swivel angle, in a 4D posture matching task. Main results . Both users achieved significantly higher success rates using Cartesian velocity control, and joint controlled trajectories were more variable and significantly more curved. Neural tuning analyses showed that most single feature activity was best described by a Cartesian kinematic encoding model, and population analyses revealed only slight differences in aggregate activity between the decoder conditions. Simulations of a BCI user reproduced trajectory features seen during closed-loop joint control when assuming only Cartesian-tuned features passed through a joint decoder. With minimal training, both participants controlled the virtual arm’s swivel angle to complete a 4D posture matching task, and achieved significantly higher success using a Cartesian + swivel velocity decoder compared to a joint velocity decoder. Significance . These results suggest that Cartesian velocity command interfaces may provide better BCI control of arm movements than other kinematic variables, even in 4D posture tasks with swivel angle targets.

14 December 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
FWFrancis R. Willett
Francis R. Willett
BMBrian A. Murphy
Brian A. Murphy
DYDaniel R. Young
Daniel R. Young
WMWilliam D. Memberg
William D. Memberg
CBChristine H. Blabe
Christine H. Blabe
AAAbidemi Bolu Ajiboye
Abidemi Bolu Ajiboye
Objective: Recent reports indicate that making better assumptions about the user’s intended movement can improve decoder calibration for intracortical brain-computer interfaces. Several methods now exist for estimating user intent, including an optimal feedback control model, a piecewise-linear feedback control model, ReFIT, and other heuristics. Which of these methods yields the best decoding performance? Methods: Using data from the BrainGate2 pilot clinical trial, we measured how a steady-state velocity Kalman filter decoder was affected by the choice of intention estimation method. We examined three separate components of the Kalman filter: dimensionality reduction, temporal smoothing, and output gain (speed scaling). Results: The decoder’s dimensionality reduction properties were largely unaffected by the intention estimation method (the unsmoothed velocity vectors differed by 50% difference in average values). Surprisingly, simulation results show that these differences in gain and smoothing values were largely arbitrary, as all methods failed to optimize the gain and smoothing values to match the task parameters. Conclusion: Our results show that, gain and smoothing differences aside, current intention estimation methods yield nearly equivalent decoders and that simple models of user intent, such as a position error vector (target position minus cursor position), perform comparably to more elaborate models. Our results also highlight that current calibration methods yield arbitrary differences in gain and smoothing properties that can confound decoder comparisons.

1 June 2013 in Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Open access
ZPZachary S Peacock
Zachary S Peacock
BTBrad J. Tricomi
Brad J. Tricomi
BMBrian A. Murphy
Brian A. Murphy
JMJohn C. Magill
John C. Magill
LKLeonard B. Kaban
Leonard B. Kaban
Maria J. TroulisMaria J. Troulis
Maria J. Troulis
To determine if automated continuous distraction osteogenesis (DO) at rates faster than 1 mm/day results in bone formation by clinical and radiographic criteria, in a minipig model. An automated, continuous, curvilinear distraction device was placed across a mandibular osteotomy in 10 minipigs. After 12 mm of distraction and 24 days of fixation, the animals were sacrificed and bone healing was evaluated. The continuous distraction rates were 1.5 mm/day (n = 5) and 3 mm/day (n = 5). A semiquantitative scale was used to assess the ex vivo clinical appearance of the distraction gap (3 = osteotomy not visible; 2 = 50% visible; 0 = 100% visible), stability (3 = no mobility; 2 and 1 = mobility in 1 plane or 2 planes, respectively; 0 = mobility in 3 planes), and radiographic density (4 = 100% of gap opaque; 3 = >75%; 2 = 50% to 75%; 1 = <50%; 0 = radiolucent). Groups of 4 minipigs distracted discontinuously at 1, 2, and 4 mm/day served as controls. Automated, continuous DO at 1.5-mm/day and 3-mm/day had similar bone formation compared to discontinuous DO at 1-mm/day. The continuous DO 1.5-mm/day group had significantly higher scores for appearance and radiographic density compared with the discontinuous 4-mm/day group. The continuous DO 3-mm/day group had significantly higher scores for appearance and radiographic density compared with the discontinuous 4-mm/day group and greater stability compared with the discontinuous 2- and 4-mm/day groups. Results of this preliminary study indicate that continuous DO at rates of 1.5 and 3.0 mm/day produces better bone formation compared with discontinuous DO at rates faster than 1 mm/day.

1 July 2017 in Cortex
Verified
Journal Article
Closed access
YYYing Yang
Ying Yang
MDMichael Walsh Dickey
Michael Walsh Dickey
JFJulie Fiez
Julie Fiez
BMBrian Murphy
Brian Murphy
TMTom Mitchell
Tom Mitchell
WWWei Wang
Wei Wang

25 December 2023 in Alzheimer's & Dementia
Verified
Journal Article
Open access
LRLaura M Rueda‐Delgado
Laura M Rueda‐Delgado
ABAlison R Buick
Alison R Buick
OHOrla Hardiman
Orla Hardiman
KMKinan Muhammed
Kinan Muhammed
HNHugh Nolan
Hugh Nolan
BMBrian Murphy
Brian Murphy
Background: Clinic‐based biomarkers are effective in tracking disease progression in clinical research, but do not scale to support public health needs or large‐scale real‐world studies. Purely digital markers are scalable but lack the objectivity and neurobiological grounding of clinical measures. These first results of a real‐world feasibility study demonstrate that objective measures of a range of domains including EEG (Figure 1) are user‐friendly and suitable for repeated at‐home use by patients and older controls.Method: 60 patients and 60 matched controls are being recruited for a 1‐year repeated sampling study in the UK. Patients were clinically assessed to have mild Alzheimer’s type dementia. Participants were asked to complete about 30 minutes of behavioral tasks including memory, executive function, affective processing and language, while synchronized EEG was recorded using a self‐applied dry‐sensor headset. This interim data is from an initial 2‐week burst sampling period, for the first half of the cohorts.Result: Adherence was 76% for the dementia group (N = 29, mean age = 75; ADAS = Cog 24.3) and 88% for the control group (N = 36, mean age = 71; ADAS = Cog 7.8). A symbol substitution task (executive function) differentiated strongly between groups (t(53) = 6.9), and correlated highly with a conventional pen‐and‐paper DSST benchmark (rho = 0.79). An associative memory task also patterned strongly with disease status (t(54) = 5.7) and correlated with the Verbal Paired Associates benchmark (rho = 0.76). The grand average P300 ERP, elicited by a gamified 2‐stimulus oddball task, showed characteristic features of sensory and higher cognitive processing (Figure 2). As expected in the patient group, the P300 was reduced and delayed; and the resting‐state EEG theta and alpha power were enhanced and reduced, respectively. Radar plots (Figure 3), illustrate the pattern observed across domains in one representative Alzheimer’s patient and one control. Data from a fronto‐temporal dementia sister study is included for comparison.Conclusion: Interim data from this first‐in‐class study suggest that patients with mild Alzheimer’s disease dementia are capable and willing to participate in intensive home‐based functional neurophysiology studies, if technology is designed to be engaging and easy to use. Initial examination of the data aligns with established benchmarks, constituting positive early evidence for construct validity and technical feasibility.