Yuewu Wang

Yuewu Wang

Auto-generated profile, based on publicly available information

Yuewu Wang

School of Automation, Guangxi University of Science and Technology, Liuzhou, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2017 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Zhuoli ZhaoZhuoli Zhao
Zhuoli Zhao
PYPing Yang
Ping Yang
YWYuewu Wang
Yuewu Wang
ZXZhirong Xu
Zhirong Xu
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
As the penetration of PV generation increases, there is a growing operational demand on PV systems to participate in microgrid frequency regulation. It is expected that future distribution systems will consist of multiple microgrid clusters. However, interconnecting PV microgrids may lead to system interactions and instability. To date, no research work has been done to analyze the dynamic behavior and enhance the stability of microgrid clusters considering the dynamics of the PV primary sources and dc links. To fill this gap, this paper presents comprehensive modeling, analysis, and stabilization of PV-based multiple microgrid clusters. A detailed small-signal model for PV-based microgrid clusters considering local adaptive dynamic droop control mechanism of the voltage-source PV system is developed. The complete dynamic model is then used to access and compare the dynamic characteristics of the single microgrid and interconnected microgrids. In order to enhance system stability of the PV microgrid clusters, a tie-line flow and stabilization strategy is proposed to suppress the introduced interarea and local oscillations. Robustly selecting of the key control parameters is transformed to a multiobjective optimization problem which is solved by genetic algorithm (GA). The proposed damping controller can effectively damp the power oscillations and provide robust control performance under variable operating conditions. Theoretical analysis, simulation results under various scenarios are presented to verify the effectiveness of the proposed scheme.

29 December 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Zhuoli ZhaoZhuoli Zhao
Zhuoli Zhao
MZMingyu Zhang
Mingyu Zhang
ZZZehan Zhang
Zehan Zhang
YWYuewu Wang
Yuewu Wang
RCRunting Cheng
Runting Cheng
Loi Lei LaiLoi Lei Lai
Loi Lei Lai
This article proposes a novel maximum power point tracking (MPPT) method based on the variant of the pigeon-inspired optimization (PIO) algorithm for photovoltaic systems under partial shading conditions (PSCs). The proposed method integrates the hierarchical network behavior of pigeon flock and revises the map and compass operator of the original PIO algorithm to improve optimization efficiency. In addition, the landmark operator is used to perform a small-scale search to achieve fast tracking. Based on the combination of these mechanisms and dual-mode dynamic tracking scheme, the proposed hierarchical pigeon-inspired optimization (HPIO) MPPT method has a powerful search ability to deal with PSCs. To verify the superiority of the proposed HPIO MPPT method, it is compared with other existing advanced MPPT methods in simulation and experiments. Compared with traditional MPPT techniques based on artificial intelligence, the proposed HPIO MPPT method has a higher success rate in tracking GMPP and excellent tracking speed under PSCs. And the HPIO method also shows excellent performance under complex PSC with multiple clusters and load-variation conditions.

24 May 2024 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Zhuoli ZhaoZhuoli Zhao
Zhuoli Zhao
ZZZehan Zhang
Zehan Zhang
YWYuewu Wang
Yuewu Wang
CLChang Liu
Chang Liu
CPChangsong Peng
Changsong Peng
Loi Lei LaiLoi Lei Lai
Loi Lei Lai
Driven by carbon neutrality and sustainable development policies, the adoption of photovoltaic (PV) sources has grown significantly in recent years. The integration of distributed PV generation into DC microgrids has proven to be an effective solution. However, as the penetration of the PV sources increases, there is a growing need for these sources to participate in DC bus voltage regulation. To address this issue, this paper proposes a decentralized control strategy for PV-based DC microgrids that enables cooperation among multiple sources in the microgrid without communication. The innovative FCS-MPC control strategy is proposed for grid-forming PV units, taking into account the characteristics of PV and eliminating the requirement for an external PI controller. This strategy facilitates cooperation with grid-forming battery energy storage (BES) units based on FCS-MPC, leading to improved stability, reliability, and economy of the microgrid. Furthermore, various operating conditions such as islanded operation, grid-connected operation, switching between grid-connected and islanded modes, and bus short circuits are fully considered in the proposed strategy. Hardware-in-the-loop experiments are conducted to compare the performance of the proposed strategy against the existing strategies. The results demonstrate the effectiveness of the proposed strategy.

1 October 2014
Verified
Conference Paper
Closed access
YWYuewu Wang
Yuewu Wang
PYPing Yang
Ping Yang
XYXu Yin
Xu Yin
YMYiwei Ma
Yiwei Ma
Low-voltage ride-through (LVRT) requirements demand inverter-interfaced renewable energy power generation systems to remain connected in the presence of grid faults, by injecting required reactive current for voltage support. In this paper, a two-stage grid-connected photovoltaic inverter consists of a boost converter and a three-level T-type inverter is investigated. A stable decoupled double synchronous reference frame phase-locked loop (DDSRF-PLL) is adopted appropriately for three-phase grid synchronization under faulty grids or abnormal conditions. Moreover, the DDSRF could extract and separate both positive- (PS) and negative-sequence (NS) components of grid voltage and current. During normal operation, the cascaded control structure of T-type inverter is composed of an outer proportional-integral-derivative (PID) dc-link voltage control loop and four inner multivariable-PI current control loops. Once grid voltage sags are detected by the separated d-axis PS voltage component, the current references are calculated according to the sag depth so as to stay in maximum power point tracking (MPPT) mode or switch to Non-MPPT mode, meeting the latest LVRT requirements of China. The performance of the LVRT capability is evaluated by simulation and experimental results.

31 December 2024 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Zhuoli ZhaoZhuoli Zhao
Zhuoli Zhao
QYQinggang Yang
Qinggang Yang
ZZZehan Zhang
Zehan Zhang
YWYuewu Wang
Yuewu Wang
HTHanyuan Tan
Hanyuan Tan
Loi Lei LaiLoi Lei Lai
Loi Lei Lai
The transition from traditional power systems to smart grids has led to the widespread utilization of multi-microgrids (MMGs) as a medium for integrating renewable energy sources (RES). However, due to the weak damping and low inertia characteristics of interconnected systems, multi-scale oscillation problems inevitably arise during autonomous operation. In order to explore these undesirable oscillation characteristics and achieve effective suppression. Firstly, this paper establishes a wind-solar hybrid MMGs model considering the characteristics of primary energy side and uncertain disturbances, and further reveals the correlation between system states and dominant oscillatory modes through eigenvalue analysis. Meanwhile, modal controllability and observability quantification analysis are employed to optimize the selection of measurement and control signals for the stabilization controller. Secondly, a hierarchical distributed model predictive stabilization control (HDMPSC) strategy with two-level oscillation control loops is innovatively proposed, where lower-level controllers are designed to address local modes and upper-level controllers work collaboratively to effectively mitigate poorly damped inter-area modes. Besides, the operational constraints are included in all stabilization controllers, providing a more feasible and reliable solution space. Finally, time-domain simulation and hardware-in-the-loop (HIL) experimental results verify the effectiveness of the proposed control scheme.

20 July 2016 in Journal of Power Electronics
Verified
Journal Article
Closed access
YWYuewu Wang
Yuewu Wang
PYPing Yang
Ping Yang
ZXZhirong Xu
Zhirong Xu