Chanmin Su

Chanmin Su

Auto-generated profile, based on publicly available information

Chanmin Su

State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2023 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
ZZZhongyuan Zhu
Zhongyuan Zhu
HTHui Tang
Hui Tang
YHYunwei Huang
Yunwei Huang
ZLZhihang Lin
Zhihang Lin
YTYanling Tian
Yanling Tian
CSChanmin Su
Chanmin Su
Micro/mini light-emitting diodes (LEDs) display panel inspection and repairs have a high demand for vibration isolating devices to protect industrial-level atomic force microscopes (AFM scanning head) against vibrations. The motivation of this work is to combine the advantages of both passive and active vibration isolation strategies to improve inspection performance. The developed self-stabilization device achieves this objective with a design that incorporates a suspension-type passive vibration isolation unit and integrates it with the modified active–passive hybrid (MAPH) vibration isolation strategy using piezoelectric ceramics (PZT) and voice coil motors (VCM) as compensators. First, the design, modeling, and optimization of a self-stabilization device are presented based on the MAPH vibration isolation strategy. To satisfy the requirements of vibration isolation performance and a lightweight design, a multiobjective optimization task was conducted. Next, a tailor-made double compensating PID controller was designed to allow this mechanism to run in the MAPH method to effectively isolate vibrations. Finally, a series of validation experiments, including passive vibration isolation performance tests and MAPH closed-loop tests, were applied. From 1 to 500 Hz, more than 98% frequency domain achieved a vibration isolation rate of 90%, the vibration amplification effect of the passive vibration isolation was significantly suppressed, the steady-state positioning accuracy reached $\pm 0.1\;\mu$ m, load capacity was up to 2.5 kg, the attenuation ratio of the disturbances reached up to 70%, and the heat of the VCM was effectively reduced. All results comprehensively confirmed that the developed compliant MAPH vibration isolation system has achieved a satisfactory self-stabilization function.

28 November 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HSHuiyao Shi
Huiyao Shi
JSJialin Shi
Jialin Shi
YYYang Yang
Yang Yang
STSi Tang
Si Tang
CSChanmin Su
Chanmin Su
Lianqing LiuLianqing Liu
Lianqing Liu
The scanning laser Doppler vibrometer (SLDV) is an extremely valuable method for studying the dynamic properties of vibrating objects, such as those in industrial production, entomology research, and biomedical testing. The traditional SLDV method scans samples using an inclined laser, which ignores the three-dimensional (3D) information of the sample, resulting in a relatively complicated calculation process. In industrial processes and scientific research, the measured target may have a known 3D regular surface. When a structure with height information moves laterally, it causes a change in longitudinal information, which is of great benefit in the analysis of the 3D vibration and displacement information of the target. In this paper, continuous and interval scanning laser Doppler methods are proposed to expand the measuring capability of SLDV methods, based on the scanning on spherical structures. First, a spherical structure is introduced to simplify the solution to spiral vibrations. The high-precision displacement can also be calculated by fitting the circular scanning curve. Finally, the scanning method for 3D displacement measurement is experimentally validated, and the theoretical errors are demonstrated. This work provides a new methodology to realize both periodic and nonperiodic displacements in all degrees of freedom with high accuracy using a single-point SLDV, which is expected to have a long-term impact on industry vibration analysis and biological motion research. Most importantly, setting a reflector with a spherical surface on the end effector of the micro-nano robot can realize the 3D cross-scale repeated localization.

13 September 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SZShenghang Zhai
Shenghang Zhai
JSJialin Shi
Jialin Shi
PYPeng Yu
Peng Yu
TYTie Yang
Tie Yang
YYYang Yang
Yang Yang
Lianqing LiuLianqing Liu
Lianqing Liu
Displacement sensors with subnanometer resolution and wide bandwidth are essential for micro-nano manufacturing, measurement, and motion control systems. However, the current displacement sensing methods have various limitations, such as requirements for the optical or electrical properties of the target sample, the need to be in contact with the sample surface, and the contradiction between the accuracy and bandwidth. This study proposes a displacement sensing method with wide bandwidth and subnanometer resolution, which is not only insensitive to the material properties of the measured sample but is not in contact with the sample. The squeeze film damping (SFD) force exerted on the resonant micro-cantilever plate is sensitive to the plate-sample displacement (film height), which can be converted into the cantilever vibration amplitude. The resulting amplitude variations can be measured by the optical lever method. Herein, the mathematical model of the resonant cantilever and SFD force is established. The effects of driving amplitude and frequency on displacement sensing are studied. Evidently, increasing the driving amplitude and using a resonant driving frequency can improve sensing sensitivity and resolution. Experiments reveal that the proposed method is insensitive to sample material changes, has a resolution of 0.21 nm (STD), range of 5 μm, bandwidth of about 515 Hz, and can be utilized in gantry vibration measurement.

21 October 2024 in IEEE Electron Device Letters
Verified
Journal Article
Closed access
JWJinzhe Wu
Jinzhe Wu
JSJialin Shi
Jialin Shi
ZLZhaoxi Li
Zhaoxi Li
PYPeng Yu
Peng Yu
HSHuiyao Shi
Huiyao Shi
Lianqing LiuLianqing Liu
Lianqing Liu
Acoustically actuated microrobots have attracted considerable attention, which have developed various geometries. These microrobots are powered through their interaction with acoustics. The use of ultrahigh-frequency (UHF) ultrasound yields a focus on the order of several microns, thus actuating microrobots with accurate, strong, and two-directional forces. However, to date no technique can simultaneously calibrate the actual axial and lateral radiation forces of UHF ultrasound above 60 MHz acting on a microrobot with arbitrary geometry. To address this issue, we present a force sensor based on a micropipette. The force sensor consists of the micropipette, microrobot with a marker, and fixed base, which calibrates the overall spring constants. By combining the two-directional displacements actuated by the axial and lateral radiation forces, we calibrated the forces with a resolution of hundreds of piconewtons. We calibrated the axial and lateral radiation forces on cylindrical and spherical microrobots with the same volume and further investigated the influences of the duty factor and excitation voltage. This method complements a crucial design link in UHF ultrasound actuating microrobots.

9 December 2024 in IEEE Transactions on Nanotechnology
Verified
Journal Article
Closed access
HSHuiyao Shi
Huiyao Shi
STSi Tang
Si Tang
JSJialin Shi
Jialin Shi
PYPeng Yu
Peng Yu
TYTie Yang
Tie Yang
Lianqing LiuLianqing Liu
Lianqing Liu
Force curve is the most important techniques for accurate measuring the stiffness, adhesion and energy dissipation. However, due to the challenges of probe-cell localization, this type of single-cell analysis tool has become a labor-intensive and time-consuming procedure. Here, we demonstrate an automatic positioning methods based on micropipette for force curves acquisition. The automation covers the detection of cells in label-free images, pre-positioning and automatic focusing of micropipette, as well as automated force curves. This new method discards silicon-based probes used in traditional AFM, and instead utilizing a transparent micropipette with an unobstructed tip as the sensor. This advancement enables accurate localization of the probe tip and cell under an optical microscope. Furthermore, during the probe positioning process, we have implemented a pre-localization method using focused laser projection. This allows for manual adjustment of the probe tip within a range of 70 micrometers, providing precise region of interests (ROI) for automatic tip focusing. Combining with the aforementioned techniques. We also demonstrate the high-precision localization and force curve acquisition of eight fixed cells on a single image. The measurement results indicate that the positioning error will not exceed 3.4 μm. Our work has effectively enhanced the efficiency of cellular mechanical measurements and holds the potential to achieve automated high-throughput single-cell analysis and drug screening.

2 September 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SZShenghang Zhai
Shenghang Zhai
LLLiang Liang
Liang Liang
JSJialin Shi
Jialin Shi
PYPeng Yu
Peng Yu
TYTie Yang
Tie Yang
Lianqing LiuLianqing Liu
Lianqing Liu
Large industrial atomic force microscopy (AFM) plays a pivotal role in the metrology of large samples. However, significant vibrations between the large AFM and the sample can limit the resolution of the AFM. By detecting and subtracting these vibrations from the image signal, image noise can be effectively reduced. However, measuring these vibrations presents a challenge, particularly because most large samples are dielectric and fragile, which makes conventional electrical vibration sensors unsuitable. Furthermore, the frequency responses of the vibration sensor and the AFM differ. Therefore, directly subtracting the vibration signal from the AFM’s topography signal can lead to considerable errors owing to the magnitude and phase differences between these signals. In our study, we designed a non-contact vibration sensor leveraging the squeeze-film-damping-effect. This sensor can measure dielectric samples and achieve a high resolution (better than 0.1 nm). We processed the measured vibration signal using a magnitude-phase adjuster to compensate for the dynamic differences between the sensor and the AFM. We managed to limit the subtraction error to within 1 nm using this adjuster, achieving a reduction of 63-88% in subtraction errors. Additionally, we validated our vibration reduction method using topography images of standard grating samples.