8 December 2022 in IEEE Transactions on Automation Science and Engineering
Assist-as-needed (AAN) assistance can promote active voluntary participation in rehabilitation and motor function recovery of post-stroke patients. However, different patients have personalized damaged regions and recovery states, causing difficulties to obtain adaptive and customized assistance in robot-assisted rehabilitation. This paper presents a mirror Adaptive Assist-As-Needed (AAAN) scheme, including two modules of Multi-Sensors Fused Estimation (MSFE) and Online Incremental Mirror Adaptation (OIMA) , to encourage the subjects to actively participate in rehabilitation. Specifically, the first MSFE module can obtain the needed assistance based on the functional capability of the post-stroke patients via the data fusion of biological and motional signals using Kalman Filter. The second OIMA module fine-tunes the control torques estimated by MSFE to adapt the muscle fatigue and stiffness varieties of the affected limb based on the motion and physiological reference of the mirror healthy limb. The results demonstrate that the AAAN strategy can realize the transparent mode for healthy subjects and promote post-stroke patients to rehabilitate the affected limb with active participation using EMG signals 90.5% similar to those of the mirror healthy limb. The proposed method can be expected to greatly enhance power assistance and rehabilitation outcome of post-stroke patients using exoskeletons by provoking active participation. Note to Practitioners —For robotic rehabilitation, it is crucial to provide suitable assistances that can maximize the participation of post-stroke patients, which can promote the recovery outcome of therapies. The main purpose of this work is to achieve the adaptive assist-as-needed control strategy for upper limb rehabilitation tasks in two steps. Firstly, the elbow joint torques of a post-stroke patient are estimated by data fusion of motion and electromyography (EMG) signals using Kalman Filter, which can make up for the shortcomings of the individual signals, such as poor reliability and low sensitivity. Secondly, the joint motion and EMG signals of the mirror healthy limb are used as the reference to calculate the adaptive needed assistance to rehabilitate the affected limb. The preliminary experiments with healthy and post-stroke subjects demonstrate that this approach can obtain stable motion with the natural physiological states of subjects and enhance active voluntary participation in rehabilitation. In the future study, it will be investigated how to accelerate the adaptation of new patients based on the knowledge of the learned individuals using machine learning methods, such as lifelong learning and incremental learning.
4 December 2024 in IEEE Sensors Journal
Photoelectronic sensors, such as phototransistors, photoelectronic vision sensors, and photoelectronic memory elements based on low-dimensional nanomaterials and their hybrid structures, have received considerable attention for their unique structure and characteristics. Most studies on photoconductance sensors focus on positive photoconductivity (PPC); however, rare cases exist in which the conductivity decreases under light exposure. Such cases are known as negative photoconductivity (NPC). The integration of NPC and PPC has garnered significant interest for its switchable memorized electron transport mechanism, thus paving a novel way for the creation of nonvolatile memories, photoelectric logic gates, and neuromorphic computing systems. To deepen our understanding of NPC-based photoelectric sensors, we focus primarily on the basic mechanics of NPC effects and explore the related materials, structures, properties, and applications. Then, we highlight the modulation techniques for achieving NPC and PPC switching and discuss the most promising logic and memory applications by integrating the NPC and PPC effects. Furthermore, this study addresses key challenges in research on nanomaterials that exhibit NPC effects, aiming to inspire further exploration of novel, high-performance, and stable photoelectric sensors.
13 September 2023 in IEEE Transactions on Instrumentation and Measurement
Displacement sensors with subnanometer resolution and wide bandwidth are essential for micro-nano manufacturing, measurement, and motion control systems. However, the current displacement sensing methods have various limitations, such as requirements for the optical or electrical properties of the target sample, the need to be in contact with the sample surface, and the contradiction between the accuracy and bandwidth. This study proposes a displacement sensing method with wide bandwidth and subnanometer resolution, which is not only insensitive to the material properties of the measured sample but is not in contact with the sample. The squeeze film damping (SFD) force exerted on the resonant micro-cantilever plate is sensitive to the plate-sample displacement (film height), which can be converted into the cantilever vibration amplitude. The resulting amplitude variations can be measured by the optical lever method. Herein, the mathematical model of the resonant cantilever and SFD force is established. The effects of driving amplitude and frequency on displacement sensing are studied. Evidently, increasing the driving amplitude and using a resonant driving frequency can improve sensing sensitivity and resolution. Experiments reveal that the proposed method is insensitive to sample material changes, has a resolution of 0.21 nm (STD), range of 5 μm, bandwidth of about 515 Hz, and can be utilized in gantry vibration measurement.
23 March 2026 in Smart Materials and Structures
A symmetric dual-piezoelectric-actuated microgripper with an interchangeable end-effector is presented for micro/nano-manipulation. The design integrates a triangular amplification mechanism with a lever mechanism, achieving compactness and enhanced displacement transmission. Finite element analysis was employed to investigate the effects of hinge radius and structural angle on amplification ratio, natural frequency, and stress distribution: the amplification ratio increases monotonically with R, while natural frequency decreases with R, and maximum stress exhibits a nonlinear trend with a minimum at R≈0.85 mm; for θ, the amplification ratio and natural frequency first increase and then decrease (peaking at θ≈98° and θ≈96°, respectively), while maximum stress decreases nonlinearly with increasing θ. Subsequent stiffness optimization was conducted through threaded fixation, actuator interface reinforcement, and a stainless-steel sandwich housing. Experiments confirmed the effectiveness of the design. The prototype achieved a natural frequency of 1040 Hz and a displacement amplification ratio of 14.2, with maximum output obtained under a preload of 0.23 Nm. The interchangeable end-effectors have successfully demonstrated the capability to grip 88-μm wires, glass microtubes, and AFM probes. Compared with similar devices, the proposed microgripper maintains compact size while achieving higher dynamic performance, reducing resonance risk. These results highlight its potential for MEMS assembly, biological sample handling, and other precision manipulation tasks.
9 December 2024 in IEEE Transactions on Nanotechnology
Force curve is the most important techniques for accurate measuring the stiffness, adhesion and energy dissipation. However, due to the challenges of probe-cell localization, this type of single-cell analysis tool has become a labor-intensive and time-consuming procedure. Here, we demonstrate an automatic positioning methods based on micropipette for force curves acquisition. The automation covers the detection of cells in label-free images, pre-positioning and automatic focusing of micropipette, as well as automated force curves. This new method discards silicon-based probes used in traditional AFM, and instead utilizing a transparent micropipette with an unobstructed tip as the sensor. This advancement enables accurate localization of the probe tip and cell under an optical microscope. Furthermore, during the probe positioning process, we have implemented a pre-localization method using focused laser projection. This allows for manual adjustment of the probe tip within a range of 70 micrometers, providing precise region of interests (ROI) for automatic tip focusing. Combining with the aforementioned techniques. We also demonstrate the high-precision localization and force curve acquisition of eight fixed cells on a single image. The measurement results indicate that the positioning error will not exceed 3.4 μm. Our work has effectively enhanced the efficiency of cellular mechanical measurements and holds the potential to achieve automated high-throughput single-cell analysis and drug screening.