Hong Meng

Hong Meng

Auto-generated profile, based on publicly available information

Hong Meng

Department of Echocardiography, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2022 in Journal of Cardiology
Verified
Journal Article
Closed access
MLMuzi Li
Muzi Li
WHWenwen Hu
Wenwen Hu
CWCheng Wang
Cheng Wang
LWLinyuan Wan
Linyuan Wan
YLYu Liang
Yu Liang
HMHong Meng
Hong Meng

27 August 2024 in BMC Pediatrics
Verified
Journal Article
Open access
PDF file
HMHong Meng
Hong Meng
ZLZhi-Ling Luo
Zhi-Ling Luo
YSYan Shen
Yan Shen
QLQian-Qian Liu
Qian-Qian Liu
MLMu-Zi Li
Mu-Zi Li
YGYi-Ming Gao
Yi-Ming Gao
Background: Coarctation of the aorta (CoA) is the most common undiagnosed congenital heart defect during prenatal screening. High false positive and false negative rates seriously affect prenatal consultation and postnatal management. The objective of the study was to assess the utility of various measurements to predict prenatal CoA and to derive a diagnostic algorithm. Methods: One hundred and fifty-four fetuses with suspected CoA who presented at Fuwai Hospital between December 2017 and August 2021 were enrolled and divided into confirmed CoA cases (n = 47) and false positive cases (n = 107), according to their postnatal outcomes. The transverse aortic arch, isthmus, and descending aorta were measured in the long-axis view of the aortic arch. The angle between the transverse aortic arch (TAO) and the descending aortic arch (DAO) was defined as the TAO-DAO angle and measured in the long axis or sagittal view. Based on the database in GE Voluson E10 and the formula (Z = $$\frac{\text{x}-{\mu }}{\alpha }$$ ), the standard score (Z-score) of the dimensions of the aorta were calculated in relation to the gestational age. The main echocardiographic indices were combined to design a 3-step diagnostic protocol. The TAO-DAO angle was used as the first step in the diagnostic model. The diameter of the transverse arch and the Z-score of the isthmus were the second step. The third-step indices included a Z-score of the transverse arch, diameter of the isthmus, distance from the left subclavian artery (LSA) to left common carotid artery (LCCA), the ratio of isthmus diameter and LSA diameter and ratio of the distances (the distance between the LSA and LCCA to the distance between the right innominate artery and LCCA). The receiver operating characteristic (ROC) curve determined the predictive capability of each diagnostic parameter, and the kappa test determined the diagnostic accuracy of the proposed model. Results: The cases with confirmed CoA had thinner transverse arches (1.92 ± 0.32 mm vs. 3.06 ± 0.67 mm, P = 0.0001), lower Z-scores of the isthmus (-8.97 ± 1.45 vs. -5.65 ± 1.60, P = 0.0001), smaller TAO-DAO angles (105.54 ± 11.51° vs. 125.29 ± 8.97°, P = 0.0001) and larger distance between the LSA and LCCA (4.45 ± 1.75 mm vs. 2.74 ± 1.07 mm, P = 0.0001) than the false positive cases. The area under the curve (AUC) was 0.947 (95% CI 0.91–0.98) for the TAO-DAO angle ≤ 115.75°, 0.942 (95% CI 0.91–0.98) for the transverse arch diameter ≤ 2.31 mm, 0.937 (95% CI 0.90–0.98) for the Z-score of the isthmus ≤ -7.5, and 0.975 (95% CI 0.95–1.00) for the 3-step diagnostic protocol with 97.8% sensitivity and 97.2% specificity. The kappa test showed that the model’s diagnostic accuracy was consistent with postnatal outcomes (kappa value 0.936, P = 0.0001). Conclusions: The 3-step diagnostic protocol included the three most useful measurements and the additional indices with appropriate cut-off values. The algorithm is useful for the detection of aortic coarctation in fetuses with a high degree of accuracy. Trial registration: Retrospectively registered.

1 January 2022 in Congenital Heart Disease
Verified
Journal Article
Open access
PDF file
MLMuzi Li
Muzi Li
HMHong Meng
Hong Meng
LZLiang Zhang
Liang Zhang
YZYuzi Zhou
Yuzi Zhou
CLChao Liang
Chao Liang
HWHao Wang
Hao Wang
Background: Children are at risk of extubation failure after congenital heart disease surgery. Such cases should be identified to avoid possible adverse consequences of failed extubation. This study aimed to identify ultrasound predictors of successful extubation in children who underwent cardiac surgery. Methods: Children aged 3 months to 6 years who underwent cardiac surgery (if they were intubated for >6 h and underwent a spontaneous breathing trial) were included in this study. Results: We included 83 children who underwent surgery for congenital heart disease. Transthoracic echocardiography and lung ultrasound were performed immediately before spontaneous breathing trials. Upon spontaneous breathing trial completion, respiratory parameters, including arterial blood gas analysis and frequency-to-tidal volume ratio, were similarly recorded. For outcome assessment, all children were followed up for 48 h after extubation. We successfully extubated 57 children (68.7%). These children were significantly older and weighed more but had shorter aortic cross-clamp and cardiopulmonary bypass times. Children who could not be weaned or extubated had prolonged total mechanical ventilation and pediatric intensive care unit stay. In the multivariate regression analysis, a lung ultrasound score ≥12 and ejection fraction ≥40% immediately before spontaneous breathing trials were the only independent predictors of successful extubation. When combined, the lung ultrasound score and an ejection fraction ≥40% showed a better diagnostic performance than every other isolated variable (lung ultrasound, N-terminal-pro-B-type natriuretic peptide, and frequency-to-tidal volume ratio). Conclusions: The combination of lung ultrasound and transthoracic echocardiography immediately before the spontaneous breathing trial effectively predicts extubation outcomes in children after cardiac surgery.

5 June 2024 in Hellenic Journal of Cardiology
Verified
Journal Article
Open access
HMHong Meng
Hong Meng
LWLin-Yuan Wan
Lin-Yuan Wan
RQRan Qu
Ran Qu
QLQian-Qian Liu
Qian-Qian Liu
MLMu-Zi Li
Mu-Zi Li
KYKe-Ming Yang
Ke-Ming Yang
We aimed to examine bi-ventricular remodeling and function following Ebstein's anomaly (EbA) surgical correction using echocardiographic techniques, particularly the relations between the bi-ventricular changes and the EbA types. From April 2015 to August 2022, 110 patients with EbA were included in this retrospective study based on the Carpentier classification. Echocardiography assessments during the preoperative, early, and mid-term postoperative periods were performed. The 54 patients with types A and B EbA were included in group 1, whereas the 56 with types C and D were in group 2. Seventy-eight patients underwent surgical correction of EbA. The median age at operation was 8.8 years. During the mid-term follow-up, only 9.1% of the patients had moderate or severe tricuspid regurgitation. Right ventricular (RV) systolic function worsened in group 2 at discharge (fractional area change: 27.6±11.2 versus 35.4±11.5 [baseline], P<0.05; global longitudinal strain: -10.8±4.4 versus -17.9±4.7 [baseline], P=0.0001). RV function slowly recovered at a mean of 12-month follow-up. Regarding left ventricular (LV) and RV systolic function, no statistical difference was found between before and after surgery in group 1. A high success rate of surgical correction of EbA with an encouraging durability of the valve was noted. Bi-ventricular systolic function was maintained fairly in most patients with types A and B postoperatively. A late increase in RV systolic function after an initial reduction and unchanged LV systolic function were observed in the patients with types C and D postoperatively.

17 January 2025 in Medicine
Verified
Journal Article
Open access
HZhanwen zhang
hanwen zhang
QLQianqian Liu
Qianqian Liu
HMHong Meng
Hong Meng
CXChangming Xiong
Changming Xiong
Rationale: The transcatheter closure and atrioseptopexy are the main treatment methods for atrial septal defect (ASD). However, persistent hypoxemia due to iatrogenic diversion of inferior vena cava (IVC) to the left atrium (LA) is reported as a rare complication after ASD closure. Contrast echocardiology is a reliable and powerful tool to detect iatrogenic diversion and identify the etiology accurately. Patient concerns: We reported 2 patients (a 11-year-old boy [Patient 1] and a 39-year-old female [Patient 2]) with persistent hypoxemia and exertional dyspnea after ASD transcatheter closure and robotic atrioseptopexy, respectively. Diagnoses: Contrast echocardiography confirmed the presence of a right-to-left shunt at the atrial level which was presented only in femoral venous contrast injection instead of upper extremity venous contrast injection. Interventions and Outcomes: Subsequent surgical exploration found that the occluder straddling the entry of IVC and the fibrous membrane proliferating along the lower edge of the occlude in the first patient, and the patch improperly linked to the Eustachian valve in the second patient. The misoperation led to IVC partially draining into LA. After the surgeries, both of them had their hypoxic symptoms relieved. Lessons: Persistent unexplained hypoxemia after ASD closure might be considered to result from a right-to-left shunt. An iatrogenic right-to-left shunt flow from the IVC to the LA was usually caused by the misplaced interatrial occluder or patch. Transthoracic agitated saline contrast echocardiography via combined peripheral venous access has the well-performed capability to hint some insidious right-to-left shunts and guides clinical therapy as soon as possible.

1 September 2022 in Research Square
Verified
Preprint
Open access
PDF file
HMHong Meng
Hong Meng
ZLZhi-Ling Luo
Zhi-Ling Luo
YSYan Shen
Yan Shen
QLQian-Qian Liu
Qian-Qian Liu
MLMu-Zi Li
Mu-Zi Li
YGYi-Ming Gao
Yi-Ming Gao
Background Coarctation of the aorta (CoA) is the most common undiagnosed congenital heart defect during prenatal screening. High false positive and false negative rates seriously affect prenatal consultation and postnatal management. The objective of the study was to assess the utility of various measurements to predict prenatal CoA and to derive a diagnostic algorithm. Methods One hundred and fifty-four fetuses with suspected CoA who presented at Fuwai Hospital between December 2017 and August 2021 were enrolled and divided into confirmed CoA cases (47) and false-positive cases (107), according to their postnatal outcomes. Fetal echocardiographic measurements included the cardiac chambers sizes, valve annular diameters, and ascending aorta and pulmonary artery dimensions. The corresponding gestational age-related Z-scores were collected. The diameter of the transverse aortic arch and the aortic isthmus were measured. The TAO-DAO angle between the transverse aortic arch and isthmus was also measured. The receiver operating characteristic curve determined the predictive capability of each diagnostic parameter, and the kappa test determined the diagnostic accuracy of the proposed model.Results Confirmed CoA cases had thinner transverse arches (1.92 ± 0.32 mm vs. 3.06 ± 0.67 mm, P = 0.0001), lower Z-scores of the isthmus (-8.97 ± 1.45 vs. -5.65 ± 1.60, P = 0.0001), smaller TAO-DAO angles (105.54 ± 11.51° vs. 125.29 ± 8.97°, P = 0.0001) and larger distance between the left subclavian artery and left common carotid artery (4.45 ± 1.75 mm vs. 2.74 ± 1.07 mm, P = 0.0001) than the false-positive cases. The area under the curve was 0.947 (95% CI 0.91–0.98) for the TAO-DAO angle, 0.942 (95% CI 0.91–0.98) for the transverse arch diameter, and 0.937 (95% CI 0.90–0.98) for the Z-score of the isthmus. Three important echocardiographic indices were combined to derive a three-step echocardiographic diagnostic model. The kappa test showed that the model’s diagnostic accuracy was consistent with postnatal outcomes (kappa value 0.936, P = 0.0001).Conclusions The three step approach included the three most useful measurements and the five additional indices with appropriate cut-off values. The algorithm optimizes the diagnosis of fetal CoA and is clinically feasible.Trial registration: retrospectively registered.