Thamirys Cosmo Grillo Fajardo

Thamirys Cosmo Grillo Fajardo

Auto-generated profile, based on publicly available information

Thamirys Cosmo Grillo Fajardo

Pediatric Infectiology Laboratory, Pediatrics Department, Jundiaí School of Medicine, Jundiaí-SP, Brazil

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2019 in American Journal of Case Reports
Verified
Journal Article
Closed access
PDF file
AMAlexandra Siqueira Mello
Alexandra Siqueira Mello
ABAna Paula A. Pascalicchio Bertozzi
Ana Paula A. Pascalicchio Bertozzi
MRMaria Manoela D. Rodrigues
Maria Manoela D. Rodrigues
RGRosa Estela Gazeta
Rosa Estela Gazeta
AMAntônio F. Moron
Antônio F. Moron
Saulo PassosSaulo Passos
Saulo Passos
BACKGROUND:The Zika virus is an arbovirus that has as main source of transmission the bite of infected insects of the genus Aedes and has been associated with cases of congenital malformation and microcephaly in neonates. However, other sources of tr...

18 October 2020 in Jornal de Pediatria
Verified
Journal Article
Open access
Ana Paula Pascalicchio BertozziAna Paula Pascalicchio Bertozzi
Ana Paula Pascalicchio Bertozzi
RGROSA ESTELA GAZETA
ROSA ESTELA GAZETA
TFThamirys Cosmo Gillo Fajardo
Thamirys Cosmo Gillo Fajardo
AMAntonio Fernandes Moron
Antonio Fernandes Moron
ASAntoni Soriano-Arandes
Antoni Soriano-Arandes
Saulo PassosSaulo Passos
Saulo Passos
We sought to describe the prevalence of microcephaly and to compare the different cutoff points established by the Brazilian Ministry of Health at various times during a Zika virus epidemic. As a secondary aim, we investigated the possible etiology of the microcephaly. This retrospective study utilized newborn participants in the Zika Cohort Study Jundiaí. Newborns from the Zika Cohort Study Jundiaí with an accurate gestational age determination and complete anthropometric data were analyzed, and microcephaly was diagnosed according to the INTERGROWTH-21st curve. At delivery, fluids were tested for specific antibodies and for viruses. Brain images were evaluated for microcephaly. Receiver Operating Characteristic curves were plotted to define the accuracy of different cutoff points for microcephaly diagnosis. Of 462 eligible newborns, 19 (4.1%) were positive for microcephaly. Cutoff points corresponding to the curves of the World Health Organization yielded the best sensitivity and specificity. Three of the microcephaly cases (15.8%) were positive for Zika virus infections; nine (47.4%) had intrauterine growth restriction; one had intrauterine growth restriction and was exposed to Zika virus; three had a genetic syndrome (15.8%); and three had causes that had not been determined (15.8%). Microcephaly prevalence was 4.1% in this study. Cutoff values determined by the World Health Organization had the highest sensitivity and specificity in relation to the standard IG curve. The main reason for microcephaly was intrauterine growth restriction. All possible causes of microcephaly must be investigated to allow the best development of an affected baby.

30 April 2021 in Medicine
Verified
Journal Article
Open access
TFThamirys Cosmo Grillo Fajardo
Thamirys Cosmo Grillo Fajardo
RGRosa Estela Gazeta
Rosa Estela Gazeta
DCDaniel Thome Catalan
Daniel Thome Catalan
AMAlexandra Siqueira Mello
Alexandra Siqueira Mello
ASAndrea Cristina Botelho da Silva
Andrea Cristina Botelho da Silva
Saulo PassosSaulo Passos
Saulo Passos
Rationale: The chikungunya virus (CHIKV) was first isolated in a Tanzanian epidemic area between 1952 and 1953. The best description of the CHIKV transmission during pregnancy can be found in a well-documented epidemic in 2005, in the “La Reunion” island, a French territory located in the Indian Ocean, in which about one-third of the population was infected. Reports of arbovirus infections in pregnancy are increasing over time, but the spectrum of clinical findings remains an incognita among researchers, including CHIKV. Patient concerns: In this report, it was possible to verify 2 cases exposed to CHIKV during foetal period and the possible implications of the infection on gestational structures and exposed children after the birth. Diagnosis: In both cases, the mothers were positive by laboratory tests in serologic analysis for CHIKV, as ezyme-linked immunossorbent assay (ELISA), plaque reduction neutralisation testing (PRNT) and immunofluorescence (IF); but there were no positive tests in quantitative polymerase chain reaction (qPCR) for mothers or children. Interventions: The exposed children were followed up in a paediatrics clinic in order not only to provide the medical assistance, but also to verify child development and the possible implications and neurocognitive changes caused by gestational infection. Outcomes: There were neurological and developmental changes in one of the children followed up on an outpatient basis. There was an improvement in the neurological situation and symptoms only 3 years and 1 month after birth. Lessons: Based on the cases presented, we can conclude that clinical symptoms of CHIKV maternal infection may occur late in new-borns and can affect their development.

9 September 2019 in Journal of NeuroVirology
Verified
Journal Article
Open access
PDF file
DVDanila Vedovello
Danila Vedovello
SWSteven S. Witkin
Steven S. Witkin
ASAndrea Cristina Botelho Silva
Andrea Cristina Botelho Silva
TFThamirys Cosmo Gillo Fajardo
Thamirys Cosmo Gillo Fajardo
AMAlexandra Siqueira Mello
Alexandra Siqueira Mello
Saulo PassosSaulo Passos
Saulo Passos
Paired maternal and newborn urine and amniotic fluid from 138 subjects collected during a Zika virus (ZIKV) outbreak was analyzed for ZIKV by gene amplification (RT-qPCR), and the findings were correlated with clinical symptoms and neurological anomalies in the babies. ZIKV was detected in 1 of 9 symptomatic women (11.1%) and in 19 of 129 asymptomatic women (14.7%). Neurological manifestations were present in 19 babies (13.7%), 10 of 20 (50%) positive and 9 of 119 (7.6%) negative (p < 0.001) for ZIKV. Twelve (8.6%) urines collected during gestation were ZIKV-positive; only 2 remained positive for ZIKV postpartum. Six (4.1%) newborn urines collected within 1 day of delivery were ZIKV-positive cases. In 3 of these cases, ZIKV was detected in mother’s urine pre- and postpartum and in both mother’s urine and babies’ urine. Four of the amniotic fluid samples (2.9%) were ZIKV-positive. Among ZIKV-negative babies with neurological sequel, 87.5% were female; in contrast, 72.7% ZIKV-positive babies with neurological abnormalities were male (p = 0.019). We conclude that during a ZIKV outbreak, clinical symptoms and ZIKV detection in biological fluids are poor predictors of infection and adverse neurologic sequel in newborns.

3 January 2023 in Acta Oto-Laryngologica
Verified
Journal Article
Open access
RPRaquel Prestes
Raquel Prestes
VPViviane Cristina Martori Pandini
Viviane Cristina Martori Pandini
TPTânia Pereira
Tânia Pereira
MPMarisa Cavenaghi Argentino Pomilio
Marisa Cavenaghi Argentino Pomilio
AAAdriana Neves de Andrade
Adriana Neves de Andrade
Saulo PassosSaulo Passos
Saulo Passos
Zika virus (ZIKV) infection can result in hearing loss in babies, consequently, audiological monitoring is necessary.This study aimed to evaluate the frequency of hearing impairment in neonates and... 背景:寨卡病毒 (ZIKV) 感染可导致婴儿听力损失, 因此, 听力检控是必要的。目的:本研究旨在评估宫内期间暴露于寨卡病毒的新生儿和儿童听力障碍的频率。材料和方法:在怀孕期间(2016 年 3 月至 2017 年 1 月)感染寨卡病毒的母亲所生的 30 名儿童在出生后 48 小时接受了反复的听力评估。 通用新生儿听力筛查显示所有儿童在 6 个月、13 个月、24 个月和36个月时结果正常。...

7 July 2025
Verified
Journal Article
Open access
TFThamirys Cosmo Grillo Fajardo
Thamirys Cosmo Grillo Fajardo
AQAntonio Carlos de Quadros
Antonio Carlos de Quadros
CPClóvis Antonio Lopes Pinto
Clóvis Antonio Lopes Pinto
GSGeovane Ribeiro Dos Santos
Geovane Ribeiro Dos Santos
ASAndrea Cristina Botelho da Silva
Andrea Cristina Botelho da Silva
AMAlexandra Siqueira Mello
Alexandra Siqueira Mello
Evidence suggests a risk of maternal transmission of chikungunya virus (CHIKV) during the first and third trimesters, potentially leading to miscarriage or neurological consequences for the fetus. This study aimed to conduct a serological survey for CHIKV among women with high-risk pregnancies and analyze neonatal variables and placental tissue alterations. From March 2016 to April 2021, serological, histological, and molecular tests for CHIKV were performed. Blood samples were analyzed for anti-CHIKV IgG and IgM antibodies, and placental tissue was examined for CHIKV RNA and histological changes. Among pregnant patients, 1.33% (7/526) had reactive IgG, and 0.38% (2/526) had IgM/IgG-type antibodies during delivery. Although placental histology of CHIKV disease showed alterations, no viral genetic material was identified in the analyzed tissues. Therefore, further research is needed, including the use of complementary diagnostic techniques, to better understand the impact of this relatively new disease among high-risk pregnant women and newborns.