2 May 2023 in IEEE Transactions on Electron Devices
Herein, we present a detailed analysis of the effects of O2 plasma treatment on the AlGaN barrier volume trap states in an Al0.45Ga0.45N/GaN high-electron mobility transistor. Compared to that of the as-grown sample, the single short-pulse ${I}_{D}$ – ${V}_{\text {GS}}$ characterization of the plasma-treated sample exhibited lower charge trapping inside the AlGaN barrier. The 1/ ${f}$ low-frequency noise characterization revealed a significant reduction of approximately 67% in the volume trap density of the AlGaN barrier layer after O2 plasma treatment. This was achieved by the formation of Al–O and Ga–O bonds via the penetration of oxygen ions into the AlGaN bulk, which resulted in reduced trap state density in the AlGaN barrier. In addition, the Schottky characteristics were improved notably. Consequently, the O2 plasma-treated sample did not display current collapse and showed steady drain current output under the reverse-sweep drain-stress bias conditions. Furthermore, the plasma treatment significantly reduced the RF transconductance ( ${g}_{m}$ ) collapse in the as-grown sample, and significantly increased the ${f}_{T}/{f}_{\text {max}}$ of the plasma-treated sample from 65/70 to 120/230 GHz for ${L}_{g}$ = 80 nm devices, respectively. Last, the O2 plasma-treated sample showed substantial improvements in ${P}_{\text {out}\_\max}$ , power added efficiency (PAE), and linear gain from 1.25 W/mm, 20%, and 15 dB to 2.4 W/mm, 50%, and 19 dB, respectively.
24 December 2010 in Applied Physics Express
16 November 2021 in IEEE Journal of the Electron Devices Society
We have studied the effects of proton irradiation on the AlGaN/GaN HEMTs with AlN buffer layer as well as conventional GaN buffer layer. It was found that a short time proton irradiation (~ 50 sec) can promote beneficial effects on device performances, which results in great reduction in the off-state leakage current and the gate leakage current without degrading the output current and transconductance. The pulsed I-V measurement demonstrated that both devices exhibit greatly improved current dispersion characteristics and, particularly, the device with AlN buffer layer shows stronger radiation hardness than that of the device with GaN buffer layer. These interesting results are believed to be due to the hydrogen passivation with thermal annealing effect during the proton irradiation. It is expected that the proper irradiation condition such as fluence, energy, and time is crucial to improve the device performances, rather than to deteriorate the performances.
2 December 2021 in Scientific Reports