10 August 2024 in Expert Systems with Applications
12 April 2025 in Medical Image Analysis
23 January 2025 in Expert Systems with Applications
30 September 2024 in IEEE Transactions on Biomedical Engineering
Objective: Fractional flow reserve (FFR) derived from coronary angiography, referred to as ICA-FFR, is a less-invasive alternative for invasive FFR measurement based on computational fluid dynamics. Blood flow into side branches influences the accuracy of ICA-FFR. However, properly compensating for side branch flow in ICA-FFR analysis is challenging. In this study, we proposed a physiological side branch flow model to comprehensively compensate side branch flow for ICA-FFR analysis with no need for reconstructing side branch geometry. Methodology: the physiological side branch flow model employed a reduced-order model to calculate the pressure distribution in vessel segments. The main coronary artery (without side branches) was delineated and divided based on bifurcation nodes. The model compensates for flow to invisible side branches within each segment and flow to visible side branches at each bifurcation node. Lastly, ICA-FFR based on physiological side branch flow model (ICA-FFR$\rm _{PSBF}$) was calculated from a single angiographic view. Functional stenosis is defined by FFR $\leq$ 0.80. Result: Our study involved 223 vessels from 172 patients. Using invasive FFR as a reference, the Pearson correlation coefficient of ICA-FFR$\rm _{PSBF}$ was 0.93. ICA-FFR$\rm _{PSBF}$ showed a high AUC (AUC = 0.96) and accuracy (91.9$\%$) in predicting functional stenosis. Conclusion: The proposed model accurately compensates for flow to side branches without their geometry in ICA-FFR analysis. ICA-FFR analysis exhibits high feasibility and diagnostic performance in identifying functional stenosis.
7 October 2025 in IEEE Transactions on Medical Imaging
As a leading global cause of mortality, coronary ischemia requires accurate diagnostics for effective management. The combining coronary angiography with fractional flow reserve (FFR) offers structural and functional assessment of coronary stenosis to guide revascularization. However, traditional FFR measurements are invasive, requiring pressure wire placement. Image-based FFR estimation methods integrate vascular morphology with biomechanics but face challenges in modelling the complex fluid-structure interaction (FSI) of coronary flow and vessel walls. Therefore, we propose a physics-guided variational domain progressing method (PVDPM) for non-invasive FFR estimation through FSI system. PVDPM employs the principle of virtual work to model FSI system. This approach can improve the modelling of interdependent physical processes, enabling accurate FFR estimation based on coronary angiography-derived vascular morphology. The PVDPM demonstrates 91% accuracy in clinical datasets and offers solution for diagnosing coronary ischemia based on coronary angiography.
24 August 2026 in SSRN Electronic Journal
The growing energy and carbon footprint of large-scale radio access network (RAN) has made green operation an increasingly important infrastructure-level problem. Existing research has advanced downstream energy-saving control, yet comparatively less attention has been paid to upstream decisions on where limited operational resources and energy-saving capabilities should be deployed. A key challenge is that energy, traffic, spatial coverage, and technical--operational features are heterogeneous in form and difficult to compare within a unified cell-level decision space. This paper proposes an interpretable, decision-conditioned operational-value profiling and prioritization framework for upstream green RAN decision support. It transforms heterogeneous historical evidence into comparable cell-level value representations and adapts priority formation to decision contexts and resource constraints. The framework is evaluated using two years of real commercial-network data covering 19,796 cells and 403,602 directed coverage relationships. Seven rolling 90-day out-of-time cycles provide large-scale offline validation across changing network conditions. Relative to the operator rule, the proposed method increases the eligible-cohort deployment rate by 10.2 percentage points and cell-averaged energy saving by 29.8\%, while reducing four operational-risk rates by 1.99--3.37 percentage points. Live deployments in ten preselected high-complexity multi-coverage regions further preserve the expected improvement directions in benefit, risk control, and overall operational value. These results indicate that upstream operational-value prioritization can improve resource allocation and role coordination in complex RAN environments and provide actionable guidance for downstream green control.