16 January 2024 in IEEE Transactions on Biomedical Circuits and Systems
This paper presents the system architecture for an implant concept called NeuroBus . Tiny distributed direct digitizing neural recorder ASICs on an ultra-flexible polyimide substrate are connected in a bus-like structure, allowing short connections between electrode and recording front-end with low wiring effort and high customizability. The small size (344 μm x 294 μm) of the ASICs and the ultraflexible substrate allow a low bending stiffness, enabling the implant to adapt to the curvature of the brain and achieving high structural biocompatibility. We introduce the architecture, the integrated building blocks, and the post-CMOS processes required to realize a NeuroBus , and we characterize the prototyped direct digitizing neural recorder front-end as well as polyimide-based ECoG brain interface. A rodent animal model is further used to validate the joint capability of the recording front-end and thin-film electrode array.
22 May 2025 in Nature Communications
Advancements in the field of implantable neurotechnologies have enabled the integration of hundreds of microelectrodes on ultra-thin and flexible substrates. Besides implantable components, also connectors, headstages and cables have to comply with the high-count demand, resulting in a complex and compact chain with reduced line spacing and smaller safety margins. Here, we show that epicortical recordings acquired from anesthetized rat brains with a state-of-art neural acquisition system are undoubtedly compromised by crosstalk, with signal coherence maps exhibiting a strong dependency to the routing layout. A crosstalk back-correction algorithm is developed, allowing to infer on how signals would look like under a zero-crosstalk scenario. We found that signal coherence between closely routed channels effectively drops after correction, corroborating crosstalk contamination. Our work stresses the importance of validating recorded data against the routing layout as a crucial step of data quality control, helping to come closer to ground truth data.
1 August 2026 in IEEE Transactions on Biomedical Engineering
Objective: Decades of studies have enabled a constant optimization of thin-film-based neural implants, with technologies designed to adapt to the biological surroundings through biocompatible and miniaturized materials. Careful assessment of these materials is essential prior to photolithographic fabrication of multilayered devices, as delamination from adhesion mismatches between neighboring layers can compromise recording or stimulation and lead to channel crosstalk or device failure. Multi-layer interactions are therefore closely examined to tailor devices for long-term stability, yet post-implantation examinations still reveal failure modes that are not fully addressed and understood. Here, we propose an in vitro investigation of polyimide (PI), a widely used substrate material, in a simplified single layer configuration, to isolate substrate-related effects and evaluate long-term stability under combined conditions that cover not only the implantation period, but also post-implantation steps. Methods: Accelerated ageing was used to mimic processes occurring in the brain during implantation while aged samples were also exposed to aldehyde-based fixation and storage conditions commonly encountered during post-mortem processing. Surface morphology was assessed using Scanning Electron Microscopy (SEM). Chemical microstructure was analyzed in a dual approach using Time-of-Flight-Secondary-Ion Mass-Spectroscopy (ToF-SIMS) and Fourier Transform Infrared Spectroscopy (FTIR). Conclusion: PI remains morphologically and chemically stable under the harshest conditions, in both implantation scenarios and subsequent post-implantation steps. Significance: These findings provide critical validation for the use of PI as a durable substrate in long-term neural interfaces. They further indicate that damage observed after implantation may arise from factors beyond intrinsic PI degradation, helping prevent misinterpretation during post-implantation analysis.