Grid-tied inverter performance is degraded by its inherent nonlinear characteristics, which can be suppressed by internal model principle-based controllers. However, designing these controllers requires a tradeoff between time consumption and model uncertainties. This paper proposes a data-driven approach that can eliminate the influences of nonlinearities and improve grid-tied inverter performance by compensating for low-frequency harmonics, enhancing current control accuracy and improving system stability. The proposed data-driven compensation method trains data based on the internal model principle, establishes a data regression model through lightweight offline regression, and constructs a compensation loop based on the regression model. The loop is then combined with traditional low-order control methods to improve the overall performance of the inverters through real-time compensation. A loss function is used to validate the accuracy of the data regression model, and experimental results show the effectiveness and exceptional performance of the proposed method.
Nonlinearities of inductor’s soft magnet, converter’s time-varying mode and control delays limit the grid-side power quality improvement capability of interleaved boost Power Factor Correction (PFC) circuit. The traditional internal model principle-based approaches are widely used to improve the power quality, but the expense is the reduce of certain stability. Hence, this paper proposes a data-driven online compensation method to address this trade-off between control accuracy, power quality and stable margin. This method involves recording control data of a multi-frequency proportional resonant (PR) controller under various input conditions. The collected data is preprocessed and used to establish a regression compensation model through multivariate nonlinear regression. Finally, this regression model is applied to the compensation loop of a lower-order controller to improve power quality of the PFC while ensuring sufficient stable margin. Experiments verify the practical feasibility and the effectiveness of the proposed data-driven control method.
22 September 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
High frequency phase compensation algorithm (HFPC) is proposed in this paper to improve the stability margin of LCL filter-based grid-connected converters under converter current feedback control (CCF). To reveal the impact of different state feedback on the system’s operational characteristics, a discrete state-space model considering digital control delay has been established. On this basis, the stability range of CCF control has been determined. Accordingly, a linear predictor (LP)-based compensation method is proposed to improve the stability margin of the CCF system, and its operation mechanism and limitations are both studied as well. HFPC, including improved phase compensation (IPC) and current reconstruction (CR), is employed to further enhance the phase compensation performance of LP. Specifically, IPC is implemented to alleviate the high frequency open-loop gain caused by traditional methods such as LP, thus expanding the gain margin. CR can push the critical crossover frequency to a higher frequency band, thereby enhancing the system’s stability margin and improving current quality. The experimental results clearly validate the correctness and feasibility of the proposed method.
1 April 2026 in IEEE Transactions on Industrial Electronics
Conventional finite control set model predictive control (FCS-MPC) is widely employed in grid-connected inverters for fast and accurate grid current tracking. However, in practical applications, factors such as parameter mismatch, unmodeled dynamics, and external disturbances frequently cause model mismatch, thereby degrading control performance. To address this problem, this article proposes a data-driven high-order model-free adaptive iterative learning predictive control (HOMFAILPC), which integrates the advantages of model-free adaptive control and FCS-MPC, and incorporates the iterative learning mechanism. The proposed HOMFAILPC aims to overcome the inherent limitations of conventional FCS-MPC regarding model fault tolerance and parametric robustness. Specifically, the proposed framework relies solely on the input-output data of the controlled system, dispensing with the need for any explicit or implicit model information. A high-order iterative data-driven model is first established through dynamic linearization and then integrated with FCS-MPC to form a data-driven predictive control for optimal control actions. The proposed method effectively reduces tracking errors and enhances robustness against parameter drift, model uncertainties, and external disturbances. Simulation and experimental results are presented to validate the feasibility and effectiveness of the proposed approach.
4 March 2026 in IEEE Transactions on Power Electronics
Data-driven regression compensation control effectively mitigates the inherent nonlinearities in grid-connected inverters. However, the structural limitations inherent to the single-data regression model challenge the balance between minimal data requirements and adaptive optimization, thereby constraining compensation precision and generalization capability. To overcome the generalization limitations of the single-data model, this paper proposes a collaborative compensation control strategy based on multi-data regression models, which employs adaptive weighting for dynamic model fusion. This method integrates techniques for operating interval and boundary feature extraction to construct multi-data regression models using lightweight offline regression. Real-time matching of operating features enables dynamic model selection and weight assignment, thereby accurately reconstructing the compensation signal in extrapolation regions beyond the training data boundaries. Furthermore, by integrating with a low-order controller, a hybrid control architecture merging the mechanism-based and data-driven paradigms is established, significantly enhancing the adaptive compensation performance. Experimental results validate the effectiveness and superiority of the proposed strategy.