The dual observation of periodic and aperiodic interferences cannot be balanced by traditional linear extended state observer (T-LESO). Therefore, the speed fluctuations caused by uncertain periodic and aperiodic interferences in the interior permanent magnet synchronous motor control system cannot be suppressed by the traditional linear active disturbance rejection controller. To resolve the aforementioned problem, an improved linear active disturbance rejection controller (I-LADRC) in which multifrequency quasi-resonant filtering decoupling linear extended state observer and generalized linear extended state observer (G-LESO) are cascaded is proposed. In this controller, the interference feedforward control method of T-LESO is first changed, the observer bandwidth ωo and controller bandwidth ωc in the transfer function based on the interference term are decoupled from each other, reducing the difficulty of parameter tuning. On this basis, a multifrequency quasi-resonant filter is embedded in the decoupled linear extended state observer (LESO), so that periodic interferences can be accurately observed. For G-LESO, a fourth-order LESO is adopted to enable more accurate observation of aperiodic high-order interferences. The outer loop controller based on I-LADRC is designed, and the correctness and effectiveness of this method are verified through experiments.
1 April 2025 in IEEE Transactions on Power Electronics
The electrolytic capacitorless driver has a longer service life and higher reliability than traditional permanent magnet synchronous motor (PMSM) drivers. However, the ac component in the dc-link voltage will generate corresponding harmonics in the back electromotive force (BEMF), which will reduce the control accuracy of sensorless. The traditional extended state observer exhibits low-pass filtering characteristics, making it difficult to accurately estimate the BEMF that varies sinusoidally and effectively suppress the BEMF harmonics. Therefore, a multiharmonics suppression backstepping extended state observer (M-BESO) is proposed in this article. The BESO is designed in reverse according to the amplitude frequency characteristics of the bandpass filter, so that the center frequency changes with the motor frequency. Then, the complex coefficient module is introduced into the structure of BESO to eliminate the harmonics in the BEMF caused by the fluctuation component of the dc-link voltage. To mitigate the position estimation error when the motor speed changes rapidly, an improved phase locked loop based on third-order extended state observer is designed. Finally, the proposed method is verified on a self-built experimental platform based on the PMSM electrolytic capacitorless drives.
This article introduces a new control strategy for a bidirectional DC/DC converter used in photovoltaic energy storage systems (PV-ESSs), aimed to address the DC bus voltage deviation problem. The purpose of this paper is to design and practically implement a robust continuous control set predictive current control (CCS-PCC) method based on a nonlinear disturbance observer (NDO) to tightly regulate the common DC bus voltage in islanded DC microgrids. The CCS-PCC controller is used to replace the current loop PI controller, which effectively overcomes the shortcomings of the traditional linear lag control and improves the dynamic performance of the system. At the same time, the CCS-PCC method solves the inherent defect of finite control set predictive current control (FCS-PCC), where the switching frequency is not fixed. It effectively reduces the current ripple and realizes constant frequency control. In order to effectively suppress the DC bus voltage fluctuation during transients, the nonlinear disturbance observer is designed and combined with CCS-PCC. The feedforward method based on the NDO was utilized to enhance the disturbance rejection capability of the system. The simulation and experimental results show the feasibility and effectiveness of the proposed CCS-PCC+NDO approach, both during transient and steady-state operating conditions.
22 November 2024 in IEEE Transactions on Power Electronics
Grid-tied inverter performance is degraded by its inherent nonlinear characteristics, which can be suppressed by internal model principle-based controllers. However, designing these controllers requires a tradeoff between time consumption and model uncertainties. This paper proposes a data-driven approach that can eliminate the influences of nonlinearities and improve grid-tied inverter performance by compensating for low-frequency harmonics, enhancing current control accuracy and improving system stability. The proposed data-driven compensation method trains data based on the internal model principle, establishes a data regression model through lightweight offline regression, and constructs a compensation loop based on the regression model. The loop is then combined with traditional low-order control methods to improve the overall performance of the inverters through real-time compensation. A loss function is used to validate the accuracy of the data regression model, and experimental results show the effectiveness and exceptional performance of the proposed method.
31 December 2024 in IEEE Transactions on Industrial Electronics
The double closed-loop architecture is a universal control structure for speed servo systems. However, in multiloop architecture, the inner-loop limits the response speed of the outer-loop. To this end, a finite-time control strategy suitable for the speed current single-loop control structure is proposed to enhance the dynamic performance of the overall loop. First, compared with the dual-loop architecture, single-loop state estimator needs to be designed with higher order, which will lead to a larger estimation peak. Meanwhile, the estimation pressure of single-loop estimator is higher due to the need to consider both matched and unmatched disturbances. Therefore, a hybrid cascaded finite-time state estimator is proposed to alleviate the estimation pressure and peak phenomenon. In addition, the high-order finite-time state estimator uses only the low-order state estimation error for feedback adjustment when estimating the high-order state, and the output speed of the estimator is limited due to the output value passing through the pure integrator. Consequently, a hybrid cascaded differential compensation finite-time composite controller is further proposed to enhance the performance of the control system. Finally, the effectiveness and superiority of the proposed method were experimentally verified.
Nonlinearities of inductor’s soft magnet, converter’s time-varying mode and control delays limit the grid-side power quality improvement capability of interleaved boost Power Factor Correction (PFC) circuit. The traditional internal model principle-based approaches are widely used to improve the power quality, but the expense is the reduce of certain stability. Hence, this paper proposes a data-driven online compensation method to address this trade-off between control accuracy, power quality and stable margin. This method involves recording control data of a multi-frequency proportional resonant (PR) controller under various input conditions. The collected data is preprocessed and used to establish a regression compensation model through multivariate nonlinear regression. Finally, this regression model is applied to the compensation loop of a lower-order controller to improve power quality of the PFC while ensuring sufficient stable margin. Experiments verify the practical feasibility and the effectiveness of the proposed data-driven control method.