Tae Ho Jang

Tae Ho Jang

Auto-generated profile, based on publicly available information

Tae Ho Jang

Interdisciplinary Program, Bioengineering Major, Graduate School, Seoul National University

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2026 in PLOS ONE
Verified
Journal Article
Open access
PDF file
EYEuntaek Yoon
Euntaek Yoon
SLSung Hyun Lee
Sung Hyun Lee
HJHyeongmin Jin
Hyeongmin Jin
TJTae Ho Jang
Tae Ho Jang
SYSungjin Yoon
Sungjin Yoon
JPJong Min Park
Jong Min Park
Purpose: To evaluate the impact of stopping-power ratio (SPR) predictions derived from dual-layer detector-based spectral CT (DLCT) on conventional single-energy CT (SECT)-based carbon-ion treatment planning for thoracic cancer. Methods: Twenty patients with thoracic cancer who underwent non-contrast DLCT were retrospectively included. DLCT-based SPR images were generated from effective atomic number and relative electron density maps using the Bethe equation. SECT-based SPR was derived using a Hounsfield unit look-up table generated via stoichiometric calibration of a commercial electron density phantom. Using the same phantom, a phantom-based prediction assessment was performed by comparing SECT- and DLCT-based SPR predictions with theoretical SPR values for the inserts. For patient analysis, normal-tissue SPR values derived from SECT and DLCT were compared. Carbon-ion treatment plans were first generated based on SECT images and then recalculated using DLCT-derived SPR images. Range differences in the beam’s-eye view and dose–volume histogram parameters for the planning target volume and organs at risk were evaluated. Results: In the phantom-based assessment, the root-mean-square error relative to the theoretical SPR was 5.57% for SECT and 2.83% for DLCT. In patient images, mean SPR differences between SECT and DLCT were 3.62% for the lungs, 1.93% for the esophagus, 0.04% for the heart, 0.93% for the spinal cord, and 1.53% for the ribs. Across the patient cohort, the mean recalculated range difference was 0.71 ± 0.89 mm, corresponding to a relative difference of 0.60 ± 0.67%. No statistically significant differences were observed in target dose metrics, whereas selected organ-at-risk metrics showed statistically significant differences between SECT-based plans and DLCT-based recalculations. Conclusion: DLCT-derived SPR prediction showed better agreement with theoretical phantom SPR values in the phantom-based prediction assessment and produced tissue-dependent SPR differences in thoracic patient images compared with conventional SECT-based prediction. Recalculation on DLCT-derived SPR maps resulted in modest but systematic range differences and limited changes in selected dose metrics. These results may inform the implementation and future independent validation of patient-specific DLCT-based SPR workflows in carbon-ion treatment planning for thoracic cancer.

9 April 2026 in Physics in Medicine & Biology
Verified
Journal Article
Open access
TJTaeho Jang
Taeho Jang
HCHyung Jin Choun
Hyung Jin Choun
EYEuntaek Yoon
Euntaek Yoon
SLSung Hyun Lee
Sung Hyun Lee
JPJong Min Park
Jong Min Park
Objective. Accurate estimation of cell survival fractions across a broad range of linear energy transfer (LET) is essential for precise heavy ion therapy planning. The microdosimetric kinetic (MK) model predicts cell survival from microdosimetric quantities; however, most closed-form MK formulations treat the quadratic coefficient β as a constant, which limits predictive accuracy under high-LET irradiation. This study aimed to develop a revised MK model that overcomes this limitation by redefining β as an LET-dependent function. Approach. The revised MK model incorporates the saturation-corrected dose-mean specific energy into the formulation of β. Model performance was evaluated against the reference MK model using 324 reconstructed survival fraction data points from 54 irradiation conditions of aerobic human salivary gland tumor cells exposed to helium, carbon, and neon ions. Parameter estimation was performed using a log-scaled mean squared error loss optimized through a hybrid global–local scheme. Main results. At low LET, both the revised and reference models reproduced experimental survival with comparable accuracy. However, at higher LET, the revised model maintained stable agreement with experimental data, whereas the reference model diverged markedly due to excessive curvature in its predictions. Across the entire experimental LET range, the revised model consistently reproduced cell survival data more accurately than the reference model. Significance. These findings demonstrate that redefining the quadratic coefficient as an LET-dependent term substantially improves the predictive accuracy of the MK model under high-LET and wide-dose conditions. The proposed model enhances radiobiological modeling performance while preserving the structural simplicity and compatibility of the existing MK framework.