13 August 2018 in IEEE Transactions on Magnetics
DC bias in power transformers leads to strong core saturation and thus nonlinearly inferior operation. This paper analyzes the ability of power transformers to withstand the dc bias by novel analytical criteria. The proposed criteria are obtained from the nonlinear equivalent circuit, which considers the effects of nonlinear inductances. The validity of the proposed analytical criteria is verified by the finite-element analysis results and experimental results, which indicates that the proposed analytical criteria are effective to evaluate the ability to withstand the dc bias of power transformers.
18 December 2018 in IEEE Transactions on Magnetics
28 September 2018 in IEEE Transactions on Magnetics
The nonlinear ac-dc composite electric field in the winding area of the converter transformer was studied by considering the frequency and temperature dependence of the insulation materials in this paper. First, the relative permittivity and conductivity of vegetable oils, mineral oils, and insulation papers were measured at different frequencies and temperatures. Then, the oil-paper insulation structure model of one 500 kV converter transformer valve-side winding was established. The nonlinear composite electric field of the converter transformer insulation with vegetable oils and mineral oils was analyzed. The maximum voltage of the converter transformer with mineral oils is 524.9 kV, at -20 °C and that with vegetable oils is 497.1 kV. The results show that the calculation method proposed in this paper is more accurate than the traditional superposition method.
25 April 2019 in IEEE Transactions on Magnetics
According to the incomplete technical features of the traditional low-frequency transformer (LFT) and the existing power electronic transformer (PET), especially in terms of the function, the voltage level, and the cost, the core flux modulation of the hybrid transformer was achieved through the establishment of auxiliary windings combined with connection of the power electronic converter (PEC). For the hybrid transformer, a three-port converter topology is proposed and the strategy applicable for the dc bias compensation by connecting the converter is presented. By utilizing the dc modulation magnetic flux, the dc bias problem could be directionally compensated. The exciting current could be improved significantly and maintained at a steady state. The method proposed does not change the connection of the transformer external circuit and does not increase the peripheral device of the transformer, which provides a new way to solve the problems of magnetic state fluctuation and excitation current distortion.
23 January 2023 in IEEE Transactions on Magnetics
An element-by-element finite element method (EBE-FEM) for coupling fields and circuits is presented. EBE-FEM is a parallel algorithm in which large-scale global computations are decomposed into mutually independent local computations without assembling the global coefficient matrix. The electromagnetic correlation matrix is proposed to establish the relationship between each element and the whole domain in the magnetic field equation and the relationship between element and branch in circuit equation, which is composed by node transition matrix and branch transition matrix. The proposed method has been validated and applied to analyze the magnetic field and currents of a transformer.