To reduce the current ripples of finite control set model predictive control, this paper proposes a continuous voltage vector model-free predictive current control method for the surface mounted permanent magnet synchronous motor (SMPMSM). In the proposed method, the continuous phase and the amplitude of the voltage vector are optimized in a sequence based on their uncoupling feature, and then the steady-state current fluctuation can be reduced. Only six active voltage vectors are enumerated, and the optimal phase is obtained by establishing the Lagrange interpolation polynomial between the cost function and the phase of voltage vectors. Then, the amplitude of the voltage vector with the optimal phase is optimized based on the principle of minimizing the cost function, and the optimal voltage vector is synthesized by a three-vector method. In addition, the ultra-local model of the SMPMSM drive system from the previous study is used to improve the robustness of the proposed method. The current dynamic and steady-state responses are demonstrated through the simulation and experimental results.
A modulated model-free predictive control with minimum switching losses (MSL-MMFPC) is proposed to improve the steady-state performance and reduce the switching losses for a permanent magnet synchronous motor (PMSM) drive system. Firstly, two adjacent current vectors are determined based on the predefined first-level cost function, and then, make the current vector at the next control period equal to the reference current vector by modulating the selected current vectors properly. Additionally, in order to keep optimal control performance also in the over-modulation region, a new rotating coordinate frame is used to adjust the optimal voltage vector. Then, the second-level cost function is designed to select the optimal voltage vector sequence, so that the switching of a VSI leg does not happen during the phase-current maximum, which can reduce the switching losses of the inverter. The simulation and experimental results verify the effectiveness of the proposed control method.
18 June 2021 in IEEE Transactions on Energy Conversion
The cascaded structure is generally adopted in the permanent magnet synchronous motor drive system, however, the speed dynamic performance is always deteriorated due to the limited bandwidth of speed loop when the linear controller is employed. Therefore, in order to realize quick dynamic response, the speed loop is eliminated in the non-cascaded control structure, and the non-cascaded model-free predictive speed control is proposed in this paper. First, the ultra-local model of SMPMSM drive system is established with a compound variable which implicitly unifies the speed and current of different time scales, and then the Lyapunov function is designed to derive control law and generate the inverter reference voltage automatically by considering the delay of digital control. Moreover, the inverter reference voltage is further modified under voltage and current constraints to guarantee system safety and reliable operation. Finally, the feasibility and validity of the proposed method has been verified by system simulation and experimental researches.
1 March 2022 in IEEE Transactions on Power Electronics
The model predictive direct speed control (MPDSC) can improve the speed dynamic performance effectively. However, due to the large difference between the mechanical and electrical time constants, short prediction could result in large current ripples at steady state, which becomes a critical problem. Besides, the conventional MPDSC methods have not deeply investigated the online-adjustable weighting factor design and the problem of id transient oscillation. In this article, a model predictive direct speed control with novel cost function is proposed. In the proposed method, two different q -axis current references are generated, one to improve the speed dynamics, and the other to ensure the low current ripples. The two current tracking are assigned with different weighting factors unified in one cost function. In order to determine which current tracking to play a major role under different operations, the speed error is designed as weighting factor. With the proposed cost function and designed weighting factor, the high speed dynamics and low steady current ripples can be achieved simultaneously. Finally, the effectiveness of proposed method is verified by experiments.
23 May 2022 in IEEE Transactions on Power Electronics
Conventionally, the benchmark proportional-integral control method is implemented to realize power factor correction and output voltage regulation of single-phase ac/dc converters. However, the performance is deteriorated due to the influence of uncertainties and disturbances, e.g., periodic input voltage and load variation. Concerning this problem, this article proposes a model-free control (MFC) strategy of single-phase ac/dc converters. The MFC principle is revisited and a frequency response analysis is presented for the algebraic estimators of uncertainties and disturbances. Consequently, the closed-loop performance of MFC systems is allowed to be analyzed in frequency domain via classical linear control theory. Based on the theoretical results, the model-free current and voltage control systems are synthesized in detail to achieve control objectives of the converter. Simulation results demonstrate the performance of MFC systems in reference tracking and disturbance rejection. The feasibility and validity of the presented MFC strategy for single-phase boost ac/dc converters is also confirmed experimentally as compared to the benchmark scheme.
7 January 2019 in Journal of Electrical Engineering & Technology