13 January 2025 in IEEE Transactions on Instrumentation and Measurement
This paper develops an electrostatic device (ESD) tester with particularly high sensitivity for the charged device model (CDM) by incorporating empirical equivalent circuit (EC) parameters. The tester is implemented by using software and hardware system based on the STM32® microcontroller The tester feasibility study involves circuit theoretical analysis and simulation enabling to investigate the influence of EC parameters on the discharge signal waveform. High-precision and automated ESD sensitivity are utilized to develop the proposed testing system. As proof of concept, various common electronic components are tested. The performed experiment reveals that the CDM discharge signal is influenced not only by the DUT’s capacitance, but also by the packaging structure and pins for different functions. The explored measurement results highlight the importance of considering different pins for electronic device ESD protection neasures. The present study is industrially useful to enhance the ESD immunity during the design of electronic devices or chips by considering their circuit connections.
26 December 2022 in IEEE Transactions on Instrumentation and Measurement
To study the risk of electrostatic discharge (ESD) caused by human activities in an electrostatic protected area (EPA), an innovative contact mode human body (HB) dynamic potentiometer is designed. It uses a coaxial capacitor voltage divider (CVD) to achieve high accuracy performance. The temperature, coaxial capacitor medium thickness, and relative position effects on the CVD performance are simulated and measured. It utilizes LabVIEW development software to realize data visualization, analysis, and dynamic display of time-domain waveforms. The HB dynamic potentiometer test results show that the voltage measurement range is 0~±6 kV, the measurement error lower than 1 kV is better than 2%, the system response time is less than 1 ms, and the passband is better than 1 kHz. Using this potentiometer, the voltage generated by HB in different modes of action in the EPA was studied, for example, the cases of walking in a fixed pattern, walking randomly, and raising and lowering the feet. The ESD voltage is predicted by using the Chebyshev inequality over a long-time duration, which corresponds to 2-3 times the measured voltage over a short time duration. This study found that compared to the pattern walk motion, the random walk increases the HB model (HBM) voltage by a factor of 1.5 to 2. The foot lifting activity can increase the voltage by a factor of 8 to 12. Finally, the relative humidity decreased from 45% to 30% by increasing the HBM voltage by a factor of 2 to 3 for both walking and foot lifting and lowering motion. This result can be used to support the electrostatic protection standard in the EPA.