Mikkel Schou

Mikkel Schou

Auto-generated profile, based on publicly available information

Mikkel Schou

Department of Health Technology, Center for Fast Ultrasound Imaging, Technical University of Denmark, Lyngby, Denmark

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
MSMikkel Schou
Mikkel Schou
LJLasse Thurmann Jorgensen
Lasse Thurmann Jorgensen
BTBorislav G. Tomov
Borislav G. Tomov
MSMatthias Bo Stuart
Matthias Bo Stuart
CSCharlotte M. Sørensen
Charlotte M. Sørensen
Row–column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article summarizes the current literature for RC imaging and demonstrates that full anatomic and functional imaging can attain a high quality using synthetic aperture (SA) sequences and modified delay-and-sum beamforming. Resolution can approach the diffraction limit with an isotropic resolution of half a wavelength with low sidelobe levels, and the field of view can be expanded by using convex or lensed RC probes. GPU beamforming allows for three orthogonal planes to be beamformed at 30 Hz, providing near real-time imaging ideal for positioning the probe and improving the operator’s workflow. Functional imaging is also attainable using transverse oscillation and dedicated SA sequence for tensor velocity imaging for revealing the full 3-D velocity vector as a function of spatial position and time for both blood velocity and tissue motion estimation. Using RC arrays with commercial contrast agents can reveal super-resolution imaging (SRI) with isotropic resolution below $20~ \mu \text{m}$ . RC arrays can, thus, yield full 3-D imaging at high resolution, contrast, and volumetric rates for both anatomic and functional imaging with the same number of receive channels as current commercial 1-D arrays.

4 February 2022 in Ultrasonics
Verified
Journal Article
Open access
ITIman Taghavi
Iman Taghavi
SASofie Bech Andersen
Sofie Bech Andersen
CHCarlos Armando Villagómez Hoyos
Carlos Armando Villagómez Hoyos
MSMikkel Schou
Mikkel Schou
FGFredrik Gran
Fredrik Gran
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
Microbubble (MB) tracking plays an important role in ultrasound super-resolution imaging (SRI) by enabling velocity estimation and improving image quality. This work presents a new hierarchical Kalman (HK) tracker to achieve better performance at scenarios with high concentrations of MBs and high localization uncertainty. The method attempts to follow MBs with different velocity ranges using different Kalman filters. An extended simulation framework for evaluating trackers is also presented and used for comparison of the proposed HK tracker with the nearest-neighbor (NN) and Kalman (K) trackers. The HK tracks were most similar to the ground truth with the highest Jaccard similarity coefficient in 79% of the scenarios and the lowest root-mean-square error in 72% of the scenarios. The HK tracker reconstructed vessels with a more accurate diameter. In a scenario with an uncertainty of 51.2μm in MB localization, a vessel diameter of 250μm was estimated as 257μm by HK tracker, compared with 329μm and 389μm for the K and NN trackers. In the same scenario, the HK tracker estimated MB velocities with a relative bias down to 1.7% and a relative standard deviation down to 8.3%. Finally, the different tracking techniques were applied to in vivo data from rat kidneys, and trends similar to the simulations were observed. Conclusively, the results showed an improvement in tracking performance, when the HK tracker was employed in comparison with the NN and K trackers.

10 June 2024 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
MNMostafa Amin Naji
Mostafa Amin Naji
SPSebastian Kazmarek Præsius
Sebastian Kazmarek Præsius
ITIman Taghavi
Iman Taghavi
MSMikkel Schou
Mikkel Schou
ETErik Vilain Thomsen
Erik Vilain Thomsen
A new approach for vascular super resolution imaging using the erythrocytes as targets (SURE imaging) is described and investigated. SURE imaging does not require fragile contrast agent bubbles, making it possible to use the maximum allowable mechanical index for ultrasound scanning for an increased penetration depth. A synthetic aperture ultrasound sequence was employed with 12 virtual sources using a 10 MHz GE L8-18i-D linear array hockey stick probe. The axial resolution was 1.20λ,(185.0μm) and the lateral resolution was 1.50λ,(231.3μm). Field IIpro simulations were conducted on 12.5 μm radius vessel pairs with varying separations. A vessel pair with a separation of 70 μm could be resolved, indicating a SURE image resolution below half a wavelength. A Verasonics research scanner was used for the in vivo experiments to scan the kidneys of Sprague-Dawley rats for up to 46 s to visualize their microvasculature by processing from 0.1 up to 45 s of data for SURE imaging, and for 46.8 s for super resolution (SR) imaging with a SonoVue contrast agent. Afterward, the renal vasculature was filled with the ex vivo micro-CT contrast agent Microfil, excised, and scanned in a micro-CT scanner at both a 22.6 μm voxel size for 11 hours, and for 20 hours in a 5 μm voxel size for validating the SURE images. Comparing the SURE and micro-CT images revealed that vessels with a diameter of 28 μm, five times smaller than the ultrasound wavelength, could be detected, and the dense grid of microvessels in the full kidney was shown for scan times between 1 to 10 s. The vessel structure in the cortex was also similar for the SURE and SR images. Fourier ring correlation indicated a resolution capability of 29 μm. SURE images are acquired in seconds rather than minutes without any patient preparation or contrast injection, making the method translatable to clinical use.

10 June 2024 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
MNMostafa Amin Naji
Mostafa Amin Naji
ITIman Taghavi
Iman Taghavi
MSMikkel Schou
Mikkel Schou
SPSebastian Kazmarek Præsius
Sebastian Kazmarek Præsius
LHLauge Naur Hansen
Lauge Naur Hansen
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
Super resolution ultrasound imaging using the erythrocytes (SURE) has recently been introduced. The method uses erythrocytes as targets instead of fragile microbubbles (MBs). The abundance of erythrocyte scatterers makes it possible to acquire SURE data in just a few seconds compared to several minutes in ultrasound localization microscopy (ULM) using MBs. A high number of scatterers can reduce the acquisition time, however, the tracking of uncorrelated and high-density scatterers is quite challenging. This paper hypothesizes that it is possible to detect and track erythrocytes as targets to obtain vascular flow images. A SURE tracking pipeline is used with modules for beamforming, recursive synthetic aperture imaging, motion estimation, echo canceling, peak detection, and recursive nearest neighbor tracker. The SURE tracking pipeline is capable of distinguishing the flow direction and separating tubes of a simulated Field II phantom with 125 to 25 μm wall-to-wall tube distances, as well as a 3D-printed hydrogel micro-flow phantom with 100 to 60 μm wall-to-wall channel distances. The comparison of an in-vivo SURE scan of a Sprague-Dawley rat kidney with ULM and micro-CT scans with voxel sizes of 26.5μm and 5μm demonstrated consistent findings. A microvascular structure composed of 16 vessels exhibited similarities across all imaging modalities. The flow direction and velocity profiles in the SURE scan were found to be concordant with those from ULM.

8 April 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
MSMatthias Bo Stuart
Matthias Bo Stuart
PJPatrick Møller Jensen
Patrick Møller Jensen
JOJulian Thomas Reckeweg Olsen
Julian Thomas Reckeweg Olsen
AKAlexander Borch Kristensen
Alexander Borch Kristensen
MSMikkel Schou
Mikkel Schou
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
Two delay-and-sum beamformers for 3-D synthetic aperture imaging with row-column addressed arrays are presented. Both beamformers are software implementations for graphics processing unit (GPU) execution with dynamic apodizations and third-order polynomial subsample interpolation. The first beamformer was written in the MATLAB programming language and the second was written in C/C++ with the compute unified device architecture (CUDA) extensions by NVIDIA. Performance was measured as volume rate and sample throughput on three different GPUs: a 1050 Ti, a 1080 Ti, and a TITAN V. The beamformers were evaluated across 112 combinations of output geometry, depth range, transducer array size, number of virtual sources, floating-point precision, and Nyquist rate or in-phase/quadrature beamforming using analytic signals. Real-time imaging defined as more than 30 volumes per second was attained by the CUDA beamformer on the three GPUs for 13, 27, and 43 setups, respectively. The MATLAB beamformer did not attain real-time imaging for any setup. The median, single-precision sample throughput of the CUDA beamformer was 4.9, 20.8, and 33.5 Gsamples/s on the three GPUs, respectively. The throughput of CUDA beamformer was an order of magnitude higher than that of the MATLAB beamformer.

17 August 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MSMikkel Schou
Mikkel Schou
LJLasse Thurmann Jorgensen
Lasse Thurmann Jorgensen
CBChristopher Beers
Christopher Beers
MTMarie Sand Traberg
Marie Sand Traberg
BTBorislav Gueorguiev Tomov
Borislav Gueorguiev Tomov
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
This paper presents an imaging scheme capable of estimating the full 3-D velocity vector field in a volume using rowcolumn addressed (RCA) arrays at a high volume rate. A 62+62 RCA array is employed with an interleaved synthetic aperture sequence. It contains repeated emissions with rows and columns interleaved with B-mode emissions. The sequence contains 80 emissions in total and can provide continuous volumetric data at a volume rate above 125 Hz. A transverse oscillation crosscorrelation estimator determines all three velocity components. The approach is investigated using Field II simulations and measurements using a specially built 3 MHz 62+62 RCA array connected to the SARUS experimental scanner. Both the B-mode and flow sequences have a penetration depth of 14 cm when measured on a tissue mimicking phantom (0.5 dB/[MHz·cm] attenuation). Simulations of a parabolic flow in a 12 mm diameter vessel at a depth of 30 mm, beam-to-flow angle of 90°, and xyrotation of 45° gave a standard deviation (SD) of (3.3, 3.4, 0.4)% and bias of (-3.3, -3.9, -0.1)%, for (vx, vy, vz). Decreasing the beam-to-flow angle to 60° gave a SD of (8.9, 9.1, 0.8)% and bias of (-7.6, -9.5, -7.2)%, showing a slight increase. Measurements were carried out using a similar setup, and pulsing at 2 kHz yielded comparable results at 90° with a SD of (5.8, 5.5, 1.1)% and bias of (1.4, -6.4, 2.4)%. At 60° the SD was (5.2, 4.7 1.2)% and bias (-4.6, 6.9, -7.4)%. Results from measurements across all tested settings showed a maximum SD of 6.8% and a maximum bias of 15.8%, for a peak velocity of 10 cm/s. A tissue mimicking phantom with a straight vessel was used to introduce clutter, tissue motion, and a pulsating flow. The pulsating velocity magnitude was estimated across 10 pulse periods and yielded an SD of 10.9%. The method was capable of estimating transverse flow components precisely, but underestimated the flow with small beam-to-flow angles. The sequence provided continuous data in both time and space throughout the volume, allowing for retrospective analysis of the flow. Moreover, B-mode planes can be selected retrospectively anywhere in the volume. This shows that tensor velocity imaging (full 3-D volumetric vector flow imaging) can be estimated in 4-D (x,y,z,t) using only 62 channels in receive, making 4-D volumetric imaging implementable on current scanner hardware.