3 May 2023 in IEEE Sensors Journal
Complementary Gray code N step phase shift algorithm has been widely used because of its high detection accuracy. In order to solve its low detection efficiency and real-time detection, this paper proposes a grating projection profilometry based on the combination of complementary Gray code and Fourfold-N step phase shift algorithm. When the number of phase shift steps is an integral multiple of four, divide images into N/4 groups according to the same phase difference, then get the wrapped phase of each group images and fuse them. Finally, unwrap phase with complementary Gray code. The algorithm in this paper can quickly eliminate periodic phase error and obtain high-precision unwrapped phase. In order to prove the effectiveness of this algorithm, the algorithm in this paper is compared with the N step phase shift algorithm of complementary Gray code and the Double N step phase shift algorithm of complementary Gray code with different N-values. Experimental result shows that the proposed algorithm can achieve high-precision phase unwrapping and improve the efficiency by 5%-20%.
21 August 2023 in IEEE Photonics Journal
The complementary Gray code double N-step phase shift method is widely used because of its high detection accuracy and good robustness. However, phase unwrapping methods have the problem of low detection efficiency. In order to solve above problem, this paper proposes a complementary Gray code like double N-step phase shift method without Gray code fringe images. Firstly, the wrapped phases of the different groups of phase shift fringe images are obtained, then we get the phase difference and the fused wrapped phase, and the phase difference is converted into Gray code series. Finally, the unwrapped phase of the measured target is obtained by combining the fused wrapped phase and the Gray code series. This method in this paper improves the detection efficiency. To verify the effectiveness of method proposed in this paper, the method is compared with the complementary Gray code double N-step phase shift method, the complementary Gray code 2N-step phase shift method and the phase derivative variance method. The experimental results show that the method in this paper could effectively obtain the high-precision unwrapped phase, and the efficiency is 33.3% higher than the complementary Gray code double N-step phase shift method and the complementary Gray code 2N-step phase shift method.
4 March 2025 in Measurement Science and Technology
In fringe projection profilometry, a method for solving 3D information by combining Gray code fringe images with phase-shifting fringe images has been widely used. In practice, there may still be phase mismatch between wrapped phase and complementary Gray code arrays. Based on the above problems, this paper proposes an improved complementary Gray code combined with phase-shifting profilometry (PSP) based on phase adjustment. First, the projected images are calibrated in advance, that is, the initial phase (image order) of the phase-shifting fringe images are adjusted so that the wrapped phase and the Gray code arrays match each other, and this image order is called the best order. Then, in the following practical measurements, the phase-shifting fringe images are substituted into the phase-shifting equation in accordance with this best order to obtain the wrapped phase. Finally, phase unwrapping is performed using the complementary Gray code phase unwrapping method to obtain the final unwrapped phase and 3D information from the phase-height mapping method. Compared to the traditional complementary Gray code combined with PSP, the proposed method can effectively improve the measurement quality without adding new projection images. Experiments show that the proposed method can improve the root mean square error (RMSE) and mean absolute error (MAE) accuracy by 89.63% and 89.76%, respectively, compared with the traditional complementary Gray code combined with the phase-shifting method (which has phase mismatch at this time), which improves the RMSE and MAE accuracy by −10.11% and −8.53%, respectively, and improves the efficiency compared with multi-frequency temporal phase unwrapping.
6 March 2024 in IEEE Sensors Journal
Achieving high-precision 3D measurement of targets in complex environments always as the focus of research in the field of industrial measurement. In order to solve the problem that the unstable light source affects the accuracy of 3D measurement in many industrial scenes, this paper proposes an improved phase- shifting profilometry for non-constant light intensity environment. The mathematical mechanism model of the influence of average intensity and intensity modulation on detection accuracy is obtained by analyzing, and then an improved method is proposed according to the above mechanism model to eliminate the phase error and improve the accuracy. Experimental results show the proposed method could obtain high-precision measurement results for non-constant light intensity environment, and based on the root mean square error, the detection accuracy of the proposed method is improved 46.57% than CGC-NSPSM, EA-CGC-NSPSM and EP-CGC-NSPSM.
26 February 2026 in Physica Scripta
In order to improve the three-dimensional measurement efficiency by reducing the fringe images in the phase-shifting fringe projection profilometry and obtain high-quality unwrapped phase. An improved two-step phase-shifting profilometry combined with complementary Gray code phase unwrapping is proposed in this paper. The method firstly generates an average intensity image by collecting the redesigned Gray code fringe images, and then eliminates the average intensity in the two phase-shifting fringe images by this image, then the processed phase-shifting fringe images are substituted into the improved two-step phase-shifting profilometry proposed in this paper to effectively adjust the initial phase and get the adjusted wrapped phase. Finally, the wrapped phase is unwrapped by the complementary Gray code phase unwrapping method to get the high-quality unwrapped phase. Experimental results show that only two phase-shifting fringe images could obtain the wrapped phase and the proposed method has strong robustness. Compared with the complementary Gray code ’2+1’ phase-shifting profilometry, the detection efficiency are improved by 14.29%, Compared with the complementary Gray code two-step phase-shifting profilometry (using the phase-shifting profilometry to eliminate average intensity, the detection efficiency are improved by 25%.