Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2023 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
TATimur F. Akhmetzhanov
Timur F. Akhmetzhanov
TLTimur A. Labutin
Timur A. Labutin
DKDmitriy Korshunov
Dmitriy Korshunov
ASAlexey A. Samsonov
Alexey A. Samsonov
APAndrey M. Popov
Andrey M. Popov
In this study, we utilized a handheld LIBS (laser-induced breakdown spectroscopy) analyzer (Z-300, SciAps) to quantitatively determine cerium and lanthanum in ores enriched with rare earth elements (REEs). Due to the complex electronic structure of REEs and their presence in laser plasma in multiple ionization stages (neutral, singly- and doubly-ionized species), determining their concentrations using a handheld instrument with relatively low spectral resolution is a challenging task for on-field quantitative analysis. Another issue is the rich emission spectrum of matrix elements of ores, which can cause strong overlapping between lines of analytes and matrixes, preventing quantitative analysis of ores. To address this issue, we employed Design of Experiment based on Latin Hypercube Sampling to construct an artificial calibration set of samples with varying REEs content. We compared univariate calibration and projection to latent structures (PLS) regression for atomic and ionic lines of REEs, as well as for molecular bands of LaO (740.5 nm). We observed a worsening of calibration due to matrix effects for LaO molecules. To validate our method, we used certified reference material of OREAS natural ore samples to simulate the real in-field application of the handheld analyzer. Our study revealed that Ce can be quantified regardless of concentration in niobium REE-rich ores with a relative error of about ±10% if the Ce II line at 462.82 nm is used, which is close to the level of quantitative accuracy. However, predicted concentrations of La in OREAS 460–465 appear to be biased by matrix effects. We conclude that the accuracy achieved in our study is mostly sufficient for qualitative analysis of uranium ores (OREAS 100a–102a). Furthermore, considering the possible matrix effects in La determination, we suggest that it is possible to use OREAS samples as a calibration set instead of artificial samples to build linear univariate regression models, as the lines employed in this study do not overlap. Our results are expected to optimize the procedure of online in-field monitoring of the mining process and provide rapid preliminary analysis for decision-making, with further, more time-consuming, and accurate analysis (e.g., using ICP-OES/MS) required as necessary.

13 November 2023 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
TATimur F. Akhmetzhanov
Timur F. Akhmetzhanov
TCTatiana Cherkashina
Tatiana Cherkashina
AZAlena N. Zhilicheva
Alena N. Zhilicheva
VCVictor M Chubarov
Victor M Chubarov
GPGalina V. Pashkova
Galina V. Pashkova
The insufficient spectral resolution of the energy-dispersive total-reflection X-ray fluorescence (TXRF) complicates the U and Th Lα lines using for the quantitative determination of low concentrations of these elements in natural solid samples.

25 July 2025 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
TATimur F. Akhmetzhanov
Timur F. Akhmetzhanov
AAAlexandra Alexandrovna Arkhipenko
Alexandra Alexandrovna Arkhipenko
MRMikhail A. Ryumin
Mikhail A. Ryumin
IYIlya Yakushev
Ilya Yakushev
MDMarina S. Doronina
Marina S. Doronina
VBVasilisa B. Baranovskaya
Vasilisa B. Baranovskaya
In this paper, we discuss strategies for analysing medium- and high-entropy ceramics (REE3NbO7) that contain 4 and 5 different rare-earth elements. In the coming years, it may be necessary to shift from laboratory-based analysis of ceramic powders to on-site examination of thermal barrier coatings, particularly those employed in aircraft engines. To address this, we employed a portable X-ray fluorescence spectrometer capable of in-field non-destructive simultaneous quantification of Gd, Er, Tm, Yb and Y. The major problem with portable systems is the overlap of Gd, Er, Tm, and Yb lines. Therefore, we conducted a complete comparative study of the strategies that allow for the acquisition of analytical signals in the energy-dispersive spectra. In order to critically evaluate the need for deconvolution, a technique often suggested in the literature, we used wavelength-dispersive X-ray fluorescence. This XRF variant was used to obtain spectra with higher resolution, and thus different levels of line overlap. In this work, we highlighted peculiarities of the deconvolution process in higher- and lower-resolution X-ray fluorescence spectra. The study revealed that the portable spectrometer is capable of accurately quantifying the concentrations of Gd, Er, Tm, Yb, and Y in both medium- and high-entropy ceramics. A comparative analysis showed that quantitative analysis of medium- and high-entropy ceramics does not require deconvolution of energy-dispersive spectra. It is shown that the samples synthesised using the reverse precipitation method allow one to obtain reliable calibration curves and avoid matrix effects using a portable X-ray fluorescence spectrometer, despite the fact that the concentrations of the major components vary 3 times. However, it was found that experimental conditions in a vacuumed wavelength-dispersive X-ray fluorescence spectrometer reduced trueness by approx. 9%. Nevertheless, this system proved to be a suitable substitute for ICP-OES in laboratory practices. The portable version, on the other hand, holds promise for in-field use.