Jesús Pérez-Gracia

Jesús Pérez-Gracia

Auto-generated profile, based on publicly available information

Jesús Pérez-Gracia

Universidad de Zaragoza

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JPJesús Pérez-Gracia
Jesús Pérez-Gracia
AVAlejandra Varea
Alejandra Varea
JAJorge Ares
Jorge Ares
JVJuan A. Vallés
Juan A. Vallés
LRLaura Remón
Laura Remón
To evaluate and compare the effect of misalignment and tilt on the optical performance of different aspheric intraocular lens (IOL) designs. Three aspheric IOLs with a different quantity of spherical aberration (SA) have been designed and the effect of IOL misalignment and tilt on the imaging quality of an eye model has been numerically assessed using a commercial optical design software. The prototypes have been manufactured by lathe turning and tested in vitro using the same optical bench (PMTF, Lambda-X) that complies with International Organization for Standardization standard 11979–2 requirements. Image quality was evaluated from the modulation transfer functions (MTFs), through-focus modulation transfer functions (TF-MTFs), root mean square (RMS) values of defocus, astigmatism and coma, and images of the United States Air Force (USAF) target were taken. A comparison with the optical performance of spherical IOLs has also been performed. Intraocular lens misalignment and tilt increased wavefront aberrations; the effect of misalignment on root mean square (RMS) astigmatism and coma was positively correlated with the spherical aberration of the IOL. Aberration-free IOLs showed the highest MTF for all misalignment values and for IOLs with negative SA correction the MTF decays below 0.43 when they are decentered 0.50 mm. Aspherical IOLs are more sensitive than spherical IOLs to misalignment or tilt, depending on their SA correction. The optical degradation caused by IOL misalignment had a greater effect on IOL designs with a higher amount of negative spherical aberration. In contrast, the effect of tilt on the optical performance was less sensitive to the IOL design.

14 December 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JPJesús Pérez-Gracia
Jesús Pérez-Gracia
FÁFrancisco J. Ávila
Francisco J. Ávila
JAJorge Ares
Jorge Ares
JVJuan A. Vallés
Juan A. Vallés
LRLaura Remón
Laura Remón
Purpose: To numerically evaluate and compare the tolerance to misalignment and tilt of aspheric intraocular lenses (IOLs) designed for three eyes: with standard cornea and with simulated corneas after myopic and hyperopic laser ablation surgery. Methods: Three aspheric IOLs of +20.00 diopter (D) with different spherical aberration (SA) ( Z40 ) values have been designed using a theoretical model eye. Drastic changes on the theoretical eye anterior corneal asphericity have been performed to simulate myopic and hyperopic refractive surgeries. The effect of IOL misalignment and tilt on the image quality has been evaluated using a commercial optical software design for the three eye models. Image quality was assessed from the modulation transfer function (MTF), root mean square (RMS) values of defocus, astigmatism, coma and spherical aberration ( Z40 ), and retinal images obtained from a visual simulator using an aleatory optotype of 0.00 LogMar visual acuity (VA). Results: IOL misalignment and tilt reduced MTF values in general, and increased wavefront aberrations errors. Aberration-free IOLs maintained best the MTF values when misalignments were applied, together with good on-axis optical quality. IOLs with negative SA ( Z40 ) correction decreased the MTF value under 0.43 for misalignments values higher than 0.50 mm with the three corneas. The effect of misalignment on RMS astigmatism and coma was correlated with the IOL SA ( Z40 ) and with the three corneas. Conclusions: This theoretical study shows that the largest degradation in image quality arises for the IOL with the highest amount of spherical aberration ( Z40 ). Moreover, it has been found that the aspherical design has a more influential role in misalignment tolerance than in tilt tolerance.

8 March 2022 in Biomedical Optics Express
Verified
Journal Article
Closed access
JPJesús Pérez-Gracia
Jesús Pérez-Gracia
JAJorge Ares
Jorge Ares
Francisco Avila GomezFrancisco Avila Gomez
Francisco Avila Gomez
LRLaura Remón
Laura Remón
Toric intraocular lenses (T-IOLs) may lose their optical quality if they are not correctly positioned inside the capsular bag once implanted. In this work, T-IOLs with cylinder powers of +1.50, +4.50 and +7.50 D and differing degrees of spherical aberration have been designed, manufactured and tested in vitro using a commercial optical bench that complies with the requirements of standard ISO 11979-2. Moreover, the effect of tilt and rotation on optical quality was assessed by means of numerical ray tracing on an astigmatic eye model, while the effect of decentration was evaluated numerically and experimentally.

30 January 2023 in Ophthalmic Research
Verified
Journal Article
Open access
PDF file
MLMarta Lacort
Marta Lacort
JPJesús Pérez-Gracia
Jesús Pérez-Gracia
JAJorge Ares
Jorge Ares
LRLaura Remón
Laura Remón
Introduction: Intraocular lenses (IOLs) may lose their optical quality if they are not correctly placed inside the capsular bag once implanted. One possible malpositioning of the IOL could be the implantation in an upside-down position. In this work, three aspheric IOLs with different spherical aberration (SA) have been designed and numerically tested to analyse the optical quality variation with the IOL flip, and misalignments, using a theoretical model eye. Methods: Using the commercial optical design software OSLO, the effect of decentration and tilt was evaluated by numerical ray tracing in two conditions: in their designed position and flipped with respect to the planned position (IOL is implanted upside down). The theoretical model eye used was the Atchison model eye. Seven IOL designs of +27.00 diopters were used: a lens with negative SA to correct the corneal SA, a lens to partially correct the corneal SA, and a lens to not add any SA to the cornea (aberration-free IOL). These lenses were designed with the aspherical surface located on the anterior and posterior IOL surface. A lens with no aspherical surfaces was also included. For the optical quality analysis, the modulation transfer function (MTF) was used, together with the Zernike wavefront aberration coefficients of defocus, astigmatism, and primary coma. Results: Off-centring and tilting the IOL reduced overall MTF values and increased wavefront aberration errors. With the IOL correctly positioned within the capsular bag, an aberration-free IOL is the best choice for maintaining optical quality. When the IOL is flipped inside the capsular bag, the optical quality changes, with the aberration-free IOL and the IOL without aspheric surfaces providing the worst results. With the lens in an upside-down position, an IOL design to partially correct corneal SA shows the best optical quality results in decentration and tilt, in terms of MTF and wavefront aberrations. Conclusion: The aberration-free IOL is the best choice when minimal postoperative errors of decentration or tilt are predicted. With IOL flip, the negative SA lens design is the best choice, regarding the root mean square wavefront aberrations. However, in a proper IOL implantation, the IOL designed to partially compensate the corneal SA including asphericity on its posterior surface is the better possible option, even in the presence of decentration or tilt.