Laura Remón

Dr. Laura Remón

Departamento de Física Aplicada, Facultad de Ciencias, Universidad de Zaragoza, 50009 Zaragoza, Spain
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
LRLaura Remón
Laura Remón
Pablo Pérez-MerinoPablo Pérez-Merino
Pablo Pérez-Merino
RMRute J. Macedo-De-Araújo
Rute J. Macedo-De-Araújo
Ana Amorim-de-SousaAna Amorim-de-Sousa
Ana Amorim-de-Sousa
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome
Bifocal and multifocal optical devices are intended to get images into focus from objects placed at different distances from the observer. Spectacles, contact lenses, and intraocular lenses can meet the requirements to provide such a solution. Contact lenses provide unique characteristics as a platform for implementing bifocality and multifocality. Compared to spectacles, they are closer to the eye, providing a wider field of view, less distortion, and their use is more consistent as they are not so easily removed along the day. In addition, contact lenses are also minimally invasive, can be easily exchangeable, and, therefore, suitable for conditions in which surgical procedures are not indicated. Contact lenses can remain centered with the eye despite eye movements, providing the possibility for simultaneous imaging from different object distances. The main current indications for bifocal and multifocal contact lenses include presbyopia correction in adult population and myopia control in children. Considering the large numbers of potential candidates for optical correction of presbyopia and the demographic trends in myopia, the potential impact of contact lenses for presbyopia and myopia applications is undoubtedly tremendous. However, the ocular characteristics and expectations vary significantly between young and older candidates and impose different challenges in fitting bifocal and multifocal contact lenses for the correction of presbyopia and myopia control. This review presents the recent developments in material platforms, optical designs, simulated visual performance, and the clinical performance assessment of bifocal and multifocal contact lenses for presbyopia correction and/or myopia progression control.

4 May 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JPJesús Pérez-Gracia
Jesús Pérez-Gracia
AVAlejandra Varea
Alejandra Varea
JAJorge Ares
Jorge Ares
JVJuan A. Vallés
Juan A. Vallés
LRLaura Remón
Laura Remón
To evaluate and compare the effect of misalignment and tilt on the optical performance of different aspheric intraocular lens (IOL) designs. Three aspheric IOLs with a different quantity of spherical aberration (SA) have been designed and the effect of IOL misalignment and tilt on the imaging quality of an eye model has been numerically assessed using a commercial optical design software. The prototypes have been manufactured by lathe turning and tested in vitro using the same optical bench (PMTF, Lambda-X) that complies with International Organization for Standardization standard 11979–2 requirements. Image quality was evaluated from the modulation transfer functions (MTFs), through-focus modulation transfer functions (TF-MTFs), root mean square (RMS) values of defocus, astigmatism and coma, and images of the United States Air Force (USAF) target were taken. A comparison with the optical performance of spherical IOLs has also been performed. Intraocular lens misalignment and tilt increased wavefront aberrations; the effect of misalignment on root mean square (RMS) astigmatism and coma was positively correlated with the spherical aberration of the IOL. Aberration-free IOLs showed the highest MTF for all misalignment values and for IOLs with negative SA correction the MTF decays below 0.43 when they are decentered 0.50 mm. Aspherical IOLs are more sensitive than spherical IOLs to misalignment or tilt, depending on their SA correction. The optical degradation caused by IOL misalignment had a greater effect on IOL designs with a higher amount of negative spherical aberration. In contrast, the effect of tilt on the optical performance was less sensitive to the IOL design.

21 November 2022 in Ophthalmic and Physiological Optics
Verified
Journal Article
Open access
ACAlejandra Consejo
Alejandra Consejo
ITIrene Trillo‐Moreno
Irene Trillo‐Moreno
LRLaura Remón
Laura Remón
Purpose: To study the effect of different soft contact lens (CL) materials during short‐term wear on corneal tissue. Methods: Twenty‐two healthy participants wore both silicone hydrogel (MyDay, CooperVision) and hydrogel soft CLs (Biomedics 1 day extra, CooperVision) for 8 h per lens. In each session, Scheimpflug images were captured before and immediately after CL removal. Images were analysed using the densitometry distribution analysis, a technique from which two parameters, α (corneal transparency) and β (corneal homogeneity), were estimated. In addition, the central corneal thickness changes after CL wear and the influence of the CL material on corneal transparency were evaluated. Results: The β parameter (homogeneity) increased by 5% after wearing both CL materials (paired t ‐test, p < 0.001). However, the α parameter (transparency) only increased in half of the participants. No material was found to be more determinant in causing the corneal densitometry changes. Statistically significant but not clinically relevant changes in corneal thickness were observed. Conclusions: Biomarkers of corneal tissue integrity ( α and β ) were affected by short‐term soft contact lens wear. The observed changes in corneal transparency and homogeneity were not clinically relevant but support the importance of participant‐material biocompatibility.

14 December 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JPJesús Pérez-Gracia
Jesús Pérez-Gracia
FÁFrancisco J. Ávila
Francisco J. Ávila
JAJorge Ares
Jorge Ares
JVJuan A. Vallés
Juan A. Vallés
LRLaura Remón
Laura Remón
Purpose: To numerically evaluate and compare the tolerance to misalignment and tilt of aspheric intraocular lenses (IOLs) designed for three eyes: with standard cornea and with simulated corneas after myopic and hyperopic laser ablation surgery. Methods: Three aspheric IOLs of +20.00 diopter (D) with different spherical aberration (SA) ( Z40 ) values have been designed using a theoretical model eye. Drastic changes on the theoretical eye anterior corneal asphericity have been performed to simulate myopic and hyperopic refractive surgeries. The effect of IOL misalignment and tilt on the image quality has been evaluated using a commercial optical software design for the three eye models. Image quality was assessed from the modulation transfer function (MTF), root mean square (RMS) values of defocus, astigmatism, coma and spherical aberration ( Z40 ), and retinal images obtained from a visual simulator using an aleatory optotype of 0.00 LogMar visual acuity (VA). Results: IOL misalignment and tilt reduced MTF values in general, and increased wavefront aberrations errors. Aberration-free IOLs maintained best the MTF values when misalignments were applied, together with good on-axis optical quality. IOLs with negative SA ( Z40 ) correction decreased the MTF value under 0.43 for misalignments values higher than 0.50 mm with the three corneas. The effect of misalignment on RMS astigmatism and coma was correlated with the IOL SA ( Z40 ) and with the three corneas. Conclusions: This theoretical study shows that the largest degradation in image quality arises for the IOL with the highest amount of spherical aberration ( Z40 ). Moreover, it has been found that the aspherical design has a more influential role in misalignment tolerance than in tilt tolerance.

18 December 2021 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Francisco Avila GomezFrancisco Avila Gomez
Francisco Avila Gomez
CMConcepción Vidosa Marcellán
Concepción Vidosa Marcellán
LRLaura Remón
Laura Remón
Optical properties of the cornea are responsible for correct vision; the ultrastructure allows optical transparency, and the biomechanical properties govern the shape, elasticity, or stiffness of the cornea, affecting ocular integrity and intraocular pressure. Therefore, the optical aberrations, corneal transparency, structure, and biomechanics play a fundamental role in the optical quality of human vision, ocular health, and refractive surgery outcomes. However, the inter-relationships of those properties are not yet reported at a macroscopic scale within the hierarchical structure of the cornea. This work explores the relationships between the biomechanics, structure, and optical properties (corneal aberrations and optical density) at a macro-structural level of the cornea through dual Placido–Scheimpflug imaging and air-puff tonometry systems in a healthy young adult population. Results showed correlation between optical transparency, corneal macrostructure, and biomechanics, whereas corneal aberrations and in particular spherical terms remained independent. A compensation mechanism for the spherical aberration is proposed through corneal shape and biomechanics.

8 March 2022 in Biomedical Optics Express
Verified
Journal Article
Closed access
JPJesús Pérez-Gracia
Jesús Pérez-Gracia
JAJorge Ares
Jorge Ares
Francisco Avila GomezFrancisco Avila Gomez
Francisco Avila Gomez
LRLaura Remón
Laura Remón
Toric intraocular lenses (T-IOLs) may lose their optical quality if they are not correctly positioned inside the capsular bag once implanted. In this work, T-IOLs with cylinder powers of +1.50, +4.50 and +7.50 D and differing degrees of spherical aberration have been designed, manufactured and tested in vitro using a commercial optical bench that complies with the requirements of standard ISO 11979-2. Moreover, the effect of tilt and rotation on optical quality was assessed by means of numerical ray tracing on an astigmatic eye model, while the effect of decentration was evaluated numerically and experimentally.