Johannes Schlarp

Johannes Schlarp

Auto-generated profile, based on publicly available information

Johannes Schlarp

Christian Doppler Laboratory for Precision Engineering for Automated In-Line Metrology, Automation and Control Institute (ACIN), Vienna University of Technology, Vienna, Austria

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2018 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
ECErnst Csencsics
Ernst Csencsics
JSJohannes Schlarp
Johannes Schlarp
GSGeorg Schitter
Georg Schitter
This paper presents the design, assembly, and evaluation of a novel integrated two degree of freedom (2DoF) actuator design for tip/tilt motion and its integration into a fast steering mirror with comparably large range. The system is designed for scanning applications, such as in optical metrology systems, and comprises an integrated symmetric 2DoF hybrid-reluctance-force actuator and mover-flexure-design. The actuator design employs a permanent magnet for biasing the actuator with a constant flux and two actuator coils per axis to generate a steering flux for positioning the mover. The system prototype has an angular range of $\pm 3^\circ$ in tip and tilt and achieves a closed-loop control bandwidth of 1 kHz based on the signal of eddy current sensors. Compared to the only so far realized state-of-the-art reluctance force actuated fast steering mirror system with integrated sensors, the presented design enables to improve the product of range times’ bandwidth, representing a measure for the system performance, by more than 85%.

20 June 2018 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JSJohannes Schlarp
Johannes Schlarp
ECErnst Csencsics
Ernst Csencsics
GSGeorg Schitter
Georg Schitter
In scanning laser triangulation sensors for 3D imaging, the achievable throughput is strongly limited by the moving mass. By realizing an optical scanning approach rather than repositioning the entire sensor, this limitation could be reduced, leading to a reduced measurement time. This work presents sensor system geometries in which only the optical path of a line triangulation sensor is manipulated by a tip-tilt mirror. In the proposed rotational scanning systems, either the illumination path or both the illumination and the reflection path are manipulated. By using ray-tracing simulation, the performance of the scanning systems are optimized and possible disadvantages can be determined up front. Using geometric relations, the surface profile can be reconstructed from the measured sensor data, the mirror position, and the model parameters. Experimental results show that the image quality of the proposed rotational scanning systems is comparable to systems based on classical translational scanning motion.

25 March 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SIShingo Ito
Shingo Ito
MPMathias Poik
Mathias Poik
JSJohannes Schlarp
Johannes Schlarp
GSGeorg Schitter
Georg Schitter
This paper proposes a mechatronic system design for atomic force microscopes (AFMs) in order to realize a large range and high control bandwidth of the vertical probe motion by a flexure-guided voice coil actuator. The first mechanical resonant frequency of the actuator is decreased to 67Hz for a large motion while the second resonant frequency is maximized to 1.15kHz. The frequency band between the resonances enables two-degree-of-freedom control with a position sensor to realize a control bandwidth of 881Hz, which is 13 times higher than the first resonance that is the limitation of conventional AFMs. The closed-loop actuator achieves a positioning resolution of 1.7nm and a nonlinearity of 0.02% for a motion range of 700μm. Consequently, the actuator realizes a range-bandwidth product of 617kHzμm, breaking through a theoretical limit of piezoelectric actuators (567kHzμm). The high performance of the actuator is further confirmed by 400μm topography measurement in the constant force mode with a bandwidth of 197Hz. The achieved resolution of the topography measurement is 2.9nm, and it is demonstrated by successfully imaging nanostructures on a CD-ROM disk.

9 October 2020 in Applied Optics
Verified
Journal Article
Closed access
SIShingo Ito
Shingo Ito
MPMathias Poik
Mathias Poik
ECErnst Csencsics
Ernst Csencsics
JSJohannes Schlarp
Johannes Schlarp
GSGeorg Schitter
Georg Schitter
This paper presents a scanning system that integrates a chromatic confocal displacement sensor for topography measurement of a surface. To take an advantage of its compactness and reliability, an off-the-shelf chromatic confocal displacement sensor is integrated. Instead of moving the sensor, a galvanometer scanner reflects the optical point to increase the scan speed, and fast and accurate scanning motion is realized by learning without a model. The resulting images are corrected based on a geometric model to compensate for image distortion.

19 December 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ECErnst Csencsics
Ernst Csencsics
JSJohannes Schlarp
Johannes Schlarp
TGTobias Glaser
Tobias Glaser
TWTobias Wolf
Tobias Wolf
GSGeorg Schitter
Georg Schitter
Laser triangulation sensors are one of the most commonly used optical sensors in dimensional metrology and quality control. This article presents a method for simulating the laser speckle-induced measurement uncertainty, representing a major performance limitation of these sensors, as well as the effects of speckle reduction mechanisms based on spatio-temporal averaging. To investigate the relation between triangulation angle and the resulting speckle-induced uncertainty, simulations are performed for three sensor geometries, revealing that a larger angle results not only in a smaller measurement range but also in a reduced influence of laser speckle and a smaller uncertainty. A parameter study on a speckle-reducing moving diffuser mechanism, integrated into the optical sensor path, investigates the achievable improvement for various combinations of motion frequency and amplitude. The accuracy of the simulation results is validated by measurements conducted with an experimental setup, demonstrating good agreement between the measured and simulated uncertainty values with and without the speckle reduction mechanism. It is shown that the diffuser is capable of reducing the resulting speckle-induced measurement uncertainty by up to 63%.

1 August 2018 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
JSJohannes Schlarp
Johannes Schlarp
ECErnst Csencsics
Ernst Csencsics
GSGeorg Schitter
Georg Schitter
Satisfying the Scheimpflug condition in a rotational scanning 3D triangulation sensor system can be challenging. By violating this condition an reproducible measurement error is generated, which is caused by the out of focus projected laser point on the detector. In this work a ray-tracing simulation of the scanning system is performed, in order to determine potential aberrations. With the reference measurement of a flat surface the error due to violation of the Scheimpflug condition is obtained. The error is systematic and reproducible and can be compensated by a correction polynomial, with coefficients determined by using the least squares method. Experimental results reveal, that the measurement error can be significantly reduced by the correction polynomial.