Shijie Cheng

Shijie Cheng

Auto-generated profile, based on publicly available information

Shijie Cheng

State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2018 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
JLJingang Lai
Jingang Lai
XLXiaoqing Lu
Xiaoqing Lu
XYXinghuo Yu
Xinghuo Yu
Wei YaoWei Yao
Wei Yao
JWJinyu Wen
Jinyu Wen
SCShijie Cheng
Shijie Cheng
This paper develops a novel distributed iterative event-triggered control scheme for a master-slave-organized dc microgrid network with limited communication bandwidth. The proposed algorithms in this paper can synchronize the voltage of multiple distributed energy resources (DER) to theirs desired value and achieve the optimal load sharing for their economic operation (e.g., minimize the total generation cost) through a low bandwidth communication network. The proposed iterative event-triggered control scheme is fully distributed and only driven at their own event time, which effectively reduces the frequency of controller updates compared with continuous-time feedback control. Eventually, each DER only requires the local voltage and current measurement from its own and some nearest neighbors (but not all) for the distributed control at given event-triggered time by using limited-bandwidth communication links. The Lyapunov technique is employed to devise the stability and convergence analysis of the proposed event-triggered conditions. Furthermore, the positive lower bound of the inter-even intervals is captured to exclude Zeno behaviors. Different cases in MATLAB/SimPowerSystems are investigated and results demonstrate the effectiveness and performance of the proposed approach.

24 September 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
XPXiaotao Peng
Xiaotao Peng
Wei YaoWei Yao
Wei Yao
CYCai Yan
Cai Yan
JWJinyu Wen
Jinyu Wen
SCShijie Cheng
Shijie Cheng
This paper proposes a variable proportion coefficient based control scheme for the doubly-fed induction generator based wind turbines (DFIG-WTs) to implement frequency support by regulating rotor speed. To reduce the adverse impact caused by regulating DFIG-WT on the dynamic characteristic of the grid frequency, a two-stage switching control scheme is employed for the proposed method. In the first stage, the variable proportion coefficient is designed for emulating the virtual inertia of the DFIG-WT to provide inertia response. In the second stage, a fuzzy control scheme is employed to design the variable proportion coefficient for both quickly restoring the maximum power point tracking (MPPT) operation of DFIG-WTs and avoiding the secondary frequency dip to system. Case studies are undertaken based on WSCC 9-bus and IEEE 39-bus power systems, respectively. Simulation results show that the proposed control scheme can not only make grid-connected DFIG-WTs provide the friendly frequency support, but also help them to fully use the frequency regulation ability of synchronous generators for quickly restoring the MPPT operation.

27 June 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Wei YaoWei Yao
Wei Yao
CLChang Liu
Chang Liu
Jiakun FangJiakun Fang
Jiakun Fang
XAXiaomeng Ai
Xiaomeng Ai
JWJinyu Wen
Jinyu Wen
SCShi-Jie Cheng
Shi-Jie Cheng
This paper investigates the in-depth mechanism of commutation failure for a line-commuted converter based high voltage direct current (LCC-HVDC) system. The commutation failure prevention control (CFPREV) and the initial fault voltage angle (IFVA) are considered from the view of the voltage-time area (VTA) in the analysis. It is revealed that the IFVA is among the dominant factors for commutation failures when the voltage drop of the inverter bus is relatively small, and CFPREV further intensifies the impact of the IFVA on commutation failures, while the fluctuation of the direct current plays a dominant role in commutation failures under a greater voltage reduction at the inverter bus. A quantitative division of the severity of AC faults is proposed to determine dominant factors for commutation failures. The relationship between the chance of commutation failures to occur and the IFVA is built, and the method used for computing probability of commutation failures is proposed. Simulations based on a typical monopole LCC-HVDC system using PSCAD/EMTDC software are conducted to verify the correctness of the theoretic analysis and the effectiveness of the proposed computing methods.

18 September 2020 in IEEE Systems Journal
Verified
Journal Article
Closed access
YZYifan Zhao
Yifan Zhao
Wei YaoWei Yao
Wei Yao
JNJiajun Nan
Jiajun Nan
Jiakun FangJiakun Fang
Jiakun Fang
XAXiaomeng Ai
Xiaomeng Ai
SCShijie Cheng
Shijie Cheng
The wide-area damping controller (WADC) using the remote signals obtained from wide-area measurement system (WAMS) as input is an effective measure to suppress interarea oscillations. Once the input signal of WADC is threatened by false data injection attacks (FDIAs), its performance will be decreased dramatically. To address this problem, this article proposes a resilient adaptive wide-area damping control (RAWADC) framework combined with linear state estimator (LSE) and goal representation heuristic dynamic programming (GrHDP). The LSE is proposed and adopted as a preprocessor to detect and correct the attacked data. By detecting and correcting FDIA, the integrity of the WAMS measurement signal is guaranteed. The GrHDP algorithm is employed to design the WADC, which not only does not require a detailed mathematical model of the system but can also adapt to variations of the operating conditions. Simulation results of the 16-machine 68-bus system with voltage source converter based HVdc indicate that the RAWADC can suppress interarea oscillation effectively under a wide range of operating conditions, different FDIA types and measurement noise.

3 August 2023 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
HZHong-yu Zhou
Hong-yu Zhou
Wei YaoWei Yao
Wei Yao
KSKangyi Sun
Kangyi Sun
XAXiaomeng Ai
Xiaomeng Ai
JWJinyu Wen
Jinyu Wen
SCShijie Cheng
Shijie Cheng
Onshore AC faults may cause the modular multilevel converter based high voltage direct current integrated offshore wind farms (MMC-HVDC-OWF) to develop surplus power and trigger overvoltage problems. This paper proposes a dynamic reactive current optimization (DRO) strategy that combines MMC energy control capability with transient overload capability to achieve onshore AC fault ride-through (ACFRT). Firstly, the decoupling control mechanism and constraints of the active and reactive currents of the onshore gird-side MMC (GSMMC) are analyzed. Furthermore, a dynamic reactive current optimization based ACFRT strategy is proposed based on the current constraints and the energy control capability of MMCs. The main parameters of DRO are set according to the fault characteristic analysis results. Once a fault occurs, the proposed DRO based ACFRT strategy can control the offshore surplus power by controlling the MMC internal sub-module energy. The DRO strategy quickly optimizes the active and reactive power output commands of the GSMMC by collecting and comparing the local power signals. It enables to increase the onshore AC grid voltage and the transient active power output of the MMC-HVDC-OWF. Finally, The effectiveness of the proposed control strategy is verified through comprehensive case studies conducted on the PSCAD/EMTDC.

25 January 2023 in IEEE Transactions on Neural Networks and Learning Systems
Verified
Journal Article
Closed access
ZSZhongtuo Shi
Zhongtuo Shi
Wei YaoWei Yao
Wei Yao
YTYong Tang
Yong Tang
XAXiaomeng Ai
Xiaomeng Ai
JWJinyu Wen
Jinyu Wen
SCShijie Cheng
Shijie Cheng
Simulation analysis is critical for identifying possible hazards and ensuring secure operation of power systems. In practice, large-disturbance rotor angle stability and voltage stability are two frequently intertwined stability problems. Accurately identifying the dominant instability mode (DIM) between them is important for directing power system emergency control action formulation. However, DIM identification has always relied on human expertise. This article proposes an intelligent DIM identification framework that can discriminate among stable status, rotor angle instability, and voltage instability based on active deep learning (ADL). To reduce human expert efforts required to label the DIM dataset when building DL models, a two-stage batch-mode integrated ADL query strategy (preselection and clustering) is designed for the framework. It samples only the most helpful samples to label in each iteration and considers both information contents and diversity in them to improve query efficiency, significantly reducing the required number of labeled samples. Case studies conducted on a benchmark power system (China Electric Power Research Institute (CEPRI) 36-bus system) and a practical large-area power system (Northeast China Power System) reveal that the proposed approach outperforms conventional methods in terms of accuracy, label efficiency, scalability, and adaptability to operational variability.