Meishan Liu

Meishan Liu

Auto-generated profile, based on publicly available information

Meishan Liu

Department of Respiratory and Critical Care Medicine, Beijing Institute of Respiratory Medicine and Beijing Chao-Yang Hospital, Capital Medical University, Beijing, People’s Republic of China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2023 in COPD: Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
MLMeishan Liu
Meishan Liu
YLYuna Li
Yuna Li
DYDanfeng Yin
Danfeng Yin
YWYing Wang
Ying Wang
TFTingting Fu
Tingting Fu
KHKewu Huang
Kewu Huang
Anxiety and depression are common comorbidities in chronic obstructive pulmonary disease (COPD) patients but are often under-diagnosed. We aimed to assess the suitability of the COPD Assessment Test (CAT) in screening anxiety and depression in patients with COPD. Stable COPD patients from a cross-sectional observational study were assessed by CAT. Anxiety and depression were identified using the Generalized Anxiety Disorder questionnaire (GAD-7) and Patient Health Questionnaire (PHQ-9), respectively. Logistic regression analysis and receiver operating characteristic curve analysis were used to identify factors associated with anxiety or depression and to calculate the predictive values. A total of 530 stable COPD patients were enrolled and of those, the proportions of anxiety and depression were 17.0% and 21.5%, respectively. The adjusted odds ratios of the CAT for the presence of anxiety and depression were 1.094 (95%CI: 1.057–1.131) and 1.143 (95%CI: 1.104–1.183), respectively. The CAT score had a significant predictive value for the presence of anxiety (AUC = 0.709) and depression (AUC = 0.791) with an optimum cutoff score of 15. However, the psychometric properties of CAT were undesirable, presenting high negative predictive value (NPV) but low positive predictive value (PPV). Among CAT items, analysis further showed that non-respiratory CAT components were superior to respiratory components in identifying both anxiety and depression. Our results indicated that CAT is more useful to exclude anxiety and depression rather than detect them.

1 April 2023 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
MLMeishan Liu
Meishan Liu
DYDanfeng Yin
Danfeng Yin
YWYing Wang
Ying Wang
WWWenjun Wang
Wenjun Wang
TFTingting Fu
Tingting Fu
KHKewu Huang
Kewu Huang
Purpose: Screening questionnaires can help identify individuals at a high risk of COPD. This study aimed to compare the performance of the COPD population screener (COPD-PS) and COPD screening questionnaire (COPD-SQ) on the general population as a full cohort and stratified by urbanization. Methods: We recruited subjects who underwent a health checkup at urban and rural community health centers in Beijing. All eligible subjects completed the COPD-PS and COPD-SQ, then spirometry. Spirometry-defined COPD was defined as a post-bronchodilator FEV1/FVC< 70%. Symptomatic COPD was defined as a post-bronchodilator FEV1/FVC< 70% and respiratory symptoms. Receiver operating characteristic (ROC) curve analysis compared the discriminatory power of the two questionnaires, and stratified by urbanization. Results: We identified 129 spirometry-defined and 92 symptomatic COPD cases out of 1350 enrolled subjects. The optimal cut-off score for the COPD-PS was 4 for spirometry-defined and 5 for symptomatic COPD. The optimum cut-off score for the COPD-SQ was 15 for both spirometry-defined and symptomatic COPD. The COPD-PS and COPD-SQ had similar AUC values for spirometry-defined (0.672 vs 0.702) and symptomatic COPD (0.734 vs 0.779). The AUC of the COPD-SQ tended to be higher in rural areas than that of the COPD-PS for spirometry-defined COPD (0.700 vs 0.653, P = 0.093). Conclusion: The COPD-PS and COPD-SQ had comparable discriminatory power for detecting COPD in the general population while the COPD-SQ performed better in rural areas. A pilot study for validating and comparing the diagnostic accuracy of different questionnaires is required when screening for COPD in a new environment.

1 June 2024 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
BLBoyu Li
Boyu Li
MLMeishan Liu
Meishan Liu
YWYing Wang
Ying Wang
HZHong Zhang
Hong Zhang
LXLingling Xuan
Lingling Xuan
ZAZhuoling An
Zhuoling An
Purpose: Vitamin D deficiency (VDD, 25-hydroxyvitamin D < 20 ng/mL) has been reported associated with exacerbation of chronic obstructive pulmonary disease (COPD) but sometimes controversial. Research on severe vitamin D deficiency (SVDD, 25-hydroxyvitamin D < 10 ng/mL) in exacerbation of COPD is limited. Patients and Methods: We performed a retrospective observational study in 134 hospitalized exacerbated COPD patients. 25-hydroxyvitamin D was modeled as a continuous or dichotomized (cutoff value: 10 or 20 ng/mL) variable to evaluate the association of SVDD with hospitalization in the previous year. Receiver operator characteristic (ROC) analysis was performed to find the optimal cut-off value of 25-hydroxyvitamin D. Results: In total 23% of the patients had SVDD. SVDD was more prevalent in women, and SVDD group tended to have lower blood eosinophils counts. 25-hydroxyvitamin D level was significantly lower in patients who were hospitalized in the previous year (13.6 vs 16.7 ng/mL, P = 0.044), and the prevalence of SVDD was higher (38.0% vs 14.3%, P = 0.002). SVDD was independently associated with hospitalization in the previous year [odds ratio (OR) 4.34, 95% CI 1.61– 11.72, P = 0.004] in hospitalized exacerbated COPD patients, whereas continuous 25-hydroxyvitamin D and VDD were not (P = 0.1, P = 0.9, separately). The ROC curve yielded an area under the curve of 0.60 (95% CI 0.50– 0.71) with an optimal 25-hydroxyvitamin D cutoff of 10.4 ng/mL. Conclusion: SVDD probably showed a more stable association with hospitalization in the previous year in hospitalized exacerbated COPD patients. Reasons for lower eosinophil counts in SVDD group needed further exploration.

1 April 2025 in Journal of Asthma and Allergy
Verified
Journal Article
Open access
PDF file
XYXuwen Yang
Xuwen Yang
MLMeishan Liu
Meishan Liu
HSHonglei Shi
Honglei Shi
MHMengjia Hu
Mengjia Hu
YLYong Lu
Yong Lu
KHKewu Huang
Kewu Huang
Purpose: To investigate the effectiveness of impulse oscillometry (IOS) and its combination with fractional expiratory nitric oxide (FeNO) in distinguishing inadequately controlled asthma (ICA) from well-controlled asthma (WCA) in adults. Patients and Methods: Adult patients aged 18 and above with asthma were recruited and underwent routine blood tests, FeNO, IOS, and spirometry before and after bronchodilator administration on the same day. Asthma control level was assessed using Asthma Control Test (ACT) scores; WCA was defined as a score above 20, while ICA was defined as a score of 20 or below. Receiver operating characteristic curve (ROC) and logistic regression analyses were employed to determine the relationship between IOS and FeNO measurements and asthma control. Results: The z score values of IOS parameters, specifically resistance at 5 hz (R5), resistance at 20 hz (R20), and the area under reactance curve between 5 hz and resonant frequency (AX) after bronchodilator administration were significantly different between the WCA (n = 75) and ICA (n = 77) groups. IOS parameters, R5, R20, and AX, after bronchodilation identified patients with ICA, with areas under receiver operating characteristic curve (AUC) of 0.654, 0.690, and 0.708, respectively, adjusted for smoke exposure, variable airflow limitation and fixed airflow obstruction. Combining IOS parameters with FeNO significantly increased the AUC (0.728, 0.752, and 0.763) for detecting ICA compared to IOS parameters with R5, R20, and AX, alone. Patients with abnormal IOS and FeNO values had significantly higher odds ratio (OR) of having ICA by logistic regression analyses, especially for abnormally higher AX, with an OR of 6.48. Conclusion: IOS is useful in discriminating ICA from WCA in adults, with its effectiveness further enhanced when combined with FeNO measurements.

1 October 2021 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
EYErlei Yao
Erlei Yao
QSQining Sun
Qining Sun
WLWeichao Li
Weichao Li
MYMiao Yu
Miao Yu
MLMeishan Liu
Meishan Liu
In this study, we investigated the characteristics of the seismic response of a subway shield tunnel beneath a rock mountain through the finite-element method based on a practical subway tunnel project in China. We discuss the influence of the spectral nonstationarity of seismic motion on tunnel responses. First, a set of quasistationary (QS) and fully nonstationary (FN) bedrock motions were artificially simulated. Second, the background information of the referenced project was briefly discussed, and correspondingly, several refined numerical models were established. Finally, the mutual relationship between a subway tunnel and the overlying rock mountains under QS bedrock motions was studied, and the results under the QS and FN bedrock motions were compared to clarify the effect of the spectral nonstationarity of ground motions. We found that i) an overlying rock mountain can suppress the acceleration response of an underground tunnel, and combined with the seismic motion, high confining pressure owing to the existence of an overlying mountain aggravates the radial shear-stress response and damage to the tunnel; ii) the spectral nonstationarity of input motions results in higher acceleration responses at the mountaintop and on the tunnel and causes greater radial shear stress and damage to the tunnel, even though the input PGAs and waveforms for QS and FN motions are the same. Therefore, artificial seismic motions exhibiting spectral nonstationarity may provide conservative results.

1 January 2026 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
BLBoyu Li
Boyu Li
MLMeishan Liu
Meishan Liu
HSHonglei Shi
Honglei Shi
YWYing Wang
Ying Wang
XMXiaoni Meng
Xiaoni Meng
ZAZhuoling An
Zhuoling An
Background: The association between relative changes in fractional exhaled nitric oxide (FeNO) in chronic obstructive pulmonary disease (COPD) with patient-reported symptoms improvements remains uncertain. Objective: To assess the association of the rate of FeNO decline with the achievement of the minimum clinically important difference (MCID) in COPD Assessment Test (CAT) score. Methods: We conducted a single-center, retrospective real-world study involving 111 adults with COPD. Patients were classified into two groups: those with symptom improvement (CAT decline ≥ 2 points) and those with no improvement (CAT decline < 2 points). Logistic regression evaluated associations between FeNO decline rate and CAT MCID, adjusting for clinically relevant covariates. Receiver operating characteristic (ROC) curve analysis estimated the discriminatory performances of it. Results: Of 111 patients, 53 (47.7%) achieved the CAT MCID. Multivariate logistic regression found that the rate of FeNO decline was independently associated with symptom improvement (adjusted OR 2.08, 95% CI 1.01– 4.29, P=0.047). Baseline CAT also showed association with symptom improvement (adjusted OR 1.06, 95% CI 1.00– 1.12, P=0.034). BMI showed a positive trend but without statistical significance (adjusted OR 1.13, 95% CI 1.00– 1.29, P=0.056). AUC of FeNO decline rate, baseline CAT, combined with BMI in discriminating CAT MCID were 0.713 (95% CI 0.617, 0.809). Conclusion: The rate of FeNO decline was significantly associated with clinically meaningful CAT improvement in this study, which indicated dynamic measures of type-2 inflammation can complement blood eosinophil counts to refine phenotyping and inform precision management in COPD.