F. Levent Degertekin

F. Levent Degertekin

Auto-generated profile, based on publicly available information

F. Levent Degertekin

School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2006 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
AOA. G. Onaran
A. G. Onaran
MBM. Balantekin
M. Balantekin
WLW. Lee
W. Lee
WHW. L. Hughes
W. L. Hughes
BBB. A. Buchine
B. A. Buchine
FDF. L. Degertekin
F. L. Degertekin
We introduce a novel probe structure for the atomic force microscope. The probe has a sharp tip placed on a micromachined membrane with an integrated displacement sensor, a diffraction-based optical interferometer. We use this probe in a microscope to directly measure the transient interaction forces between the probe tip and the sample when operating in a dynamic mode. We form images related to viscoelasticity and adhesion of the samples by recording salient features of individual tap signals. We also produce tapping mode images of sample topography an order of magnitude faster than current probe microscopes using an integrated electrostatic actuator to move the probe tip. We envision a broad range of applications for this device that range from life sciences to microelectronics.

16 November 2022 in Science Advances
Verified
Journal Article
Open access
HLHohyun Lee
Hohyun Lee
YGYutong Guo
Yutong Guo
JRJames L. Ross
James L. Ross
SSScott Schoen
Scott Schoen
FDF. Levent Degertekin
F. Levent Degertekin
CACostas Arvanitis
Costas Arvanitis
Despite the challenges in treating glioblastomas (GBMs) with immune adjuvants, increasing evidence suggests that targeting the immune cells within the tumor microenvironment (TME) can lead to improved responses. Here, we present a closed-loop controlled, microbubble-enhanced focused ultrasound (MB-FUS) system and test its abilities to safely and effectively treat GBMs using immune checkpoint blockade. The proposed system can fine-tune the exposure settings to promote MB acoustic emission–dependent expression of the proinflammatory marker ICAM-1 and delivery of anti-PD1 in a mouse model of GBM. In addition to enhanced interaction of proinflammatory macrophages within the PD1-expressing TME and significant improvement in survival ( P < 0.05), the combined treatment induced long-lived memory T cell formation within the brain that supported tumor rejection in rechallenge experiments. Collectively, our findings demonstrate the ability of MB-FUS to augment the therapeutic impact of immune checkpoint blockade in GBMs and reinforce the notion of spatially tumor-targeted (loco-regional) brain cancer immunotherapy.

1 December 2011 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
CTCoskun Tekes
Coskun Tekes
MKMustafa Karaman
Mustafa Karaman
FDF. Levent Degertekin
F. Levent Degertekin
Forward-looking (FL) catheter-based imaging systems are highly desirable for guiding interventions in intra- vascular ultrasound (IVUS) applications. One of the main challenges of array-based FL-IVUS systems is the large channel count, which results in increased system complexity. Synthetic phased-array processing with a reduced firing count simplifies the front-end and, hence, can enable 3-D real-time imaging. Recently, we have investigated dual-ring arrays suitable for IVUS imaging, in which the two concentric circular arrays are used separately as transmit (Tx) and receive (Rx) arrays. In this study, we present different optimized array designs based on dual and single circular rings which are suitable for synthetic phased-array processing with a reduced number of firings. To obtain an optimal firing set that produces low side lobes in the wideband response, we use a simulated annealing algorithm. In the simulations, we use 1.2-mm-diameter array configurations with 64 Tx and 58 Rx elements, a center frequency of 20 MHz and fractional bandwidths of 50% and 80%. The results show that optimized dual-ring arrays provide 8 dB improvements in peak near side-lobe level with no widening in the main lobe width when compared with full and other sparse co-arrays.

1 April 2010 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Closed access
TFThomas P. Forbes
Thomas P. Forbes
FDF. Levent Degertekin
F. Levent Degertekin
AFAndrei G. Fedorov
Andrei G. Fedorov

17 August 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
SSSushruta Surappa
Sushruta Surappa
MTMolei Tao
Molei Tao
FDF. Levent Degertekin
F. Levent Degertekin
There is an increasing interest in wireless power transfer for medical implants, sensor networks, and consumer electronics. A passive capacitive parametric ultrasonic transducer (CPUT) can be suitable for these applications as it does not require a dc bias or a permanent charge. In this paper, we present a 1-D lumped parameter model of the CPUT to study its operation and investigate relevant design parameters for power transfer applications. The CPUT is modeled as an ultrasound-driven piston coupled to an RLC resonator resulting in a system of two coupled nonlinear ordinary differential equations. Simulink is used along with an analytical approximation of the system to obtain the voltage across the capacitor and displacement of the piston. Parametric resonance threshold and ultrasound-to-electrical conversion efficiency are evaluated, and the dependence of these performance metrics on the load resistance, input ultrasound intensity, forcing frequency, electrode coverage area, gap height, and the mechanical Q-factor are studied. Based on this analysis, design guidelines are proposed for highly efficient power transfer. Guided by these results, practical device designs are obtained through COMSOL simulations. Finally, the feasibility of using the CPUT in air is predicted to set the foundation for further research in ultrasonic wireless power transfer, energy harvesting, and sensing.

6 May 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ARAhmad Rezvanitabar
Ahmad Rezvanitabar
GJGwangrok Jung
Gwangrok Jung
YYYusuf Samet Yaras
Yusuf Samet Yaras
FDF. Levent Degertekin
F. Levent Degertekin
MGMaysam Ghovanloo
Maysam Ghovanloo
A power-efficient bridge-to-digital sensing interface is proposed, which also offers immunity against power supply noise. The interface utilizes duty-cycling to reduce the static power consumption of resistive bridge sensors, which are commonly used in implantable, wearable, and internet of things (IoT) applications, such as intracranial pressure (ICP) sensing and blood pressure (BP) monitoring. The proposed interface uses a revised version of the pseudo-pseudo differential (PPD) topology with the ping-pong technique to reduce the complexity of traditional fully-differential counterparts. A proof-of-concept prototype has been fabricated in 0.35-μm CMOS and occupies an active area of 0.48 mm 2 . It achieves 9.13 effective number of bits (ENOB) at 3.72 kHz sampling rate and improvement of more than 50 dB in the power supply rejection ratio (PSRR) by employing the ping-pong technique. It reduces the power consumption of a 5-kΩ Wheatstone bridge by 99.6% compared to a traditional interface, down to 2.53 μw at 1.8 V supply. The functionality of the system has also been demonstrated in an experimental setup in conjunction with an embedded resistive bridge pressure sensor.