27 May 2025 in Metrologia
A new caesium (Cs) fountain clock NIM6 has been developed at the National Institute of Metrology (NIM) in China, for which a comprehensive uncertainty evaluation is presented. A three-dimensional magneto-optical trap loading optical molasses is employed to obtain more cold atoms rapidly and efficiently with a tunable, uniform density distribution. A heat pipe surrounding the flight tube maintains a consistent and stable temperature within the interrogation region. Additionally, a Ramsey cavity with four azimuthally distribution feeds is utilized to mitigate distributed cavity phase shifts. The Cs fountain clock NIM6 achieves a short-term fractional frequency instability of 1.0 × 10 −13 τ −1/2 at high atomic density, and a typical overall fractional type-B uncertainty is estimated to be 2.2 × 10 −16 . Comparisons of frequency between the Cs fountain NIM6 and other Cs fountain primary frequency standards through Coordinated Universal Time have demonstrated an agreement within the stated uncertainties.
1 July 2025 in AIP Advances
The 369.5 nm laser serves as the cooling laser for ytterbium-ion optical clocks, and its frequency instability directly affects the intensity of ion fluorescence. This paper compares two stabilization methods for a 369.5 nm frequency-tripled fiber laser: locking to a femtosecond optical frequency comb (FOFC) and locking to a wavelength meter. The FOFC-locked laser achieves a frequency instability of 2.85 × 10−13 at 1 s, three orders of magnitude lower than that of the wavelength meter-locked laser. Fluorescence variations from a single Yb+ ion are monitored under both locking schemes; the FOFC lock produces less than half the fluorescence fluctuation observed with the wavelength meter lock, thereby improving the signal-to-noise ratio. The reduced fluorescence noise lowers the quantum projection noise of the Yb+ optical clock, enabling the attainment of lower overall clock instability.
10 April 2026 in IEEE Transactions on Instrumentation and Measurement
Compact cold-atom frequency standards, characterized by low frequency drift and high accuracy, continue to attract significant interest to address the growing demand for portable, high-performance time-keeping solutions. This paper presents and experimentally demonstrates a proof-of-principle prototype of a compact cold-atom Ramsey clock. The system is based on a multi-standing-wave field microwave cavity operating in the TE₀₁₃ mode and employs a free-falling atom scheme to simplify optical frequency control. The chosen TE₀₁₃ cavity is a cylindrical microwave resonator (CMR) fabricated from oxygen-free copper (OFC), which offers advantages in size and microwave leakage control over the conventional TE₀₁₁ cavity for this free-fall configuration. Its structure, which also serves as the vacuum chamber, is sealed with ceramic windows and coupled via rectangular waveguides. During operation, atoms interact with the first and third standing-wave fields to implement Ramsey interrogation. Experimental results show optimal pulse timing with τ1=16 ms, which aligns closely with theoretical predictions (τ1=16.1 ms). The measured central Ramsey fringe has a full width at half maximum (FWHM) of 8.9 Hz and a contrast of 89.1%, corresponding to a measured relative frequency instability of 6.4×10−13 τ-1/2.
6 March 2026 in Metrologia
5 June 2026 in Physica Scripta
To bridge the gap between the optical clock (OC) technological advancements and their practical implementation, this study develops an ensemble timescale algorithm that integrates discontinuously operated OCs with hydrogen maser (HM) ensembles using two-stage weighted least squares optimization. We conducted a systematic multi-scenario analysis by combining operational cycles of 1, 3, and 7 d with uptimes ranging from 1 to 24 h. This allowed us to quantify the effectiveness of the OC in estimating the frequency drift of HMs and their impact on timescale stability. Experimental validation demonstrates that OCs operating ⩾2 h d -1 , ⩾5 h every 3 d, or ⩾24 h/week achieve equivalent frequency drift assessment accuracy to a cesium fountain clock (CsF). Notably, with 12-hour daily operation, the OC-integrated timescale attains a stability of 1.07 × 10 −16 at 3.6 × 10 6 s, which represents a 192% and 839% improvement over CsF-integrated timescales and HM-only timescales. This research establishes a comprehensive theoretical and experimental validation for OC integration in timescale generation.