Pavel V. Grachev

Pavel V. Grachev

Auto-generated profile, based on publicly available information

Pavel V. Grachev

Prokhorov General Physics Institute of the Russian Academy of Sciences

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 September 2016 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
DPDaria Pominova
Daria Pominova
Anastasia V RyabovaAnastasia V Ryabova
Anastasia V Ryabova
PGPavel V. Grachev
Pavel V. Grachev
IRIgor Romanishkin
Igor Romanishkin
SKSergey Kuznetsov
Sergey Kuznetsov
Victor LoschenovVictor Loschenov
Victor Loschenov
The great interest in upconversion nanoparticles exists due to their high efficiency under multiphoton excitation. However, when these particles are used in scanning microscopy, the upconversion luminescence causes a streaking effect due to the long lifetime. This article describes a method of upconversion microparticle luminescence lifetime determination with help of modified Lucy–Richardson deconvolution of laser scanning microscope (LSM) image obtained under near-IR excitation using nondescanned detectors. Determination of the upconversion luminescence intensity and the decay time of separate microparticles was done by intensity profile along the image fast scan axis approximation. We studied upconversion submicroparticles based on fluoride hosts doped with Yb3+-Er3+ and Yb3+-Tm3+ rare earth ion pairs, and the characteristic decay times were 0.1 to 1.5 ms. We also compared the results of LSM measurements with the photon counting method results; the spread of values was about 13% and was associated with the approximation error. Data obtained from live cells showed the possibility of distinguishing the position of upconversion submicroparticles inside and outside the cells by the difference of their lifetime. The proposed technique allows using the upconversion microparticles without shells as probes for the presence of OH− ions and CO2 molecules.

25 March 2014 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
MKMaria N. Kholodtsova
Maria N. Kholodtsova
PGPavel V. Grachev
Pavel V. Grachev
TSTatiana Savelieva
Tatiana Savelieva
NKNina Kalyagina
Nina Kalyagina
WBWalter Blondel
Walter Blondel
VLViktor B. Loschenov
Viktor B. Loschenov
Appropriate analysis of biological tissue deep regions is important for tumor targeting. This paper is concentrated on photons’ paths analysis in such biotissue as brain, because optical probing depth of fluorescent and excitation radiation differs. A method for photon track reconstruction was developed. Images were captured focusing on the transparent wall close and parallel to the source fibres, placed in brain tissue phantoms. The images were processed to reconstruct the photons most probable paths between two fibres. Results were compared with Monte Carlo simulations and diffusion approximation of the radiative transfer equation. It was shown that the excitation radiation optical probing depth is twice more than for the fluorescent photons. The way of fluorescent radiation spreading was discussed. Because of fluorescent and excitation radiation spreads in different ways, and the effective anisotropy factor,geff, was proposed for fluorescent radiation. For the brain tissue phantoms it were found to be0.62±0.05and0.66±0.05for the irradiation wavelengths 532 nm and 632.8 nm, respectively. These calculations give more accurate information about the tumor location in biotissue. Reconstruction of photon paths allows fluorescent and excitation probing depths determination. Thegeffcan be used as simplified parameter for calculations of fluorescence probing depth.

18 February 2020 in Methods and Applications in Fluorescence
Verified
Journal Article
Open access
PDF file
DPDaria Pominova
Daria Pominova
IRIgor Romanishkin
Igor Romanishkin
VPVera Yu Proydakova
Vera Yu Proydakova
PGPavel V Grachev
Pavel V Grachev
AMArkadiy S Moskalev
Arkadiy S Moskalev
Victor LoschenovVictor Loschenov
Victor Loschenov
Upconversion nanoparticles have attracted considerable attention as luminescent markers for bioimaging and sensing due to their capability to convert near-infrared (NIR) excitation into visible or NIR luminescence. However, the wavelength of about 970 nm is commonly used for the upconversion luminescence excitation, where the strong absorption of water is observed, which can lead to laser-induced overheating effects. One of the strategies for avoiding such laser-induced heating involves shifting the excitation into shorter wavelengths region. However, the influence of wavelength change on luminescent images quality has not been investigated yet. In this work, we compare wavelengths of 920, 940 and 970 nm for upconversion luminescence excitation in the thickness of biological tissues in terms of detected signal intensity and obtained image quality (contrast and signal-to-background ratio). Studies on biological tissue phantoms with various scattering and absorbing properties were performed to analyze the influence of optical parameters on the depth and contrast of the images obtained under 920–970 nm excitation. It was shown that at the same power the excitation wavelength shift reduces the detected signal intensity and the resulting image contrast. Visualization of biological tissue samples using shorter excitation wavelengths 920 and 940 nm also reduces signal-to-background ratio (S/B) of the obtained images. The S/B of the obtained images amounted to 2, 6 and 8 for 920, 940 and 970 nm, respectively. It was demonstrated that pulse-periodic excitation mode is preferable for obtaining high quality luminescent images of biological tissues deep layers and minimize overheating. Short pulse durations (duty cycle 20%) don’t result in heating even for 1 W cm−2 pumping power density and allow obtaining high luminescence intensity, which provides good images quality.

21 March 2022 in Methods and Applications in Fluorescence
Verified
Journal Article
Closed access
PDF file
DPDaria Pominova
Daria Pominova
IRIgor Romanishkin
Igor Romanishkin
VPVera Proydakova
Vera Proydakova
SKSergey Kuznetsov
Sergey Kuznetsov
PGPavel Grachev
Pavel Grachev
Victor LoschenovVictor Loschenov
Victor Loschenov
Upconversion materials have several advantages for many applications due to their great potential in converting infrared light to visible. For practical use, it is necessary to achieve high intensity of UC luminescence, so the studies of the optimal synthesis parameters for upconversion nanoparticles are still going on. In the present work, we analyzed the synthesis temperature effect on the efficiency and luminescence decay of β -NaGd 0.78 Yb 0.20 Er 0.02 F 4 (15–25 nm) upconversion nanoparticles with hexagonal crystal structure synthesized by anhydrous solvothermal technique. The synthesis temperature was varied in the 290 °C–320 °C range. The synthesis temperature was shown to have a significant influence on the upconversion luminescence efficiency and decay time. The coherent scattering domain linearly depended on the synthesis temperature and was in the range 13.1–22.3 nm, while the efficiency of the upconversion luminescence increases exponentially from 0.02 to 0.10% under 1 W cm −2 excitation. For a fundamental analysis of the reasons for the upconversion luminescence intensity dependence on the synthesis temperature, it was proposed to use the maximum entropy method for luminescence decay kinetics processing. This method does not require a preliminary setting of the number of exponents and, due to this, makes it possible to estimate additional components in the luminescence decay kinetics, which are attributed to different populations of rare-earth ions in different conditions. Two components in the green luminescence and one component in the red luminescence decay kinetics were revealed for nanoparticles prepared at 290 °C–300 °C. An intense short and a weak long component in green luminescence decay kinetics could be associated with two different populations of ions in the surface quenching layer and the crystal core volume. With an increase in the synthesis temperature, the second component disappears, and the decay time increases due to an increase in the number of ions in the crystal core volume and a more uniform distribution of dopants.

25 June 2018 in Biomedical Photonics
Verified
Journal Article
Open access
PDF file
MKM. N. Kholodtsova
M. N. Kholodtsova
PGP. V. Grachev
P. V. Grachev
ВБВ. C. Блондель
В. C. Блондель
PZP. V. Zelenkov
P. V. Zelenkov
APA. A. Potapov
A. A. Potapov
VLV. B. Loschenov
V. B. Loschenov
Исследованы возможности применения зонда для стереотаксической биопсии при флуоресцентной навигации при возбуждении 532 или 632,8 нм. Для исследования макроскопических параметров, наблюдаемых во время забора образцов при стереотаксической биопсии с помощью оптического зонда, был сделан набор полужидких, полутвердых многослойных фантомов, моделирующих границу между нормальной мозговой тканью и опухолью с фотосенсибилизатором и наночастицами золота (сферы и звезды) в различных концентрациях. Было проанализировано влияние золотых наносфер и нанозвезд, добавленных в разных концентрациях к нижнему слою фантома, на усиление флуоресценции за счет переноса энергии между наночастицами и флуоресцентными молекулами. Результаты позволяют определить границу опухоли и повысить эффективность биопсии, наблюдая характер изменения флуоресцентного сигнала при прохождении зонда через опухоль.