This paper proposes a new method for the investigation of the short-circuit safe operation area (SCSOA) of state-of-the-art SiC MOSFET power modules rated at 1.2 kV based on the variations in SiC MOSFET electrical parameters (e.g., short-circuit current and gate–source voltage). According to the experimental results, two different failure mechanisms have been identified, both reducing the short-circuit capability of SiC power modules with respect to discrete SiC devices. Based on such failure mechanisms, two short-circuit safety criteria have been formulated: 1) the short-circuit-current-based criterion; and 2) the gate-voltage-based criterion. The applicability of these two criteria makes possible the SCSOA evaluation of SiC MOSFETs with some safety margins in order to avoid unnecessary failures during their SCSOA characterization. SiC MOSFET power modules from two different manufacturers are experimentally tested in order to demonstrate the procedure of the method. The obtained results can be used to have a better insight of the SCSOA of SiC MOSFETs and their physical limits.
This paper presents the impact of repetitive short-circuit tests on the normal operation of a commercial Silicon Carbide (SiC) MOSFET and the influence of different case temperatures on the short-circuit degradation process. To ensure repeatable short-circuit test conditions, the maximum short-circuit withstanding time is studied at three different case temperatures, and the critical energy is identified. In order to investigate the effect of short-circuit stress on the normal operation, the static and dynamic characteristics are periodically measured along with repetitive short-circuit activity. The turn-on switching loss increases gradually with the increasing number of repetitive short-circuit tests. This is associated with the increase of the gate leakage current during the short circuit tests, which shows a reduction of the on-state gate voltage because of the gate oxide degradation. Then, since the case temperature of the device is subject to the operating condition in the application, the degradation process of repetitive short-circuit tests with respect to different case temperatures are investigated, and the relationship between the number of repetitions to failure and the initial case temperature is established. Finally, the case temperature influence is explained by a 1-D transient thermal model based on the short-circuit condition.
5 February 2019 in IEEE Transactions on Power Electronics