Kate Smith

Kate Smith

Auto-generated profile, based on publicly available information

Kate Smith

Department of Mechanical & Manufacturing Engineering, Trinity College

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2016 in Applied Thermal Engineering
Verified
Journal Article
Closed access
KSKate Smith
Kate Smith
SSSamuel Siedel
Samuel Siedel
ARAnthony J. Robinson
Anthony J. Robinson
RKRoger Kempers
Roger Kempers

1 February 2020 in International Journal of Thermofluids
Verified
Journal Article
Open access
ARAnthony J. Robinson
Anthony J. Robinson
KSKate Smith
Kate Smith
THTurlough Hughes
Turlough Hughes
SFSauro Filippeschi
Sauro Filippeschi

1 December 2016 in Experimental Thermal and Fluid Science
Verified
Journal Article
Closed access
KSK. Smith
K. Smith
GBG. Byrne
G. Byrne
RKRoger Kempers
Roger Kempers
ARA.J. Robinson
A.J. Robinson

1 January 2014 in Heat Pipe Science and Technology, An International Journal
Verified
Journal Article
Closed access
PDF file
KSKate Smith
Kate Smith
SSSamuel Siedel
Samuel Siedel
ARAnthony J. Robinson
Anthony J. Robinson
RKRoger Kempers
Roger Kempers
In certain applications geometric constraints may make it impractical to use a straight thermosyphon. This paper aims to characterize the performance of a counter-flow thermosyphon with varying bend angles in the adiabatic section and a range of fluid loadings. The results of this study demonstrate that adequate levels of heat transfer can be achieved with bends in the adiabatic section connecting the evaporator and condenser sections. In general the effects of bend angle and fluid loading had relatively little effect on total thermal resistance. Finally, the failure limit of each thermosyphon was characterized. It was clear from the results obtained that further work is necessary to expand the range of testing parameters to fully understand their influence on the performance of the thermosyphon.

1 January 2014
Verified
Conference Paper
Closed access
KSKate Smith
Kate Smith
RKRoger Kempers
Roger Kempers
ARAnthony J. Robinson
Anthony J. Robinson
SSSamuel Siedel
Samuel Siedel
Heat pipes and thermosyphons are generally recognized as a reliable heat transfer device for many different applications however clarity is needed to describe the thermal mechanisms driving the transfer of heat. This experiment involved the construction and testing of a transparent, sapphire thermosyphon, with water as the working fluid. Through high speed imagery and corresponding temperature and pressure measurements, the dominant mechanisms of boiling and condensation were visualized in the evaporator and condenser. The tests were carried out at various internal pressures, which ranged from P = 4 - 25 kPa, at a constant heat input of Q = 50 W. Of particular interest was the pulsating nature of the thermosyphon at lower pressure levels. The high speed images show, at lower pressures, a liquid plug and vapor slug were seen to oscillate between the evaporator and condenser. At the higher pressures tested, film condensation becomes more dominant in the condenser and the frequency and amplitude of liquid oscillations is reduced. The overall thermal resistance of the system was also calculated, and ranged from Rtot = 0.44 K/W at low pressure, to Rtot = 0.10 K/W at higher pressure.

1 January 2014 in Heat Pipe Science and Technology, An International Journal
Verified
Journal Article
Closed access
PDF file
AFAlessandro Franco
Alessandro Franco
KSKate Smith
Kate Smith
SSSamuel Siedel
Samuel Siedel
ARAnthony J. Robinson
Anthony J. Robinson
RKRoger Kempers
Roger Kempers
Though heat pipes are recognized as viable heat transfer devices for many different applications, the thermal mechanisms driving the heat transfer are still not fully understood. By fabricating and testing a fully transparent, sapphire heat pipe, with water as the working fluid, the dominant mechanisms of boiling and condensation were visualized. The results of this investigation suggest that for low operating pressures there is a complex geyser boiling regime occurring in the evaporator section at lower powers (~20 W). Through all power levels slugs of water and plugs of vapor were observed, similar to a pulsating heat pipe. The regime shifted towards more explosive boiling at higher powers (~70 W). These phenomena were observed using high speed imaging and the corresponding local temperature data.