Kayoko Yamamoto

Kayoko Yamamoto

Auto-generated profile, based on publicly available information

Kayoko Yamamoto

Division of Medicine for Function and Morphology of Sensor Organs, Department of Dentistry and Oral Surgery, Faculty of Medicine, Osaka Medical College, 2-7 Daigakumachi, Takatsuki, Osaka 569-8686, Japan

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2020 in Materials
Verified
Journal Article
Open access
PDF file
尚今尚子 今川
尚子 今川
KIkazuya inoue
kazuya inoue
KMKeisuke Matsumoto
Keisuke Matsumoto
AOAyako Ochi
Ayako Ochi
MOMichi Omori
Michi Omori
TUTakaaki Ueno
Takaaki Ueno
The additive manufacturing (AM) technique has attracted attention as one of the fully customizable medical material technologies. In addition, the development of new surface treatments has been investigated to improve the osteogenic ability of the AM titanium (Ti) plate. The purpose of this study was to evaluate the osteogenic activity of the AM Ti with mixed-acid and heat (MAH) treatment. Fully customized AM Ti plates were created with a curvature suitable for rat calvarial bone, and they were examined in a group implanted with the MAH-treated Ti in comparison with the untreated (UN) group. The AM Ti plates were fixed to the surface of rat calvarial bone, followed by extraction of the calvarial bone 1, 4, 8, and 12 weeks after implantation. The bonding between the bone and Ti was evaluated mechanically. In addition, AM Ti plates removed from the bone were examined histologically by electron microscopy and Villanueva–Goldner stain. The mechanical evaluation showed significantly stronger bone-bonding in the MAH group than in the UN group. In addition, active bone formation was seen histologically in the MAH group. Therefore, these findings indicate that MAH resulted in rapid and strong bonding between cortical bone and Ti.

20 July 2018 in RSC Advances
Verified
Journal Article
Open access
PDF file
KYKayoko Yamamoto
Kayoko Yamamoto
SYSeiji Yamaguchi
Seiji Yamaguchi
TMTomiharu Matsushita
Tomiharu Matsushita
SMShigeo Mori
Shigeo Mori
AHAzumi Hirata
Azumi Hirata
TUTakaaki Ueno
Takaaki Ueno
The practical use of additive manufacturing to create artificial bone as a material for repairing complex bone defects is currently attracting attention. In this study, we compared the osteogenic capacity of materials composited by the method developed by Kokubo et al. of treating 3D-printed titanium (Ti) mesh with a mixture of H2SO4 and HCl and heating (mixed-acid and heat treatment) with that of materials subjected to conventional chemical treatment. Ti plates treated with this method have been found to promote highly active bone formation on their surface when inserted into rabbit tibial bone defects. No previous study has compared this method with other surface treatment methods. In this study, we used histological and other observations to compare the bone formation process in bone defects when Ti meshes prepared by the selective laser melting technique (SLM) and treated either with mixed acids and heat or with conventional chemical Ti surface treatments were implanted in a rat calvarial bone defect model. We found that both micro-computed tomography and observations of undecalcified ground sections showed that the best bone formation was observed in rats implanted with mesh treated with mixed acids and heat. Our results suggest that mixed-acid and heat-treated Ti mesh prepared by SLM may have a high osteogenic capacity in bone defects.

1 January 2016 in Journal of Hard Tissue Biology
Verified
Journal Article
Open access
PDF file
YNYoichiro Nakajima
Yoichiro Nakajima
TUTakaaki Ueno
Takaaki Ueno
KNKato-kogoe Nahoko
Kato-kogoe Nahoko
KYKayoko Yamamoto
Kayoko Yamamoto
NFNozomu Fukui
Nozomu Fukui
YAYasunori Ariyoshi
Yasunori Ariyoshi
When performing mandibular reconstruction following mandibular segmentectomy, the surgical method that we have been using involves creating a surgical guide plate using a three dimensions model for bending the mandible reconstruction plate. It has been reported that the current method results in an excellent suitability of the graft into the mandible, which allows for a highly esthetic recovery. The purpose of the present study was to evaluate how well the current surgical method enables the grafted bone to suitability within the mandibular defect in terms of esthetics and functionality by measuring masticatory performance using a gummy score method. We enrolled 11 patients who had undergone mandibular reconstruction using the current method following mandibular tumorectomy at Osaka Medical College Hospital. Among them, 6 evaluable patients were examined using the gummy score method and occlusal force measurement two months after the operation. Gummy score evaluations were performed while masticating on a whole and then a half-portion gummy jelly, taking into account the decline in occlusal force. The results revealed a declining tendency in masticatory performance and occlusal force; however, adequate masticatory performance was obtained with the half-portion gummy jelly. We believe that the gummy score method using a test gummy jelly is a useful tool in evaluating whether a functionally good suitability between the grafted bone and the mandible has been achieved after mandibular reconstruction using the current method.