Raphael Sivera

Raphael Sivera

Auto-generated profile, based on publicly available information

Raphael Sivera

Affiliation Institute of Cardiovascular Science, University College London, London, United Kingdom

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
LSLiam Swanson
Liam Swanson
RSRaphaël Sivera
Raphaël Sivera
CCClaudio Capelli
Claudio Capelli
AAAbdulaziz Alosaimi
Abdulaziz Alosaimi
DMDariusz Mroczek
Dariusz Mroczek
SSSilvia Schievano
Silvia Schievano
Assessment of the right ventricular outflow tract and pulmonary arteries (RVOT) for percutaneous pulmonary valve implantation (PPVI) uses discrete measurements (diameters and lengths) from medical images. This multi-centre study identified the 3D RVOT shape features prevalent in patients late after surgical repair of congenital heart disease (CHD). A 3D RVOT statistical shape model (SSM) was computed from 81 retrospectively selected CHD patients (14.7 ± 6.8 years) who required pulmonary valve replacement late after surgical repair. A principal component analysis identified prevalent shape features (modes) within the population which were compared with standard geometric measurements (diameter, length and surface area) and between sub-groups of diagnosis, RVOT type and dysfunction. Shape mode 1 and 2 represented RVOT size and curvature and tapering and length, respectively. Shape modes 3–5 related to branch pulmonary artery calibre, conical vs. bulbous RVOTs and RVOT curvature, respectively. Tetralogy of Fallot, transannular patch type and regurgitant RVOTs were larger and straighter while conduit and stenotic types were longer and more cylindrical than other subgroups. This SSM analysed the main 3D shape features present in a population of RVOTs, exploiting the wide 3D anatomical information provided by routine imaging. This morphological information may have implications for PPVI patient selection and device design.

29 July 2024 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
CRClaire Rosnel
Claire Rosnel
RSRaphael Sivera
Raphael Sivera
ECElena Cervi
Elena Cervi
MDMark Danton
Mark Danton
SSSilvia Schievano
Silvia Schievano
AAAnkush Aggarwal
Ankush Aggarwal
Although tissue stiffness is known to play an important role in aortic dilatation, the current guidelines for offering preventative surgery in patients with Marfan syndrome rely solely on the aortic diameter. In this systematic review and meta-analysis, we analyze and compare literature on in vivo aortic stiffness measures in Marfan patients. Our aim is to assess the potential of these measurements as early indicators of aortic dilatation. Following the PRISMA guidelines, we collected literature on diameter and three in vivo stiffness measures: Pulse wave velocity (PWV), $$\beta $$ β -stiffness index (SI) and distensibility, at five different aortic locations in patients with Marfan syndrome. Results were reviewed and compared against each other. For meta-analysis, an augmented dataset was created by combining data from the literature. Regression with respect to age and statistical comparisons were performed. Thirty articles reporting data from 1925 patients with Marfan and 836 patients without Marfan were reviewed. PWV was found to be higher in Marfan, but only in dilated aortas. Distensibility was found to be lower even in non-dilated aortas, and its decrease was associated with higher chances of developing aortic dilatation. $$\beta $$ β -SI was higher in Marfan patients and was positively correlated with the rate of aortic dilatation, emphasizing its role as a valuable indicator. In our meta-analysis, all stiffness measures showed a significant variation with age. Distensibility and $$\beta $$ β -stiffness index were different in Marfan patients at all locations, and the difference was more pronounced after accounting for age-related variation. From the literature, $$\beta $$ β -SI and distensibility emerge as the best predictors of future aortic dilatation. Our meta-analysis quantifies age-related changes in aortic stiffness and highlights the importance of accounting for age in comparing these measurements. Missing diameter values in the literature limited our analysis. Further investigation of criteria combining stiffness and diameter is recommended to better assist clinical decisions for prophylactic surgery.

21 July 2025 in PLOS Digital Health
Verified
Journal Article
Open access
PDF file
RSRaphaël Sivera
Raphaël Sivera
EMEbba Montgomery-Liljeroth
Ebba Montgomery-Liljeroth
YCYaxi Chen
Yaxi Chen
SSSilvia Schievano
Silvia Schievano
JBJan Brüning
Jan Brüning
CCClaudio Capelli
Claudio Capelli
Aortic stenosis (AS) is a common valvular disease becoming more prevalent globally due to the aging of the population. Transcatheter aortic valve implantation (TAVI) is a minimally invasive intervention indicated for AS patients as alternative to surgical replacement. TAVI is to date an established procedure. However, it has been often associated with complications such as paravalvular leakage (PVL) or conduction abnormalities. Evidence of associations between morphological features of the aortic root, valve calcification measurements and suboptimal procedural outcomes have been suggested but the analyses were limited by availability and reproducibility of clinical measurements. In this work, we aim to enrich the characterization of AS patients referred for TAVI by analyzing the clinical findings in conjunction with advanced morphological analysis of the implantation site including aortic root, left ventricular outflow tract and 3D calcification patterns. A population of consecutive patients with AS (n = 130) who underwent TAVI at our clinical centre were retrospectively selected for this study. Demographic and clinical measurements were collected before and after TAVI. Pre-operative CT images were used to reconstruct 3D models of patient-specific anatomies. Statistical shape modelling was carried out and outcomes were analyzed in conjunction with clinical outcomes. The 3D modelling of the valve calcification rate matched previous clinical descriptions; including the crescent shapes visible on each leaflet and the higher calcification rate of the non-coronary cusp. Higher calcification rate was found in larger valves together with a positive association between each coronary height and the calcification of their respective leaflet. Sexual dimorphism, on both shape and calcification, was recorded beyond the size differences with straighter aortas and higher calcification rate at the junction between the left and right coronary leaflets for males compared to females. Morphological differences were significantly associated (p = 0.005) with PVL assessments based on post-operative echocardiograms. Larger aortas and shorter left coronary sinus were associated with less leakage. The outcome distribution appeared to be directly affected by sexual differences and device design. Female phenotypes, smaller and more conic aortic root, were associated with worse outcome. Different patterns in calcification distribution on the leaflets were identified but the association with outcomes is not conclusive. In the future, the presented morphological characterization of patients with AS could contribute to predict post-TAVI PVL and design and test improved TAVI devices.

4 November 2022 in arXiv
Verified
Preprint
Open access
PDF file
EPEndrit Pajaziti
Endrit Pajaziti
JMJavier Montalt-Tordera
Javier Montalt-Tordera
CCClaudio Capelli
Claudio Capelli
RSRaphael Sivera
Raphael Sivera
ESEmilie Sauvage
Emilie Sauvage
VMVivek Muthurangu
Vivek Muthurangu
Computational fluid dynamics (CFD) can be used to simulate vascular haemodynamics and analyse potential treatment options. CFD has shown to be beneficial in improving patient outcomes. However, the implementation of CFD for routine clinical use is yet to be realised. Barriers for CFD include high computational resources, specialist experience needed for designing simulation set-ups, and long processing times. The aim of this study was to explore the use of machine learning (ML) to replicate conventional aortic CFD with automatic and fast regression models. Data used to train/test the model consisted of 3,000 CFD simulations performed on synthetically generated 3D aortic shapes. These subjects were generated from a statistical shape model (SSM) built on real patient-specific aortas (N=67). Inference performed on 200 test shapes resulted in average errors of 6.01% +/-3.12 SD and 3.99% +/-0.93 SD for pressure and velocity, respectively. Our ML-based models performed CFD in +/-0.075 seconds (4,000x faster than the solver). This proof-of-concept study shows that results from conventional vascular CFD can be reproduced using ML at a much faster rate, in an automatic process, and with high accuracy.