Sivakumar Velautham

Sivakumar Velautham

Auto-generated profile, based on publicly available information

Sivakumar Velautham

Department of Physics University of Peradeniya Peradeniya Sri Lanka

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2022 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
SWSachith Welarathna
Sachith Welarathna
SVSivakumar Velautham
Sivakumar Velautham
WWW.M.N.M.B. Wanninayake
W.M.N.M.B. Wanninayake
SSSivananthan Sarasanandarajah
Sivananthan Sarasanandarajah
The present study was conducted as part of a comprehensive work to establish National Diagnostic Reference Levels (NDRLs) in Sri Lanka for the first time. DRLs can be used as an effective optimization tool for identifying unusually high or low patient doses during X‐ray examinations. This study aims to propose institutional DRLs (IDRLs) by measuring the kerma‐area product (KAP) of adult patients undergoing routine projection X‐ray examinations. The median and the 75th percentile KAP values obtained were compared with that of the single institution KAP values reported from India and Greece. This descriptive cross‐sectional study was conducted in a public hospital in Uva province, Sri Lanka, with 400 adult patients aged 18–87 years and weighing 58 ± 20 kg. The patient‐specific information (age, sex, weight, and height) and corresponding exposure parameters (tube voltage and current‐exposure time product) were obtained. The KAP values were measured, and descriptive statistics were utilized for data analysis. The median KAP values obtained were proposed as IDRLs. The IDRLs in Gy.cm2 were 0.23 for cervical spine anterior–posterior (AP), 0.19 for cervical spine lateral (LAT), 0.10 for chest posterior–anterior (PA), 0.06 for knee joint AP, 0.05 for knee joint LAT, 1.47 for KUB AP, 0.85 for lumbar spine AP, 1.97 for lumbar spine LAT, 0.29 for shoulder joint AP, 0.61 for skull PA, and 0.60 for skull LAT examinations. The maximum to minimum ratio of KAP values ranged from 2.4 for KUB AP to 6.3 for the cervical spine AP examinations. The median and the 75th percentile of most of the examinations were comparable to corresponding KAP values reported by the countries mentioned above, except for the skull PA and LAT examinations. Accordingly, interquartile ranges of exposure parameters are recommended for skull examinations to improve the optimization of patient doses.

3 October 2023 in Journal of Radiological Protection
Verified
Journal Article
Closed access
SWSachith Welarathna
Sachith Welarathna
SVSivakumar Velautham
Sivakumar Velautham
SSSivananthan Sarasanandarajah
Sivananthan Sarasanandarajah
The establishment of diagnostic reference levels (DRLs) is an effective tool for optimising radiation doses delivered to patients during medical imaging procedures. This study aimed to compare the institutional DRLs (IDRLs) and propose a multi-centric diagnostic reference level (MCDRL) for chest x-ray examinations in adult patients in Sri Lanka. A prospective cross-sectional study was conducted with 1091 adult patients across six major tertiary care hospitals. Data on patient characteristics, such as age, sex, weight, and body mass index, and exposure parameters, such as tube voltage (kVp) and the product of tube current and exposure time (mAs), were collected. Patient doses were measured in terms of kerma-area product (PKA) using a PKA meter mounted on the collimator of the x-ray tube. IDRLs were computed for each hospital according to the International Commission on Radiological Protection guidelines, and the 75th percentile PKA was used to propose the MCDRL. The relationship between patient weight and exposure parameters was examined using Spearman’s rank correlation to investigate the radiographic practice among hospitals. Results showed that IDRLs varied from 0.10 to 0.26 Gy cm2. The proposed MCDRL was 0.23 Gy cm2, substantially higher than the recently published DRLs from other countries. The median kVp ranged from 95 to 104, while mAs ranged from 2.5 to 5.6. Large variations in the PKA and exposure parameters were observed within and among hospitals. The elevated PKA values observed in this study were mostly due to the use of high mAs in clinical practice. The weak correlation observed between patient weight and exposure parameters suggests the need to standardise examination protocols concerning patient size. The observed dose variations demonstrate the need for the establishment of national DRLs. Until then, the proposed MCDRL can be considered as the benchmark dose level for chest x-ray examinations in Sri Lanka.

5 April 2024 in Journal of Radiological Protection
Verified
Journal Article
Closed access
SWSachith Welarathna
Sachith Welarathna
SVSivakumar Velautham
Sivakumar Velautham
SSSivananthan Sarasanandarajah
Sivananthan Sarasanandarajah
Diagnostic reference levels (DRLs) and achievable doses (ADs) provide guidance to optimise radiation doses for patients undergoing medical imaging procedures. This multi-centre study aimed to compare institutional DRLs (IDRLs) across hospitals, propose ADs and multi-centric DRLs (MCDRLs) for four common x-ray examinations in Sri Lanka, and assess the potential for dose reduction. A prospective cross-sectional study of 894 adult patients referred for abdomen anteroposterior (AP), kidney-ureter-bladder (KUB) AP, lumbar spine AP, and lumbar spine lateral (LAT) x-ray examinations was conducted. Patient demographic information (age, sex, weight, BMI) and exposure parameters (tube voltage, tube current-exposure time product) were collected. Patient dose indicators were measured in terms of kerma-area product (PKA) using a PKA meter. IDRLs, ADs, and MCDRLs were calculated following the International Commission on Radiological Protection guidelines, with ADs and MCDRLs defined as the 50th and 75th percentiles of the median PKA distributions, respectively. IDRL ranges varied considerably across hospitals: 1.42–2.42 Gy cm2 for abdomen AP, 1.51–2.86 Gy cm2 for KUB AP, 0.83–1.65 Gy cm2 for lumbar spine AP, and 1.76–4.10 Gy cm2 for lumbar spine LAT. The proposed ADs were 1.82 Gy cm2 (abdomen AP), 2.03 Gy cm2 (KUB AP), 1.27 Gy cm2 (lumbar spine AP), and 2.21 Gy cm2 (lumbar spine LAT). MCDRLs were 2.24 Gy cm2 (abdomen AP), 2.40 Gy cm2 (KUB AP), 1.43 Gy cm2 (lumbar spine AP), and 2.38 Gy cm2 (lumbar spine LAT). Substantial intra- and inter-hospital variations in PKA were observed for all four examinations. Although ADs and MCDRLs in Sri Lanka were comparable to those in the existing literature, the identified intra- and inter-hospital variations underscore the need for dose reduction without compromising diagnostic information. Hospitals with high IDRLs are recommended to review and optimise their practices. These MCDRLs serve as preliminary national DRLs, guiding dose optimisation efforts by medical professionals and policymakers.

15 July 2025 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
SWSachith Welarathna
Sachith Welarathna
SVSivakumar Velautham
Sivakumar Velautham
SSSivananthan Sarasanandarajah
Sivananthan Sarasanandarajah
Purpose: The increasing prevalence of obesity poses challenges for dose optimization in projection radiography due to greater anatomical thickness in overweight and obese patients worldwide. Diagnostic reference levels (DRLs) alone may not adequately account for variations in body habitus, potentially leading to suboptimal patient protection. This study aimed to explore benchmark doses (BMDs) based on patient body mass index (BMI) for projection radiography examinations of major anatomical regions in Sri Lanka, providing a complementary approach for dose optimization alongside DRLs. Methods: This prospective study included 1989 adult patients (≥18 years) undergoing abdomen anteroposterior (AP), chest posteroanterior (PA), kidney–ureter–bladder (KUB) AP, lumbar spine AP, lumbar spine lateral (LAT), and pelvis AP examinations at six major tertiary care hospitals. For each examination, patient demographics (age, weight, height, and BMI) and exposure parameters (kilovoltage peak [kVp] and tube current‐exposure time product [mAs]) were recorded, and the patient doses in terms of kerma‐area product (P KA ) were measured using a P KA meter. DRLs (achievable doses) were proposed at the median of the median P KA distribution across hospitals for a standard‐sized patient group (58 ± 20 kg). For BMI‐based BMDs, patients were classified into four standard BMI categories: underweight, normal weight, overweight, and obese. The median P KA distributions across hospitals were used to formulate BMI‐based BMDs, which were then compared with the proposed DRLs for the standard‐sized patient group. Results: The results showed a progressive increase in BMI‐based BMDs across BMI categories for all examinations studied. BMI‐based BMDs (in Gy.cm 2 ) for underweight, normal weight, overweight, and obese patients were as follows: 1.46, 1.94, 2.88, 3.00 (abdomen AP); 0.17, 0.21, 0.22, 0.25 (chest PA); 1.70, 1.76, 2.30, 3.60 (KUB AP); 1.00, 1.03, 1.29, 1.48 (lumbar spine AP); 1.94, 2.09, 2.57, 2.56 (lumbar spine LAT); and 0.60, 1.85, 1.86, 2.24 (pelvis AP). Compared to normal weight patients, underweight patients exhibited percentage reductions in BMI‐based BMDs of 24.7%, 3.4%, 2.9%, 7.1%, 4.5%, and 67.6% for abdomen AP, KUB AP, lumbar spine AP, lumbar spine LAT, chest PA, and pelvis AP, respectively. Conversely, overweight patients demonstrated percentage increases of 48.5%, 30.7%, 25.2%, 23.0%, 4.8%, and 0.5% across the same examinations, while obese patients showed increases of 54.6%, 104.5%, 51.5%, 22.5%, 19.0%, and 21.1%, respectively. DRLs for the standard‐sized patient group were 1.82, 0.22, 2.03, 1.27, 2.21, and 1.90 Gy.cm 2 , respectively. Conclusion: These findings underscore the importance of BMI‐based BMDs as an effective tool for personalized dose optimization, accounting for variations in patient body habitus. Their integration into clinical practice, alongside DRLs, could enhance patient protection and promote good radiographic practices. Furthermore, the findings underscore the need for the introduction of international guidelines for DRLs in intervals of BMI to ensure standardized implementation across countries.

31 December 2021 in Journal of the National Science Foundation of Sri Lanka
Verified
Journal Article
Open access
PDF file
SMS. Mubarak
S. Mubarak
DND. Nanayakkara
D. Nanayakkara
CJC. Jayalath
C. Jayalath
VSV. Sivakumar
V. Sivakumar