Sivananthan Sarasanandarajah

Sivananthan Sarasanandarajah

Auto-generated profile, based on publicly available information

Sivananthan Sarasanandarajah

Peter MacCallum Cancer Institute, Melbourne, 3000, Australia

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Physica Medica
Verified
Journal Article
Closed access
JWJeannie Hsiu Ding Wong
Jeannie Hsiu Ding Wong
KNKwan Hoong Ng
Kwan Hoong Ng
SSSivananthan Sarasanandarajah
Sivananthan Sarasanandarajah

20 May 2006 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JKJoseph Kunnil
Joseph Kunnil
SSSivananthan Sarasanandarajah
Sivananthan Sarasanandarajah
ECEasaw Chacko
Easaw Chacko
LRLou Reinisch
Lou Reinisch
The fluorescence spectra of Bacillus spores are measured at excitation wavelengths of 280, 310, 340, 370, and 400  nm. When cluster analysis is used with the principal-component analysis, the Bacillus globigii spores can be distinguished from the other species of Bacillus spores (B. cereus, B. popilliae, and B. thuringiensis). To test how robust the identification process is with the fluorescence spectra, the B. globigii is obtained from three separate preparations in different laboratories. Furthermore the fluorescence is measured before and after washing and redrying the B. globigii spores. Using the cluster analysis of the first two or three principal components of the fluorescence spectra, one is able to distinguish B. globigii spores from the other species, independent of preparing or washing the spores.

19 January 2024 in Radiological Physics and Technology
Verified
Journal Article
Closed access
PDF file
SWSachini Udara Wickramasinghe
Sachini Udara Wickramasinghe
VRVijitha Ramanathan
Vijitha Ramanathan
SSSivananthan Sarasanandarajah
Sivananthan Sarasanandarajah

30 November 2022 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
SWSachith Welarathna
Sachith Welarathna
SVSivakumar Velautham
Sivakumar Velautham
WWW.M.N.M.B. Wanninayake
W.M.N.M.B. Wanninayake
SSSivananthan Sarasanandarajah
Sivananthan Sarasanandarajah
The present study was conducted as part of a comprehensive work to establish National Diagnostic Reference Levels (NDRLs) in Sri Lanka for the first time. DRLs can be used as an effective optimization tool for identifying unusually high or low patient doses during X‐ray examinations. This study aims to propose institutional DRLs (IDRLs) by measuring the kerma‐area product (KAP) of adult patients undergoing routine projection X‐ray examinations. The median and the 75th percentile KAP values obtained were compared with that of the single institution KAP values reported from India and Greece. This descriptive cross‐sectional study was conducted in a public hospital in Uva province, Sri Lanka, with 400 adult patients aged 18–87 years and weighing 58 ± 20 kg. The patient‐specific information (age, sex, weight, and height) and corresponding exposure parameters (tube voltage and current‐exposure time product) were obtained. The KAP values were measured, and descriptive statistics were utilized for data analysis. The median KAP values obtained were proposed as IDRLs. The IDRLs in Gy.cm2 were 0.23 for cervical spine anterior–posterior (AP), 0.19 for cervical spine lateral (LAT), 0.10 for chest posterior–anterior (PA), 0.06 for knee joint AP, 0.05 for knee joint LAT, 1.47 for KUB AP, 0.85 for lumbar spine AP, 1.97 for lumbar spine LAT, 0.29 for shoulder joint AP, 0.61 for skull PA, and 0.60 for skull LAT examinations. The maximum to minimum ratio of KAP values ranged from 2.4 for KUB AP to 6.3 for the cervical spine AP examinations. The median and the 75th percentile of most of the examinations were comparable to corresponding KAP values reported by the countries mentioned above, except for the skull PA and LAT examinations. Accordingly, interquartile ranges of exposure parameters are recommended for skull examinations to improve the optimization of patient doses.

3 October 2023 in Journal of Radiological Protection
Verified
Journal Article
Closed access
SWSachith Welarathna
Sachith Welarathna
SVSivakumar Velautham
Sivakumar Velautham
SSSivananthan Sarasanandarajah
Sivananthan Sarasanandarajah
The establishment of diagnostic reference levels (DRLs) is an effective tool for optimising radiation doses delivered to patients during medical imaging procedures. This study aimed to compare the institutional DRLs (IDRLs) and propose a multi-centric diagnostic reference level (MCDRL) for chest x-ray examinations in adult patients in Sri Lanka. A prospective cross-sectional study was conducted with 1091 adult patients across six major tertiary care hospitals. Data on patient characteristics, such as age, sex, weight, and body mass index, and exposure parameters, such as tube voltage (kVp) and the product of tube current and exposure time (mAs), were collected. Patient doses were measured in terms of kerma-area product (PKA) using a PKA meter mounted on the collimator of the x-ray tube. IDRLs were computed for each hospital according to the International Commission on Radiological Protection guidelines, and the 75th percentile PKA was used to propose the MCDRL. The relationship between patient weight and exposure parameters was examined using Spearman’s rank correlation to investigate the radiographic practice among hospitals. Results showed that IDRLs varied from 0.10 to 0.26 Gy cm2. The proposed MCDRL was 0.23 Gy cm2, substantially higher than the recently published DRLs from other countries. The median kVp ranged from 95 to 104, while mAs ranged from 2.5 to 5.6. Large variations in the PKA and exposure parameters were observed within and among hospitals. The elevated PKA values observed in this study were mostly due to the use of high mAs in clinical practice. The weak correlation observed between patient weight and exposure parameters suggests the need to standardise examination protocols concerning patient size. The observed dose variations demonstrate the need for the establishment of national DRLs. Until then, the proposed MCDRL can be considered as the benchmark dose level for chest x-ray examinations in Sri Lanka.

30 March 2024 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
SWSachini Udara Wickramasinghe
Sachini Udara Wickramasinghe
VRVijitha Ramanathan
Vijitha Ramanathan
SSSivananthan Sarasanandarajah
Sivananthan Sarasanandarajah
MZManjuka De Zoyza
Manjuka De Zoyza
RPRoshan Paranamana
Roshan Paranamana
Ensuring the safety of healthcare workers in interventional cardiology necessitates effective monitoring of occupational radiation exposure. This study aims to assess the accuracy of the over-apron single dosimetric approach compared with double dosimetric methods and explore the relationship between under-apron and over-apron doses. This investigation showed that the prescribed annual dose constraint of 20 mSv year−1 was not exceeded by the maximum annual occupational doses determined by dosimetric algorithms, which were 0.13 ± 0.02, 0.15 ± 0.02 and 0.27 ± 0.04 mSv, respectively. The study demonstrated excellent statistically significant correlations among single and double dosimetric algorithms and between direct under-apron and over-apron doses. Consequently, single dosimetric algorithms could effectively estimate doses for double dosimetric algorithms, highlighting the limited added value of under-apron measurements. These findings significantly impact the practice of interventional cardiology in Sri Lanka, playing a crucial role in enhancing radiation protection measures.