9 February 2017 in IEEE Sensors Journal
This paper describes an optical-fiber sensor development and implementation, based on Bragg gratings, to measure the mechanical deformation at the bone surface of a bovine mandible, caused by chewing different types of food and rumination. A suitable encapsulation was developed using a titanium mesh as a transducer and sensor calibration and characterization tests were performed. The proposed sensor was deployed in a living animal transmitting the detected bone deformation to the data collecting instrument. The acquired signal was applied to a pattern-classification algorithm based on decision trees for identifying the chewing process of different foods. The results demonstrate that the sensor is effective and sensitive, capable of capturing the force generated during the masticatory process.
26 November 2014 in Journal of Lightwave Technology
AFAna Paula G. de O. Franco
Ana Paula G. de O. Franco
OGOsnara Maria Mongruel Gomes
Osnara Maria Mongruel Gomes
This study evaluated the shrinkage polymerization of two dual-curing resin cements during in vitro and in situ tests, using fiber Bragg grating with different curing time periods. The cements used were: Relyx ARC (dual conventional) and Relyx U200 (dual self-adhesive). For the in vitro experiment, the resin cements and the sensors were placed between two glass coverslips and afterwards were photoactivated for 40 s (N = 20). For the in situ experiments, 20 human teeth were prepared to receive root posts cemented with the same two resin cements. Two sensors were glued to the posts' surfaces at the coronal and apical thirds. Next, the cementation of the posts was photoactivated for 40 s. The sensors measured the strain for 60 min in both experiments. Data from in vitro and in situ experiments were analyzed by three-way ANOVA and Games-Howell multiple comparison procedures. Data from the coronal and apical thirds were analyzed by two-way ANOVA and T-test. The results showed that the polymerization shrinkage values are similar for the in vitro and in situ experiments, that contraction is greater after 5 minutes curing time compared to the contraction at 60 min, that both resin cements performed similarly and that the shrinkage measurement at the cervical third showed higher values than those at the apical third.
4 May 2016 in Journal of Lightwave Technology
This study evaluates the polymerization shrinkage of two types of acrylic resins using two methods of splinting. Two implants were placed in an artificial bone, with the two transfer copings joined with dental floss and acrylic resins. Measurements of shrinkage and temperature were performed with fiber Bragg grating sensors. The results revealed that both resins showed similar shrinkage values, although one of them also showed a higher temperature increase. The measured values demonstrated that the separation and reconnection of the splinting with acrylic resin is effective at relaxing stress polymerization and reducing shrinkage polymerization.
3 July 2019 in Journal of Lightwave Technology
This study evaluates the polymerization shrinkage of a bulk fill flow composite photoactivated by continuous or ramped irradiation. Sample teeth were prepared with Class I occlusal cavity. The fiber Bragg grating sensors are placed along bucco-lingual and mesio-distal directions for measuring the shrinkage and temperature. The results reveal that ramp irradiation protocol showed a slower evolution of shrinkage polymerization curve, but the final values of shrinkage for continuous and ramp protocols are not significantly different. The ramp irradiation protocol showed higher temperature changes than that of the continuous irradiation procedure.