Daniel Buser

Daniel Buser

Auto-generated profile, based on publicly available information

Daniel Buser

School of Dental Medicine University of Bern Bern Switzerland

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2023 in Periodontology 2000
Verified
Journal Article
Closed access
DBDaniel Buser
Daniel Buser
IUIstvan Urban
Istvan Urban
AMAlberto Monje
Alberto Monje
Marcel F. KunrathMarcel F. Kunrath
Marcel F. Kunrath
CDChrister Dahlin
Christer Dahlin

26 September 2023 in Clinical Oral Implants Research
Verified
Journal Article
Open access
SJSimon S. Jensen
Simon S. Jensen
TATara Aghaloo
Tara Aghaloo
RJRonald E. Jung
Ronald E. Jung
KBKristina Bertl
Kristina Bertl
DBDaniel Buser
Daniel Buser
GZGiovanni Zucchelli
Giovanni Zucchelli
Objectives: The aims of Working Group 1 were to address the role (i) of the buccolingual bone dimensions after implant placement in healed alveolar ridge sites on the occurrence of biologic and aesthetic complications, and (ii) of soft tissue augmentation (STA) on the stability of clinical, radiographic, and patient‐related outcomes of implant treatments.Materials and Methods: Two systematic reviews were prepared in advance of the Consensus Conference and were discussed among the participants of Group 1. Consensus statements, clinical recommendations, recommendations for future research, and reflections on patient perspectives were based on structured group discussions until consensus was reached among the entire group of experts. The statements were then presented and accepted following further discussion and modifications as required by the plenary.Results: Dimensional changes of the alveolar ridge occurred after implant placement in healed sites, and a reduction in buccal bone wall thickness (BBW) of 0.3 to 1.8 mm was observed. In healed sites with a BBW of <1.5 mm after implant placement, increased vertical bone loss, and less favorable clinical and radiographic outcomes were demonstrated. Implants with buccal dehiscence defects undergoing simultaneous guided bone regeneration, showed less vertical bone loss, and more favorable clinical and radiographic outcomes, compared to non‐augmented dehiscence defects during initial healing.At healthy single implant sites, probing depths, bleeding and plaque scores, and interproximal bone levels evaluated at 1 year, remained stable for up to 5 years, with or without STA. When single implant sites were augmented with connective tissue grafts, either for soft tissue phenotype modification or buccal soft tissue dehiscence, stable levels of the soft tissue margin, and stable or even increased soft tissue thickness and/or width of keratinized mucosa could be observed from 1 to 5 years. In contrast, non‐augmented sites were more prone to show apical migration of the soft tissue margin in the long‐term. Favorable aesthetic and patient‐reported outcomes after STA were documented to be stable from 1 to 5 years.Conclusions: It is concluded that dimensional changes of the alveolar ridge occur after implant placement in healed sites and that sites with a thin BBW after implant placement are prone to exhibit less favorable clinical and radiographic outcomes. In addition, it is concluded that STA can provide stable clinical, radiographic, aesthetic, and patient‐reported outcomes in the medium and long‐term.

15 July 2015 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
YZYufeng Zhang
Yufeng Zhang
DJDai Jing
Dai Jing
DBDaniel Buser
Daniel Buser
Anton SculeanAnton Sculean
Anton Sculean
FCFatiha Chandad
Fatiha Chandad
RMRichard Miron
Richard Miron

1 July 2017 in International Journal of Periodontics & Restorative Dentistry
Verified
Journal Article
Closed access
PBPhilip Bender
Philip Bender
GSGiovanni Salvi
Giovanni Salvi
DBDaniel Buser
Daniel Buser
Anton SculeanAnton Sculean
Anton Sculean
MBMichael M Bornstein
Michael M Bornstein
Philip Bender, Dr med dent/Giovanni E. Salvi, Prof Dr med dent/Daniel Buser, Prof Dr med dent/Anton Sculean, Prof Dr med dent/Michael M. Bornstein, Prof Dr med dent: The purpose of this retrospective radiographic study was to evaluate and correlate the dimensions and morphology of peri-implant bone defects as determined via cone beam computed tomography (CBCT) scans with regard to the selected treatment approach. Vertical and horizontal peri-implant bone defects (mesial, distal, mesio-oral, mesiobuccal, disto-oral, distobuccal, oral, and buccal) in peri-implantitis cases were measured. Three-dimensional data and defect morphology were correlated to the treatment approach chosen (explantation versus implant retention). A total of 19 patients and 28 implants met the inclusion criteria, resulting in a sample size of 224 sites and a total of 896 measurements. The mean percent bone loss did not correlate to the type of treatment chosen (P = .1286). In contrast, when only the maximum vertical values per implant were selected, maximum percent bone loss exhibited a significant correlation to the type of treatment chosen (P = .0021). The effect of the defect morphology on the treatment strategy chosen did not show a statistically significant correlation (P = .4685). Based on the data presented, the maximum bone loss around the implant seems to be a critical factor in deciding whether or not an implant should be explanted. The use of CBCT for treatment planning in cases of peri-implantitis can offer valuable additional information but should be considered only after initial clinical examination and two-dimensional imaging.

1 July 2018 in International Journal of Periodontics & Restorative Dentistry
Verified
Journal Article
Closed access
VCVivianne Chappuis
Vivianne Chappuis
KSKamal Shahim
Kamal Shahim
RBRamona Buser
Ramona Buser
EKEdi Koller
Edi Koller
Tim JodaTim Joda
Tim Joda
DBDaniel Buser
Daniel Buser
Vivianne Chappuis, DMD/Kamal Shahim, PhD/Ramona Buser, DMD/Edi Koller, DMD/Tim Joda, DMD/Mauricio Reyes, PhD/Daniel Buser, DMD: The purpose of this case series was to assess safety and feasibility of a novel resorbable collagen matrix (CMX) to enhance tissue thickness simultaneous with implant placement and guided bone regeneration (GBR) in esthetic sites over an 8-week healing period. Soft tissue thickness at implant sites and adjacent teeth was monitored with an ultrasonic device. Overall tissue contour changes were assessed by sequential digital surface model superimpositions. Periodontal parameters and patient-related outcomes revealed no significant changes. Combining a novel CMX and GBR revealed a significant soft tissue thickness increase of 1.56 mm at implant sites after 8 weeks, with no significant decrease between 4 and 8 weeks. The overall tissue contour increase was most significant at a distance of 5 mm from the mucosal margin, corresponding to a tissue increase at the implant shoulder area. No effect was observed at adjacent teeth after 8 weeks.

3 January 2024 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
JWJulia‐Gabriela Wittneben
Julia‐Gabriela Wittneben
SASamir Abou‐Ayash
Samir Abou‐Ayash
AGArdian Gashi
Ardian Gashi
DBDaniel Buser
Daniel Buser
UBUrs Belser
Urs Belser
JGJelena Gavric
Jelena Gavric