Rachel Hegeman

Rachel Hegeman

Auto-generated profile, based on publicly available information

Rachel Hegeman

Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
FAFarshid Alambeigi
Farshid Alambeigi
ZWZerui Wang
Zerui Wang
RHRachel Hegeman
Rachel Hegeman
YLYunhui Liu
Yunhui Liu
MAMehran Armand
Mehran Armand
We present an autonomous manipulation approach for tissues with anisotropic deformation behavior using a continuum manipulator. The key feature of our visionbased study is an online learning and estimation method, which makes its implementation independent of any prior knowledge about (i) the deformation behavior of the tissue and (ii) continuum manipulator as well as (iii) calibration of the vision system with respect to the robot. This important feature addresses the difficulty of using model-based control approaches in deformation control of a continuum manipulator manipulating an unknown deformable tissue. We evaluated the performance and robustness of our method in three different experiments using the da Vinci Research Kit coupled with a 5 mm instrument that has a 4-degree-of-freedom snake-like wrist. These experiments simulated situations that occur in various surgical schemes and verified the adaptability, learning capability, and accuracy of the proposed method.

31 August 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
SSShahriar Sefati
Shahriar Sefati
RHRachel Hegeman
Rachel Hegeman
FAFarshid Alambeigi
Farshid Alambeigi
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
PKPeter Kazanzides
Peter Kazanzides
MAMehran Armand
Mehran Armand
This article presents the development and experimental evaluation of a redundant robotic system for the less-invasive treatment of osteolysis (bone degradation) behind the acetabular implant during total hip replacement revision surgery. The system comprises a rigid-link positioning robot and a continuum dexterous manipulator (CDM) equipped with highly flexible debriding tools and a fiber Bragg grating (FBG) based sensor. The robot and the continuum manipulator are controlled concurrently via an optimization-based framework using the tip position estimation (TPE) from the FBG sensor as feedback. Performance of the system is evaluated on a setup that consists of an acetabular cup and saw-bone phantom simulating the bone behind the cup. Experiments consist of performing the surgical procedure on the simulated phantom setup. CDM TPE using FBGs, target location placement, cutting performance, and the concurrent control algorithm capability in achieving the desired tasks are evaluated. Mean and standard deviation of the CDM TPE from the FBG sensor and the robotic system are 0.50 and 0.18 mm, respectively. Using the developed surgical system, accurate positioning and successful cutting of desired straight-line and curvilinear paths on saw-bone phantoms behind the cup with different densities are demonstrated. Compared to the conventional rigid tools, the workspace reach behind the acetabular cup is 2.47 times greater when using the developed robotic system.

21 July 2021 in IEEE Transactions on Robotics
Verified
Journal Article
Open access
SSShahriar Sefati
Shahriar Sefati
RHRachel Hegeman
Rachel Hegeman
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
RTRussell H. Taylor
Russell H. Taylor
MAMehran Armand
Mehran Armand
This article presents a dexterous robotic system for autonomous debridement of osteolytic bone lesions in confined spaces. The proposed system is distinguished from the state-of-the-art orthopedics systems because it combines a rigid-link robot with a continuum manipulator (CM) that enhances reach in difficult-to-access spaces often encountered in surgery. The CM is equipped with flexible debriding instruments and fiber Bragg grating sensors. The surgeon plans on the patient’s preoperative computed tomography and the robotic system performs the task autonomously under the surgeon’s supervision. An optimization-based controller generates control commands on the fly to execute the task while satisfying physical and safety constraints. The system design and controller are discussed and extensive simulation, phantom and human cadaver experiments are carried out to evaluate the performance, workspace, and dexterity in confined spaces. Mean and standard deviation of target placement are 0.5 and 0.18 mm, and the robotic system covers 91% of the workspace behind an acetabular implant in treatment of hip osteolysis, compared to the 54% that is achieved by conventional rigid tools.

1 March 2022 in Field Robotics
Verified
Journal Article
Open access
RGRobert Griffin
Robert Griffin
SMStephen McCrory
Stephen McCrory
SBSylvain Bertrand
Sylvain Bertrand
DCDuncan Calvert
Duncan Calvert
ILInho Lee
Inho Lee
JPJerry Pratt
Jerry Pratt