15 September 2022 in IEEE Transactions on Energy Conversion
This paper provides analyses of subsynchronous oscillations associated with solar photovoltaics (PVs) observed in real world. All have oscillation frequencies at approximately 20 Hz in voltage and current magnitudes. On the other hand, in phase voltage and current, the oscillations show very different signatures. Through constructing simplified linear models and conducting sensitivity analysis, we are able to associate dynamic phenomena with the underlying mechanism and speculate the possible causes of the 20-Hz oscillations. The analysis results have all been validated via simulation results from electromagnetic transient (EMT) test beds constructed in MATLAB/Simscape.
18 March 2024 in IEEE Transactions on Power Delivery
This article describes a positive-sequence model to represent two widely reported droop-controlled grid-forming inverters for transmission system transient stability simulation studies. Methods of how to develop the equivalent voltage source behind impedance to represent inverters with and without inner control loops, modeling of P-f and Q-V droop controls, active and reactive power limiting modeling, and modeling of fault current limiting controls have been described in detail. The model was implemented in commercially available positive-sequence simulation tools and compared with detailed electromagnetic transient models in both a single-grid-forming-inverter infinite-bus system and a modified IEEE 39-bus system. Finally, the model was tested on the U.S. Western Interconnection system. The study results showed that the model has a good level of accuracy compared to the detailed EMT models, and at the same time also achieves a high computational efficiency, making it suitable for large-scale transmission system simulation studies.
22 November 2017 in IEEE Transactions on Sustainable Energy
Recently, through efforts lead by the Western Electricity Coordinating Council's Renewable Energy Modeling Task Force, the so-called 2nd generation generic models were developed for modeling inverter based energy sources such as wind and photovoltaic generation. These models have been industry vetted, and approved, and now reside in several commercial software platforms used throughout North America, and elsewhere in the world. The benefit of these models is their generic nature and being open and publicly available. In this paper, we present a detailed account of field testing five large wind power plants in order to build and validate the dynamic models for the plants using these generic models. Several key insights are high-lighted relative to the process and approach to model validation, including some unique circumstances for a few of these wind power plants, which are in close electrical proximity to each other. It is shown that these simplified models are able to match the field tests and yield reasonable and well-behaved models for use in large scale stability studies.
22 April 2019 in IEEE Transactions on Power Systems
One challenge in power-system control designs is the gap between numerical model-based analysis and complex real-world power systems. With increased data and measurements being collected from power systems, data-driven analysis (e.g., machine learning) may provide an alternative approach to reveal hidden information through learning from the real system data, and provide insights for better control scheme design during the utility planning process. In this study, data-driven feature analysis is performed to evaluate the relationships between series compensation, power generation, and path flows in a real transmission system, as well as temporal patterns. The main data-driven analysis methods, including statistical cross correlation, multinomial logistical regression, and classification and regression trees, are integrated for feature selection and developing predictive models of series compensation. Analysis results demonstrates the effectiveness of the proposed methodology in feature analysis and the potential to help improve power-system control scheme design.
7 July 2021 in IEEE Transactions on Energy Conversion
This article discusses the accuracy issue in applying the commonly used stator-decrement test (load rejection) method for validating generator d-axis parameters. Theoretical analysis and actual examples are provided to illustrate how the accuracy issue is related to the rotor field winding current as well as hysteresis, which has not been analyzed in detail for the second-order generator models widely used in power system studies. A generic, practical method for validating generator synchronous inductance is proposed and proven with actual field measurements and model validation study results using the GENQEC model. The generator field current compensation factor of the GENQEC model improves the field current accuracy independently of magnetic saturation. Its advantages are demonstrated in model parameter validation using field measurement results from in-service salient-pole and round-rotor synchronous generators. The proposed method with the GENQEC dynamic model can be used to establish a baseline for accurately validating generator direct-axis parameters using stator-decrement test results. The innovative method of validating generator synchronous d-axis reactance proposed in this article can be a practical and reliable alternative to the test methods provided by IEEE standards.