23 March 2022 in IEEE Transactions on Power Systems
This paper presents a survey of real-world subsynchronous oscillation events associated with inverter-based resources (IBR) over the past decade. The focus is on those oscillations in the subsynchronous frequency range known to be influenced by power grid characteristics, e.g., series compensation or low system strength. A brief overview of the historical events is presented followed by detailed descriptions of a series of events. This paper also examines causation mechanisms and proposes future research directions to meet grid needs worldwide.
15 September 2022 in IEEE Transactions on Energy Conversion
This paper provides analyses of subsynchronous oscillations associated with solar photovoltaics (PVs) observed in real world. All have oscillation frequencies at approximately 20 Hz in voltage and current magnitudes. On the other hand, in phase voltage and current, the oscillations show very different signatures. Through constructing simplified linear models and conducting sensitivity analysis, we are able to associate dynamic phenomena with the underlying mechanism and speculate the possible causes of the 20-Hz oscillations. The analysis results have all been validated via simulation results from electromagnetic transient (EMT) test beds constructed in MATLAB/Simscape.
9 January 2025 in IEEE Transactions on Power Systems
The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. This letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter
6 May 2019 in IEEE Transactions on Power Delivery
This paper presents a new series capacitor based frequency scan method to assess the Subsynchronous Resonance (SSR) risk including Induction Generator Effect (IGE) and Subsynchronous Control Interaction (SSCI). Most existing frequency scan methods are generator based and calculate the impedance as viewed from the neural bus of the study generator. In this paper, the generator based frequency scan method is discovered to be inadequate or inapplicable to deal with a cluster of inverter based generation resources under some circumstances. The proposed method scans the impedance as viewed from the series capacitor to assess the IGE/SSCI risk. With nearby inverter based generation resources modeled by their frequency dependent impedances, the proposed method is capable of assessing the IGE/SSCI risk for a cluster of inverter based generation resources. The Electro-Magnetic Transient (EMT) simulation was conducted to validate the proposed method. The proposed method also successfully demonstrates the non-linear impact of the number of in-service units on the SSCI performance for a cluster of inverter based generators.
22 May 2024 in IEEE Transactions on Power Systems
Sustained oscillations persist without decay, impacting system stability and performance. Sustained oscillations in distribution systems exhibit unique mechanisms compared to those in transmission systems, yet research in this area of distribution systems is lacking. In distribution systems, these oscillations degrade power quality, jeopardizing stability and causing relay malfunctions and supply discontinuity. Understanding their mechanisms in modern distribution systems is crucial for their detection, classification, and localization. This paper provides a comprehensive review of sustained oscillations in modern distribution systems. Additionally, it discusses key methodologies for detecting and classifying sustained oscillations in transmission systems. Finally, it applies transmission system methodologies to real cases in Ontario's distribution system, shedding light on challenges and future directions.
20 August 2025 in IEEE Power and Energy Magazine
ERCOT, the independent system operator (ISO) for the Texas region, USA, continuously assesses the reliability of its grid. With the increase of large loads interconnecting to the electric grid, including large data centers and crypto mining centers, maintaining grid reliability can become more challenging depending on the size of the load, its geographical location, its ramping controls, and network conditions. Further, a load’s lack of voltage ride-through (VRT) capability or frequency ride-through (FRT) capability could degrade system reliability. Additionally, these loads could introduce new vulnerabilities to sub-synchronous oscillations (SSO) or sub-synchronous control interactions (SSCI). This article will review realistic critical scenarios that require planning or operation level studies to assess reliability. These assessments will consider VRT and FRT tests with updated models, evaluations of large load on regions with known stability constraints, system impact of co-located load with generation, SSO/SSCI vulnerabilities and other similar reliability challenges.