17 March 2025 in Physical Review Letters
This Letter reports on the first cross-section measurements for the ^{94}Sr(α,n)^{97}Zr and ^{86}Kr(α,n)^{89}Sr reactions. In particular, our measurement of ^{94}Sr(α,n)^{97}Zr is the first weak r-process reaction cross section obtained using a radioactive ion beam. This experiment was enabled by the use of novel solid helium targets, comprised of silicon thin films with high helium incorporation obtained via a sputtering technique. Yield measurements were performed at center-of-mass energies of 10.4 and 9.0 MeV for the ^{86}Kr(α,n)^{89}Sr reaction, and 9.9 MeV for ^{94}Sr(α,n)^{97}Zr, extending into the respective Gamow energy windows for a temperature of 5 GK. Reactions were uniquely identified by prompt γ rays detected in coincidence with heavy ions selected by a recoil mass spectrometer. The obtained cross sections are smaller than predicted for both reactions. In the case of ^{94}Sr(α,n)^{97}Zr, the reaction rate found here is lowered by an order of magnitude at temperatures below 5 GK, which is expected to impact the predicted abundance of ruthenium, a signature weak r-process element.
18 July 2025 in Physical Review C
13 September 2024 in Physical Review C
24 November 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
26 April 2026 in Physics Letters B
28 February 2024 in IEEE Transactions on Nuclear Science
Detecting emitted radiation from nuclear processes such as reactions and radioactive decay allows for probes of the not-so-well understood nuclear interaction, a residual of the strong interaction which acts on quarks and gluons rather than protons and neutrons. Employing multi-detector systems as opposed to single-detector systems increases the breadth of studies which can be performed both by increasing the overall efficiency and by using time-correlated measurement techniques. With multi-detector systems, however, comes an increase in complexity, size, power consumption, and cost for data acquisition systems which can process and perform logical operations on raw signals. To combat this in the Nuclear Science Laboratory at Simon Fraser University, real-time event filtering has been implemented using a user programmable logic module called XLM72S. The logic module provides 72 emitter-coupled logic ports, configurable quartet-wise as inputs or outputs, an on-board 80 MHz clock, four digital clock managers capable of synthesizing additional clock frequencies, and two serial peripheral interface memories. In the current setup, the XLM72S allows for simultaneous and computer controlled logic to be performed on up to 20 Compton Suppressed Spectrometers used for the detection of gamma rays from nuclear decays, as well as up to 4 auxiliary signals used for filtering events which have coincident particle emission. The XLM72S module has been implemented and tested for a system containing five Compton Suppressed Spectrometers and a charged particle detector, demonstrating it’s effectiveness at performing logic in real time for anti-coincident Compton Suppression and coincidence multi-fold events.