Yueming Sun

Yueming Sun

Auto-generated profile, based on publicly available information

Yueming Sun

Victoria University of Wellington

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2021 in Superconductor Science and Technology
Verified
Journal Article
Closed access
YSYueming Sun
Yueming Sun
JFJin Fang
Jin Fang
GSGennady Sidorov
Gennady Sidorov
QLQuan Li
Quan Li
RBRodney Badcock
Rodney Badcock
ZJZhenan Jiang
Zhenan Jiang
In many high-temperature superconducting (HTS) applications, HTS coated conductors carry DC currents under external AC magnetic fields. There are two AC loss mechanisms in this situation: magnetization loss due to the external magnetic field and dynamic loss due to the interaction between the DC current and the external magnetic field. The sum of these two loss components is referred to as total loss. In this work, the total loss in a 4 mm wide REBCO coated conductor is measured under perpendicular AC magnetic fields up to 105 mT at 77 K, 70 K, and 65 K, with reduced DC current level, i ( I dc / I c0 ), from 0.025 to 0.98, where I dc is the transport DC current value and I c0 is the self-field critical current of the coated conductor at each temperature. The experimental results show a good quantitative agreement with an analytical equation for each loss component, as well as 2D finite element modelling (FEM) results from H -formulation. For any given temperature, we observe that the total loss is mostly dominated by magnetization loss at i < 0.2, while dynamic loss makes a comparable, even greater contribution to total loss at i > 0.5. Electromagnetic analysis from the FEM modelling shows the evolution process of total loss, where the dynamic loss region and magnetization loss region vary across the conductor width at high magnetic fields or high DC current level. The simulation results also reveal the superposition of (positive) DC current and the anti-parallel (negative) shielding current, which occurs at high DC current level. The superposition drives the current density of one conductor edge to subcritical stage, and it leads to one-sided loss generation in each half-cycle. Our results provide a valuable reference for total loss behaviours in REBCO coated conductors.

24 February 2023 in Superconductor Science and Technology
Verified
Journal Article
Open access
PDF file
YSYueming Sun
Yueming Sun
SYShuangrong You
Shuangrong You
RBRodney Badcock
Rodney Badcock
NLNicholas Long
Nicholas Long
ZJZhenan Jiang
Zhenan Jiang
In many high-temperature superconducting applications, REBCO (Rare-earth barium copper oxide) coils carry DC currents under AC magnetic fields, such as the field winding of rotating machines, linear synchronous motors and the electro-dynamic suspension system of maglev. In such operating conditions, REBCO coils generate AC loss—total loss which includes the magnetization loss due to the shielding currents, and the dynamic loss arising from dynamic resistance caused by the interaction of DC currents and AC magnetic fields. In this work, dynamic resistance and total loss in a small double pancake coil (DPC) and a small double racetrack coil (DRC) are investigated via experiments in the temperature range between 77 K and 65 K. The DC currents are varied from zero to 70% of the self-field critical currents of the REBCO coils, with AC magnetic fields up to 100 mT. The experimental results in the DPC are well supported by the finite element simulation results using 3D T-A formulation. Our results show that the critical current of the DRC is approximately 2%–5% higher than that of the DPC in the temperature range. For given experimental conditions, the magnetization loss in both coils is much greater than the dynamic loss. The dynamic loss and magnetization loss in the DRC are greater than those in the DPC, which we attribute to the large perpendicular magnetic field component in the straight sections of the DRC.

8 February 2022 in Superconductor Science and Technology
Verified
Journal Article
Closed access
YSYueming Sun
Yueming Sun
JFJin Fang
Jin Fang
GSGennady Sidorov
Gennady Sidorov
RBRodney Badcock
Rodney Badcock
NLNicholas J Long
Nicholas J Long
ZJZhenan Jiang
Zhenan Jiang
In many high-temperature superconducting (HTS) applications, HTS-coated conductors carry a DC current under an external AC magnetic field. In such operating conditions, dynamic resistance will occur when the traversing magnetic flux across the HTS conductors. Consequently, AC loss within the superconductors is composed of the dynamic loss component arising from dynamic resistance and the magnetization loss component due to the AC external magnetic field. This AC loss is one of the critical issues for HTS applications, such as persistent current switches, flux pumps, and rotating machines. In this work, the dynamic resistance and the total loss in a three-tape HTS coated conductor stack were measured at 77 K under perpendicular AC magnetic fields up to 80 mT and DC currents (I dc) up to the critical current (I c). The stack was assembled from three serial-connected 4 mm wide Superpower wires. The measured dynamic resistance results for the stack were well supported by the results from 2D H-formulation finite element modelling (FEM) and broadly agree with the analytical values for stacks. The FEM analysis shows asymmetric transport DC current profiles in the central region of the superconductor. We attribute the result to the superposition of DC currents and the induced subcritical currents which explains why the measured magnetization loss values increase with DC current levels at low magnetic field. The onset of dynamic loss for the stack for low i (I dc/I c) values is much slower when compared to that of the single tape and hence the contribution of the dynamic loss component to the total loss in the stack is much smaller than that of the single tape. Dynamic loss in the stack becomes comparable to the magnetization loss at i = 0.5 and becomes greater than the magnetization loss at i = 0.7. Both magnetization loss and dynamic loss in the stack are smaller than those of the single tape due to shielding effects. The difference between the Q total behaviours in the stack and single tape is due to the variation of the penetration depths of the stack and single tape at the different magnetic field amplitudes.

23 August 2021 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
YSYueming Sun
Yueming Sun
JFJin Fang
Jin Fang
APAndres E. Pantoja
Andres E. Pantoja
RBRodney Badcock
Rodney Badcock
NLNicholas Long
Nicholas Long
ZJZhenan Jiang
Zhenan Jiang
Commercial high-Tc superconducting (HTS) coated conductors exhibit asymmetric Ic(B,θ) characteristics, where B presents a DC magnetic field and θ is defined as the angle between an applied magnetic field and the normal component of the superconductor plane. The asymmetric Ic(B,θ) characteristics have a non-trivial influence on the dominant loss component, magnetization loss, of various HTS applications where HTS conductors are exposed to an AC magnetic field. Here, we present measurements of Ic(B,θ) and magnetization loss in a 12 mm-wide (Rare Earth)Ba2 Cu3 O7−d (REBCO) commercial coated conductor at 77, 70, and 65 K. In the Ic(B,θ) measurement, θ was varied around a full 360° revolution and B was varied up to 0.2 T. In terms of the magnetization loss measurement, the applied AC magnetic field amplitude is up to 110 mT and the field angle varied from 0° to 180° . At the three given temperatures, we observed magnetization loss variations among the field-angle range, in particular, for θ and 180° -θ , which are in mirror symmetry relative to the superconducting plane. Furthermore, this asymmetric field-angle dependence of the magnetization loss becomes more apparent at higher applied field amplitudes and lower operating temperatures. A finite element method simulation using H-formulation was carried out by directly interpolating the measured Ic(B,θ) data, and the simulation results reproduce the trend of the experimental results. We also found that the magnetization loss is not equivalent within the positive and negative half field cycles due to the asymmetric Ic(B,θ) characteristics of the conductor. Numerical simulations revealed a clear correlation between the magnetization loss and the asymmetric Ic(B,θ) data for the whole 360° field-angle range in the REBCO conductor. The asymmetry in the Ic(B,θ) data about the ab-peak causes differences in magnetization loss values for the mirror-symmetric field angles. The asymmetry in the Ic(B,θ) data upon field reversal also results in differences between magnetization loss values for the positive and negative cycles.

27 July 2020 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
YSYueming Sun
Yueming Sun
NLNicholas Long
Nicholas Long
GSGennady Sidorov
Gennady Sidorov
JFJin Fang
Jin Fang
RBRodney Badcock
Rodney Badcock
ZJZhenan Jiang
Zhenan Jiang
(RE)Ba 2 Cu 3 O 7 -d (REBCO) coated conductors are becoming a preferred wire choice for many potential high temperature superconducting (HTS) applications, where additional metal layers are usually attached to the REBCO conductors to improve reliability and stability. In such cases, the eddy current loss in the metal layers is affected by the magnetic field shielding by adjacent REBCO coated conductors. Here we present the ac loss measurement and simulation results in three copper-superconductor stacks comprising a 10-mm-wide Fujikura-coated conductor with one, two, and four 0.1-mm-thick, 10-mm-wide copper strips, under various applied magnetic field angles (defined by the angle between the applied magnetic field and the wide face of the superconductor) from 15° to 90° at 77 K. The amplitude of the magnetic field is up to 100 mT. The shielding effect, which reduces the eddy current loss in the metal layers stacked with a superconductor layer, increases with decreasing field angles, due to the change of the effective penetration field at the different field angles. The eddy current loss in the copper strips in the copper-superconductor stacks under the magnetic fields with various orientations is dominated by the perpendicular magnetic field component.

28 July 2023 in Superconductor Science and Technology
Verified
Journal Article
Open access
YSYueming Sun
Yueming Sun
JGJianzhao Geng
Jianzhao Geng
RBRodney Badcock
Rodney Badcock
ZJZhenan Jiang
Zhenan Jiang
The dynamic resistance of REBCO (REBa2Cu3O7-d, RE stands for rare earth), coated conductors (CCs) is a key parameter in many high-temperature superconductor applications where CCs carry DC currents exposed to AC and DC magnetic fields, such as field-triggered persistent current switches, flux pumps, and fault current limiters. In this work, dynamic resistance and dynamic voltage have been studied via experiments and finite element method (FEM) simulations in a REBCO bifilar stack at 77 K, under combined AC and DC magnetic fields with different magnitudes, frequencies, and waveforms. Our results show some distinct features of dynamic resistance and voltage from those under pure AC magnetic fields. With an increasing DC magnetic field, the dynamic resistance exhibits an obvious linearity with the applied AC magnetic field, and becomes less dependent on the AC field frequency. The fundamental frequency of the dynamic voltage under a DC magnetic field becomes the same as that of the applied AC field, which completely differs from the pure AC field case where the fundamental frequency doubles. For the first time, instantaneous threshold field (B th) values are obtained from the dynamic voltage, which are substantially different in the field-increasing and field-decreasing processes. These key differences are attributed to the dominant role of DC magnetic fields in determining the critical current of the superconductor, which significantly dwarfs the influence of AC fields. These new discoveries may help researchers better understand the electromagnetism of superconductors and be useful for relevant applications.